Loading...
HomeMy WebLinkAboutCC Res 5211 2004-02-23 1 I 1 RESOLUTION NO. ~ / / A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SEAL BEACH APPROVING STANDARD PLANS FOR SEWER FACILiTIES, 2004 EDITION WHEREAS, The Public Works Department of the City of Seal Beach has presented to the City Council a certain publication which is desired by the Public Works Department to be used in the design and construction of sewer facilities within the City of Seal Beach; and WHEREAS,' Said publication is the Standard Plans for Sewer Facilities, 2004 Edition; and WHEREAS, The City Council desires to approve said publication as the minimum standard to be followed for the design and construction of sewer facilities within the City of Seal Beach and for projects requiring a Public Works Pennit; and to authorize the Director of Public Works/City Engineer to make changes to said publication as required by new regulations, for improvements to the sewer infrastructure, and for the protection of public health and safety; NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF SEAL BEACH DOES HEREBY RESOLVE, DECLARE, DETERMfNE AND ORDER AS FOLLOWS: SECTION 1. AdoDtion, adopts said publication as the ininimum standard to be followed for the design and construction of sewer facilities with the City of Seal Beach, SECTION 2, Authorization. Authorizes the Director of Public Works/City Engineer to make changes to said publication as required by new regulations, for improvements to the sewer infrastructure, and for the protection of public health and sa1t:ty, PASSED, APPROVED AND ADOPTED by the City C~ the City of Seal Beach at a meeting thereof held on the ~~ day of b~, 2004 by the following vote: AYES: Couneilmember NOES: Councihnembers ABSENT: Couneilmel11.bers ~qf;J~~ f~ Mayor STATE OF CALIFORNIA COUNTY OF ORANGE CITY OF SEAL BEACH ) ) SS ) I, Joalme M. Y co, City Clerk of the City of Seal Beach, California, do hereby certify that the foregoing resolution is an original copy of Resolution Number 5:2../1 on file in the Office of the 'ty Cferk, passed, approved and adopted by the ~~leil of the City of Seal Beach at a m etin thereaf Id on the I day of 'hAA 1-,2,004. Resolution Number .5:2// Otr*S'~~= Public Works 1 STANDARD PLANS for SEWER FACILITIES 1 FEBRUARY 2004 EDITION The following Standard Plans have been adopted by the City of Seal Beach as a guide for standardization of "Public Works. within the City and have been prepared for the guidance of engineers, contractors and developers who have an interest in the preparation of plans and construction of facilities and improvements under the jurisdiction of the City of Seal Beach. Standard plans are to be used in conjunction with the currently adopted edition of the Standard Specifications for Public Works Construction, any adopted supplements or Department amendments as well as any adopted Design Criteria/Manuals and Master Plans, Conformance with these standards will~redtl~design costs and the processing time needed to review and approve plans, The~.~ liohn,te.Ad'ed to be a substitute for professional engineering knowledge, experience or judgm'E!rit..Any deviatiJRs from what is contained in the following documents must be approved in ~filihg'bY thei.Elire9tbr\of Public Works/City Engineer, These standards may be mod!fied from fl!1~{ t~e.l~~ r~iiiJi~ed, Please visit the Department website at www.sb- Dubllcworks,com\to,cbeek-for. mew'or"\Jp.dated standards, ~-S~.Q.. ~ ~ ~. I Douglas ,&i:UIRCS; ~~E~' Director of Public Works/City Engineer J :1'" .,~~ . t."... 1 1 *,1.'::;:, Resoluti~n Number 5J./ / SEE SBSD STD, DWG, S-4 FOR FRAME '" COVER DETAILS WARNING SIGN ~-C-3250 CONCRETE W 4" MAX, SLUMP E CAST IN PlACE MONOLITHICALLY 2" SLOPE R = 4" BASE POURED AGAINST UNDISTURBED SOIL IF DISTURBED OR GROUND WATER, CRUSHED NOTES: ~~f~IF~~\tl~~D PER 1, PlACE lWO HALF MOON SHAPED PLYWOOD COVERS ( 5/8" THICK MINIMUM ) IN BOTTOM OF MANHOLE AFTER SHAFTS HAVE BEEN SET TO KEEP DEBRIS FROM ENTERING SEWER, 2. FOR DROP MANHOLE SEE SBSD STD, DWG, S-13, 3, FOR MANHOLES LOCATED OUTSIDE PAVED AREAS, THE FRAME AND COVER SHALL BE SET A MINIMUM OF 0,1 FT, ABOVE FINISH GRADE IN SHOULDER AREAS, UNPAVED ROADS OR LANDSCAPED AREAS, AND 18" IN UNFINISHED AREAS, 4. ALL INLETS AND OUTLETS SHALL BE SUPPORTED WITH CONCRETE SUPPORTS PRIOR TO POURING MANHOLE BASE, 5, MANHOLE LOCATIONS SHALL BE MARKED ON CURB FACE, DRAWING-MANHOL~ DETAILS ST925R~_ fLAN REVISIONS SUPEReEOES REFERENCES DESCRIPTIONS 2" A.C, PAVEMENT~ 12' IN UNPAVED AREAS TOP OF PAVEMENT OR EXIST, GRADE PRECAST ECCENTRIC . CONCRETE CONE, ORIENT PER SBSD SID, DWG, S-3 .4 pve UNER (IF REQ'D) I ~ ~ I. ci d '" a. ii: !Z '" . :E .... ~~ '" . Ii: "'0 .. ~:E ..: :Z z w :i 0:: . ~~ 0 I "'0 ;... '0::- ~ 0.0 6' ~ ::0 ,lIIMIN, . ~. 00'" I "'I;; - So:: ...."'0 ZZ 0 ~o en '" ;;; 8" " ~, ,. II . '" + I 48" MIN, . o I "4 SEAL BEACH SEWER DEPARTMENT STANDARD REVIEWED PUBLIC Q NO. DEPUTY CITY ENGtNEER-RCE 61521 APPRCMIl D1RECTOft OF PUBUC WORKS-RCE 57202 DRAWN BY: RC HEeKED BY: BZ WORKS 10" MIN. EXIST, A.B. , EXIST, A,C, PAVEMENT 470-C-2500 CONCRETE W/4" MAX SLUMP COLLAR AROUND MANHOLE COVER FRAME, CIRCUlAR COLlAR IN PAVED AREAS, SQUARE COLlAR IN UNPAVED AREAS, IN PAVED AREAS. MANHOLE SHALL BE RAISED TO GRADE AND CONCRETE COLlAR POURED AFTER FINAL SURFACE COURSE IS PlACED, WATER TIGHT JOINTS. SEE JOINT DETAILS SBSD SID, DWG, S-2 ALL PRECAST MANHOLE SECTIONS SHALL BE MANUFACTURED IN ACCORDANCE WITH SPECIFICATIONS 1" SLOPE ,THE CROWN ELEVATION OF STUB SHALL MATCH CROWN OF MAIN LINE SEWER INSTALL STOPPER IN STUB INSTALL lWO l-FT JOINTS AT INLETS AND OUTLETS IF USING VCP SHml0rl C:\CII\'STD\S1DS-I REV 08-01-97 Resolution Number ~JI PIPE SHAll BE LAID WfTH END SQUARE INTO M,H, BASE, UNLESS OTHERWISE NOTED, REMOVE TOP PORTION Of PIPE, THEN CONSTRUCT fiLLET SHElf OVER PIPE TO DRAIN fOR LOCATION Of M,H, SHAfT OPENING SEE SBSD STD, DWG. S-J M,H, STATIONING 0,10' MIN, fALL ACROSS M,H, (1YP.) UNLESS SEWER SLOPE GREATER, 0,20' MIN, fALL fOR 9e1'M,H. r--- ....., - --r I I I I I I I I I I I PLAN ~,.... '.~ ,",: '. .......1. . , , JOINT SEALING COMPOUND , . ...;' ..": :~ .';.;:~ . ~ .' ~. PLASTIC JOINT MORTAR JOINT SEE SBSD STD, DWG. S-5 fOR PVC PIPE CONNECTION DETAILS 1 R-2XD STUB (1YP.) 8. MIN, CONC, ENCASEMENT (INCLUDING BEll) 2-1' JOINTS AT BOTH INLETS AND OUTLETS fOR VCP ONLY. ~ o ~ I . ~ - t NOTES: 1, MORTAR JOINTS - SUFfICIENT MORTAR SHAll BE APPLIED ACROSS ENTIRE FACE OF JOINT SO THAT WHEN PRECAST UNITS ARE PLACED ON TOP OF ONE ANOTHER, THE MORTAR WILL SQUEEZE OUT BOTH THE INSIDE AND OUTSIDE WALL FACES, JOINTS SHALl BE .POINTED UP. AFTER SETTING PRECAST UNITS EXCLUDING GRADE RINGS, 2. PLASTIC JOINTS - PERFORMED COLD-APPLIED READY-TO-USE PLASTIC JOINT SEAliNG COMPOUND SHALL BE QUICK-SEAL PS SUPPLlEO BY QUIKSET UTILITY VAULTS, SANTA ANA, CALIFORNIA - OR APPROVED EQUAL, MUST BE USED WHEN GROUND WATER IS ENCOUNTERED. REVIEWED SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-CONCRETE BASE AND JOINT DETAILS STANDARD PLAN 925 $-2 DEPUTY CfTY ENGINEER-RCE 81527 AI'PRllIom PUBLIC Q NO. REVISIONS DESCRIPTIONS DIRECTOR OF PUBUC WDRKS-RCE 57202 DRAWN BY: RC HECKED BY: BZ WORKS SUPEReEDES REFERENCES 1 SHEET 1 OF 1 C:\CITYSID\SlDS-2 REV 08-01-87 1 I I Resolution Number 4Jz// M,H. SHAFT OPENING (TYP,) SUMMIT M.H. (ONLY) EITHER SIDE DEPUTY CRY ENGINEER-RCE 81527 APPROVED SUMMIT M,H. (ONLY) t DIRECTOR OF PUBUC WDRKS-RCE 572D2 DRAWN BY: RC ECKED BY: BZ -- t SUMMIT M.H, (ONLY) 1M( POSITION REVIEWED SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-MANHOLE SHAFT LOCATION DETAILS PUBLIC Q REVISIONS DESCRIPTIONS NO. WORKS STANDARD PLAN '925 5-3 SUPERCEDES REfERENCES SHEET , OF 1 c:\cmsm\Sl\lS-3 REY, OB-01 -97 Resolution Number ~II 1 l' THRU HOLE SQUARE BLOCK OR DIAMOND TREAD A B ,,-- v C A E SECTION A-A 24" 34" 29" 23 ~. SIZE A B C D E 4' 6" 1. 4B" MANHOLES SHALL HAVE 24" COVERS, 60" MANHOLES SHALL HAVE 30" COVERS, 72" MANHOLES SHALL HAVE 36" COVERS, WHERE FRAME AND COVER ARE SET lB" ABOVE GRADE, FOUR (4) ~. DIA. INSERTS FOR ADJUSTABLE STUDS SHALL BE CAST IN TOP GRANDE RING, ALIGNED AS DETAILED ABOVE, FRAME SHALL BE BOLTED TO GRADE ~ING, 2, 1 1 /4" LIFTING SLOT (PICK HOLE) A FOUR !J(," DIA HOLES DRILLED '':I FRAME TO ACCEPT ~ ADJUSTABLE STUD FOR GRADE RING, SEE NOTE 2 BELOW. 1 o 30" 36" 3B" 44" 33" 39" 30" 36" 6" 6" 4" 4" STANDARD PLAN SEAL BEACH SEWER DEPARTlIENT STANDARD DRAWING-TRAFFIC MANHOLE FRAlIE AND COVER 925 5-4 RBIIEWED REVISIONS DESCRIPTIONS DEPUTY a1Y ENGINEER-RCE 61527 ~ PUBLIC ~ NO. DIRECTOR OF PUBUC WORKS-RCE 57202 DRAWN BY: RC HECKED BY: BZ WORKS SUPEReEDES REfERENCES 1 SHEET 1 OF 1 C:\CIMml\ST1lS-4 REV, 08-0,-97 Resolution Number s::z// PIPE ZONE 12" lAIN. SACK SLURRY . " I ~ PAVElAENT ZONE -, STREET 1S" ZONE TRENCH ZONE , 6" MIN. " s" MAX.ON EACH SlOE OF PIPE (lYP.) 100-E-100 SLURRY 3/4" MAX. CRUSHED ROCK PIPE SUSGRADE PIPE BASE PIPE FOUNDATION FOR UNSTABLE SOIL -SEE NOTE 2 4" lAIN. -6", s" &< 10" PIPE 6" lAIN. - 12" PIPE AND LARGER A NORMAL BEDDING I M.H. lA.H. COUPLING COUPLING GASKET TAPER PIPE AT SPIGOT FILL WITH GROUT P.V.C. PIPE MANHOLE BASE A .fJ.AM SECTION A A NOTES: MANHOLE CONNECTION DETAILS 1. CONCRETE ENCASEMENT PER SBSD STD. DWG. S-1 0 SHALL BE USED WHERE THE TRENCH WIDTH AT THE UPPER LIMIT OF THE PIPE ZONE EXCEEDS THE MAX. WIDTH SPECIFIED ABOVE. 2. IF UNSTABLE SOIL IS ENCOUNTERED, CrTY REPRESENTATIVE SHALL DETERlAlNE DEPTH OF REMOVAL AND SIZE OF FOUNDATION ROCK REFILL MATERIAL. 3. SEE SBSD STD. OWGS. S-1 &< S-2 FOR lAANHOLE DETAILS. I STANDARD PLAN SEAL SEACH SEWER DEPARTMENT STANDARD DRAWlNG-P.V,C. PIPE SEDDING Ii: SPECIAL DETAILS 925 5-5 REVIEWED PUBUC REVISIONS SUPERCEDES REfERENCES ..= _ _~._ Q ". DESCRIPTIO"' DIRECTOR OF PU8UC WORKS-Ref 57202 DRAWN BY: RC CHECKED BY: BZ WORKS SHEET 1 or 1 ~_.IJ8.oOt.., Resolution Number ~II ~ PROPERTY LINE I I VARIES LOCATE LATERAL WITH 1-1/2" HIGH "s" CHISELED IN FACE OF CURB WHERE THE LATERAL CROSSES UNDER THE CURB OR ON EDGE OF CONCRETE ALLEYS IN OLD TOWN. I TYPICAL SIDEWALK .' Z :i '" Z :i ;.. WYE BRANCH 1/8 BEND 1/4" PER FT, OR 2.0:r: BEDOING PER SBSD STD. DWG. S-8 OR S-S ___ RISER PIPE RISER PIPE I / PLASTIC STOPPER PLASTIC CAP ..-- JOINT COUPLING 1'- W/S.S. BANDS OPTIONAL STOPPER DETAILS NOTES: 1. LATERAL SIZE TO BE DETERlAlNED ON THE BASIS OF TOTAL NUlABER OF FIXTURE UNITS DRAINED, BUT IN NO CASE SHALL THE LATERAL DIAMETER BE LESS THAN FOUR INCHES FOR SINGLE OR MULTIPLE FAMILY RESIDENTIAL AND SIX INCHES FOR COlAMERCIAL OR INDUSTRIAL LAND USES. 2. LATERAL TO BE INSTALLED TO PROPERTY LINE. 3. IF RISER NOT BUILT, PLUG WYE BRANCH WITH STOPPER. SEAL BEACH SEWER DEPARTlAENT STANDARD DRAWING-VCP OR PVC TYPICAL LATERAL STANDARD PLAN 925 5-6 REVIEWED PUBUc Q NO. REVISIONS DESCRIPTIONS SUPERCEDES REfERENCES DEPUTY CRY ENGINEER-Ref 61527 APl'RD\IED I DIRECTOR Of PUBUC WORKS-Ref 57202 DRAWN BY: RC HECKED BY: BZ WORKS SHEET 1 or 1 C:\CITYS1D\STDS-6.DWG REV. 08-01-97 52// Resolution Number I MllE; THE BELL ON THE COLLAR WYE SADDLE SHALL NOT BE ENCASED IN CONCRETE. TAP TO BE MADE AT APPROX. CENTERLINE OF JOINT. CERAMIC WELD OR BANDED RUBBER COUPLING ""T -T I (~... . I 11. .:7'.""- 11 _ : f-L-----I+- ---- II 11 " " ...11-_----:...JL <1 I ..do <i......-.-"':d"" 6" lAIN.-j CONC. ENCASEMENT ~~"'1i.&:OgLUlAP SECTION A-A / 6" MI4 A 6" lAIN. CUT IN WYE , CLAY OR PVC B &< UP CONNECTION BY STD MANHOLE NOTES: 1. THE SADDLE CONNECTION SHALL BE SECURED WITH 470-C-2S00 W /4" lAAX SLUlAP CONCRETE ENCASEMENT AFTER THE CONNECTION IS APPROVED BY THE CITY REPRESENTATIVE. 2. ALL CHIPS, DIRT, EPOXY, lAORTAR, AND CONCRETE SHALL BE KEPT OUT OF THE SEWER, 3. DAMAGED PIPE SHALL BE REPLACED. STANDARD PLAN SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-CUT IN WYE CONNECTION 925 5-7 REVIEWED PUBUC G) NO. REVISIONS DESCRIPTIONS SUPERCEDES REFERENCES I DEPUTY CITY ENGINEER-RCE 61527 "".ROIIED DIRECTOR Of PUBUC WORKS-RCE 57202 DRAWN BY: RC CHECKED BY: BZ WORKS SHEET 1 or 1 C:\CITYS1D\STDS-7.DWG REV. 08-01-97 Resolution Number ~II J:IJ) U'" z- ll!~ .... 12" MIN. P.C.C. OR A.C. W/A.B. SACK SLURRY PAVElAENT ZONE , ~~ ~ I ~ o..~ t Cb.-. 00..... ~. Cb... oq.... ~. 0.. ~ \' 0.. :t Cb.~ . ~ o % Z Q,.~ ~ ~ PIPE 0.0. " SEE NOTE 1. 12" SAND OVER PIPE SE 30 lAIN. o 12" o Cb. ~ ~ .... ~ J:)"'f'(,' 0.0; ~... oq..... ~. " I I, , 1 SACK SLURRY TO UNDISTRUBED SOIL ~ ~ c:i o PIP~ ~BGBt-.Q.E ;>,t .., "'''' "'.... 000 z PIPE BASE ~I ~, Jo, ~ 3/4" lAAX. I ~ I CRUSHED ROCK ~ r ----~ FOR UNSTABLE SOIL ~1--L-------i CONDITION SEE NOTE 4 ~ PIPE FOUNDATION 4" MIN. 6", S" &< 10" PIPE 6" MIN. 12" PIPE AND LARGER. I TYPICAL NORMAL BEDDING OVERWIDTH BEDDING NOTES: 1. TRENCH WIDTH AT THE UPPER LIMIT OF THE PIPE ZONE SHALL BE WITHIN THE FOLLOWING LIMIT FOR TYPICAL NORMAL BEDDING. (A) MAXIMUM TRENCH WlDTH-O.D. PIPE OR BELL PLUS s" MAX. EACH SIDE OF PIPE. (B) MINIMUlA TRENCH WIDTH-O.D. PIPE OR BELL PLUS 6" lAIN. EACH. SIDE OF PIPE. 2. OVERWlDTH BEDDING SHALL BE USED WHERE THE TRENCH WIDTH AT THE UPPER L1lAIT OF THE PIPE ZONE EXCEEDS THE lAAXllAUM WIDTH SPECIFIED ABOVE. 3. MAXIMUM OVERWIDTH BEDDING TO BE DETEMINED IN FIELD BY THE CITY REPRESENTATIVE ON THE BASIS OF OVERWIDTH EXCAVATED. 4. IF UNSTABLE SOIL IS ENCOUNTERED. CrTY REPRESENTATIVE SHALL DETERMINE DEPTH OF REMOVAL AND SIZE OF FOUNDATION ROCK REFILL MATERIAL. SEAL BEACH SEWER DEPARTlAENT STANDARD DRAWING-V.C.P. PIPE BEDDING DETAILS STANDARD PLAN 925 5-8 NO. REVISIONS DESCRIPTIONS SUPERCEDES REFERENCES REW:WED PUBLIC G) I DEPUTY CITY ENGINEER-RCE 61527 APl'RD\IED DIRECTOR OF PUBUC WORKS-RCE 57202 DRAWN BY: RC HECKED BY: BZ WORKS SHEET 1 OF 1 C:\CITYS1D\STDS-8.DWG REV. 08-01-97 I I I Resolution Number ~"I .. A.C. PAVEME7 TOP OF GROUND CAST IRON C MARKING 3/4" DIA. HOLE 470-8-2500-'/ W/4" MAX SLUMP CONCRETE COLLAR (ROUND) . . 470-B-2S00 W/4" MAX slUlAP CONC. COLLAR (SQUARE) GRASS AREA It I PAVED AREA SEE SBSD S-S AND S-B FOR BEDDING REQUIRElAENTS 1/8 BEND .. ~ PLUG END WITH STOPPER UNDISTURBED SOIL ELEVATION QJ: zl:; '" I=~ NOTES: SECTION A - A 1. CLEANOUT PIPE TO BE SAME SIZE AND KIND OF MATERIAL AS MAIN. SEAL BEACH SEWER DEPARTMENT STANOARO ORAWING-TERMINAL OR MAIN CUEANOUT DETAIL STANDARD PLAN 925 5-9 REVIEWED PUBLIC Q NO. REVISIONS DESCRIPTIONS SUPERCEDES REFERENCES DEPUTY aTY ENGINEER-RCE 61527 APPIIO\IED DIRECTOR OF PUBUC WORKS-ReE 572D2 DRAWN BY: RC HECKED BY: BZ WORKS SHEET 1 OF 1 C:\CITYS1D\STDS-9.DWG REV. 08-01-97 Resolution Number ~// TRENCH WIDTH 6" MIN. ~ 6" MIN.! t UNDISTURBED SOIL 'TYPE "A" ALTERNATE TRENCH WALL SEE NOTE 5 CONCRETE ENCASElAENT 6" MIN.! VARIABLE, DEPENDING UPON PIPE SIZE AND SOIL CONDITIONS I CONCRETE ENCASElAENT 6" lAIN. # 4 BARS LONG. (lYP.) 6" lAIN. TYPE "S" 2 - l' JOINTS (APPLICABLE TO V.C.P. ONLY) VARIES I -J" '1-- -J" I ---r------ ""'\..J- SECTION MIN. DETERlAlNED BY PIPE SIZE BEDDING - SEE SBWD STD. DWG. s-s OR S-B NOTES: 1. CONCRETE ENCASEMENT SHALL BE USED WHEN COVER IS UNDER 4' OR OVER 20'. 2. ENCASElAENT TO BE PLACED AGAINST UNDISTURBED NATURAL GROUND OR FILL COMPACTED TO 90:r: RELATIVE DENSrTY. 3. NO. 4 STEEL REINFORCING BARS SHALL BE USED AS SPECIFIED. 4. TYPE OF CONCRETE ENCASEMENT TO BE USED WILL BE SHOWN ON PLANS OR AS SPECIFIED BY CITY REPRESENTATIVE TO MEET UNFORESEEN FIELD CONDITIONS, UNLESS NOTED OTHERWISE, ENCASEMENT SHALL BE 470-C-2S00 WITH 4" MAX. SLUMP CONCRETE. S. WHERE SLOPED TRENCHES ARE USED, WALLS WILL NOT BEGIN TO SLOPE CLOSER THAN 12" FROlA THE TOP OF THE PIPE. STANDARD PLAN 925 5-10 REVIEWED SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-CONCRETE ENCASEMENT TYPE A, B Ii: C SUPERCEDES REFERENCES DEPUTY CRY ENQINEER RCE S1527 "".ROIIED PUBLIC Q DIRECTOR OF PUBUC WORKS-RCE 57202 DRAWN 1l'I: RC HECKED BY: BZ WORKS NO. REVISIONS DESCRIPTIONS I SHEET 1 OF 1 C:\CITYS1D\SltlS-IO.llWG REV. 08-0'-97 I I I Resolution Number 52.1/ TRENCH WIDTH - -....: -- B ANCHORS V.C.P. SEWER MAIN - SECTION B A-A UNDISTURBED SOIL . z ""- ~ A SAND I BACKFILL I I ) ~r _.J 3" MIN. CLEARANCE BETWEEN REINFORCING STEEL AND EDGE OF CONCRETE SECTION B-B 3" TYPICAL PIPE PIPE X SLOPE SLOPE DISTANCE 100" 1:1 12' 66.6:r: 1-1/2:1 14' (}4 BARS 6" C.C. 50" 2:1 16' 40" 2-1/2:1 18' 3" 33.3" 3:1 20' TYPICAL ~ REINFORCING STEEL PATTERN 1. PIPE ANCHORS REQUIRED ON ALL SLOPES OF 3:1 OR STEEPER. 2. ANCHOR SHALL EXTEND 12" INTO NATURAL UNDISTURBED SOIL 3. CONCRETE SHALL BE S60-C-32S0 W/4" MAX. SLUlAP. 4. ANCHORS FOR TRAPAZOIDAL TRENCH SECTIONS WILL CONFORlA TO TO TRENCH CROSS SECTION AND EXTEND 12" INTO UNDISTURBED SOIL SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-CONCRETE SLOPE ANCHORS STANDARD PLAN 925 5-11 REVIEWED PUBLIC GJ NO. REVISIONS DESCRIPTIONS SUPERCEDES REFERENCES DEPUTY' CIlY ENGINEER-ACE 61527 ""PRlMIl DIRECTOR OF PUBUC WORKS-RCE 57202 DRAWN BY: RC CHECKED BY: BZ WORKS SHEET 1 OF I C:\CITYS1D\STDS-l1.DWG REV. 08-01-97 Resolution Number 51l./I .' V.C.P. MIN. CASING MIN. WALL SIZE SIZE THICKNESS. 6" 16" 1.0. 1/4" S" lB" 1.0. 1/4" 10" 21" 1.0. 5/16" 12" 24" 1.0. 5/16" P.V.C. MIN. CASING MIN. WALL SIZE SIZE THICKNESS. 6" 12" 1.0. 1/4" B" 16" 1.0. 1/4" 10" lS" 1.0. 5/16" 12" 20" 1.0. 5/16" STRAP (1YP.) 3" lAIN. STEEL CASING I CARRIER PIPE JOINT r2" lAIN. FOR EACH LENGTH OF PIPE, 3' LONG 4" X 4" SKIDS BEVELED AT BOTH ENDS, SHALL BE STRAPPED IN PlACE 3" FROI-.4 EACH END OF PIPE. NOTCH SKID TO SEAT STRAP. STRAP SHALL BE 31 B STAINLESS STEEL. ~ I 1. UNUESS NOTED OTHERWISE, CASING SHALL BE INSTALLED BY THE BORE, JACK AND/OR TUNNEL lAETHOD. IF OPEN-CUT INSTALLATION OF CASING IS ALLOWED, BACKFILL SHALL BE IN ACCORDANCE WITH SBSD STD. DWG. S-S OR S-B. 2. SIZE AND THICKNESS OF CASING SHALL BE AS SHOWN IN SCHEDULE. 3. ALL STEEL CASING PIPE FIELD JOINTS SHALL BE WELDED FULL-CIRCUMFERENCE. 4. UNFINISHED 4 "X4" REDWOOD SKIDS SHALL BE PROVIDED PER DETAIL ABOVE. S. CARRIER PIPE SHALL BE AIR PRESSURE TESTED PRIOR TO FILLING CASING. 6. UPSTREAM AND DOWNSTREAM ELEVATIONS OF CARRIER PIPE TO BE VERIFIED PRIOR TO FILLING. 7. EACH END OF CASING SHALL BE SEALED WITH CONCRETE MORTAR. RE.V\EWEl) PUBLIC Q NO. REVISIONS DESCRIPTIONS PIPE STANDARD PLAN 925 5-12 SUPERCEDES REFERENCES I SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-STEEL CASINO DEPUTY CRY ENGtNEER-RCE 61527 ""PRO\IED [)tRt1OlUt( Of PUBLIC WORICS-RCE 57202 DRAW BY' RC HECKED BY' BZ WORKS SHEET 1 or 1 C:\CITYS1D\STDS-I2.DWG REV. 08-01-97 I I I 1/16 BEND MANHOLE W/PVC LINER DRY PACK MECHANICAL PLUG . . .- .. 4 4 . .. Resolution Number :r:2// ,- REVERSE WYE 1/8 BEND 6" MIN. ALL SIDES ALL PIPING TO BE SAIoIE SIZE AS INTERCEPTED SEWER COLD JOINT - , 4 0 4" C.C. ALL SIDES 1/4 BEND S60-C-32S W /4" MAX. SLUlAP CbNCRETE CROWN ELEVATIONS OF lAAIN AND DROP LATERAL TO BE EQUAL SECTION NOTES: 1. DROP MANHOLE TO BE USED FOR SPECIAL SITUATIONS ONLY, AND SHALL NOT BE CONSTRUCTED WITHOUT CITY APPROVAL. 2. ALL NEW OPENINGS CONSTRUCTED INTO MANHOLE SHALL BE DONE BY CORE DRILLING. 3 INTERIOR WALL DF MANHOLE TO BE LINED WITH PVC LINER PER DESIGN STANDARDS FOR SEWER FACILITIES AND STANDARD DRAWING S-14. PUBLIC ~ REVISIONS DESCRIPTIONS STANDARD PLAN SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-DROP MANHOLE DETAIL 925 5-13 REVlE'oml DEPUTY CITY ENGrNEER-RCE 81527 APl'ROIIED NO, DIRECTOR Of PUBUC WORKS-RCE 57202 DRAWN BY: RC HECKED BY: BZ WORKS SUPERCEOES REFERENCES SHEET 1 OF 1 C:\CITYS1D\sroS-13.DWG REV. 08-01-97 Resolution Number ~~I , ~~ . o '" ~ . 0 . ....::t; ~ a.. ~ ~ I{l ~ REMOVE PIPE ABOVE SPRINGUNE BY SAW CUTTING. I '-, , .' :-. 30-1 MIN. 2 - PREFORlAED CORNER TURNBACKS UNDER FRAME I I NON-SKID SURFACE . ON SH , [PREFORMEt '. CORNER . . , WELO STRI ~ YeP B" MIN. 2 _ 2' ~ JOINTS ~:]_ l_--_~]R YeP ---- ---- I .f,' .... . - .... ~ ... nJRNEW:K Of YeP SHAlL BE A MINIMUM or 6". HaLO PVC b~%pCW,9LjISI~ ilI\ftCE APPLY CONTACT CEMENT ADHESIVE TO BOTH SURFACES. SEE SBSD STD, DWGS, S-l, S-2, S-4, S-5, S-13 STANDARD PLAN 925 5-14 REVIEWED SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-PVC LINED MANHOLE FOR SEWERS SUPERCEDES REFERENCES DEPUTY CITY ENGlNEER-RCE, 61527 APPROIIED DIRECTOR OF PUBUC WORKS-RCE 57202 DRAWN BY: RC HECKED BY: BZ PUBLIC Q REVISIONS DESCRIPTIONS I NO, WORKS SHEET 1 Of 1 C:\CrrtSTD\STDS-l REV 08-01-97 . Resolution Number 4':2.1/ . . I ~ J W " '" " :0 0- ~" ~~ ::ll' ....15g, '9"~ (3:Jln 009 r.bw ;o~'" I;; " ~~ " 0" JO w~ ,"", ~ w " " o >: .. !Ii ~ J W W I;; g~ ~;!; -0 w :~ "'''' ~ u~~ >"'- IL~~ 'i::l~ E+ r.;::;i1l1 wz~ ~ol: og,'" J:lx lIJ....g ~ ~Ul..J:t: a:: o.~J.::::E .. iE ~ '" " J W ,. "'", ~~ xw g~ '" ~o ~ I 1 --y^-, I I I I I I I I oJ r ffiz~ I z"':ln~. I ~IL 3!:j w~ .~ 0 I t>l~ ~>i~1D I o.~a::g; I IL:::l:::lCll.&.l I ~~~~ I ______-1 ~ 12 b z :. ~----- o " is !Ii ~ ~ :. ~ Z ~ ; j w i .... u 0 ~ ~ o ~ Z J !i~::::E ~D:g B w... w w ..U") w I ~ o ~ o ~ ~ 4 0- "o~ " " " " w I .. ~ :..t; ::;geg ~w.l;; ~~ ...~ 0' W " ,. iE .~ a:V"> ~ 0 I '" ~~:::E ~ .. ..... ~ffiffi~ tn:::li:Z.... Z:::IfZIa.. " ., '" ~~ i8~ ~ .. , .. .".- I;;;;;~:! oU") w " 4 W. ~ 9 ~1D:! z'" " w "'-"'" .'0 . ::::E~oUJ lX~_ "'" w w w u x a ,- ,. .. ..... I 0- ~ ~ ..... II> w ~ .... . . ~I " 4 4 4 ,. . ~ ,. ,. ~I ..... ~ '" II> 0':" .. )~ '" J :c .... ,. <i'" ::lE ~ 4 .:.~ ,." w 0 ,. 0" 4 "':." . ,,::I ...J ~ " 0", <( w II> 9 . . 00 .... " 4 '" ::; II>Z ,. 1 ::lE zQ . ~ U 00- '" -.. 11>- '. _a: .. >0 1 ...'" J " a:", w z 0 iO!", ~ ""'- :0 .. ~ w ~ J 0 .. ~ wo I;; " 0 J Z 0 iE "0 rR w '" a: " ~ "9 ~~ " " '" 4 '" ;.. 0 " " ,. 9~ " kg, " ugr d ~~ '" '" 9 . . I. ~ 0 w ~ - '" ,. . ~ . ;..u; J B~ II> is _ f D:: '. ~ - u I . J z '" ~ ::> 0 ~ '" -~ .. ;0 ~" "" " w 0 "'''' w . . Z ;::: ~~ ~ :I '. '4.. ~5 ~ '" <( a: . 0 '" '" N ~o '" ,. U .... 'l!" "';: .. 0.0. to ~ W . . . 1" ..... ", '" -'" ~~ 0 N '. . ~ . Z J!!z . ~ J" . of. "''' a: ;; . l:.~':.~ ,,0 "'0 w ~ 0 '" "- -~ ,. w ,. . . O~ . ::l ~ !g::J w , ~ '" " '" . -J ~ r~' "- 1=0 ~il :x: ffi~ . OJ "- ~I ffit;: 0 a 0 ~ " 0: "J W ~- "w w . 8~ 00 'i~ ~O! "'''' ::;> '" " " ,.; ~ 00: 8,. "I;; ... J 0 ~ 00 " ~ z ~" w ~:t II> 0- ~ ~ . , ~ 0 Resolution Number ~JI T-LOCK RIBS OUTSIDE ON THE GAS FLAP. GAS FLAP lA.H. SHELF 1- 4" TYP. ALL AROUND WELD GAS FLAP TO P.V.C. LINER WITH 1" WELD STRIP 4" WELD ALL AROUND POCKET = P.V.C. UNER "" . 1" FLAT STEEL BAR SEALED IN PVC VIEW A-A NOT TO SCALE IV^- I I I I I AI 1 SEE I NOTE I WRAP P.V.C. LINER 1 I AROUND Vr\i'P, AND I I} I ~HR~,~ 'WIT~EEL A~ , I TAKE UP BOLT. L________________ PLACE LOOSE FITTING P .V.C. GAS FLAP ON ALL LATERALS wI T -LOCK STRIPS TOWARD INSIDE lA.H. ' EXIST, PIPE 2" WELD STRIP I .fI.At! NOTE FOR INSTALLATION AT EXISTING M.H., RElAOVE INTERFERING CONCRE1'E AT END OF EACH LATERAL AND EXTEND VCP AS SHOWN. GROUT IN PLACE. EXTEND PVC lA.H. LINER OVER GROUT AND INSTALL GAS FLAP AS SHOWN. SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-P.Y,C. LINER Ii: GAS FLAP INSTALLATION STANDARD PLAN 925 5-16 REVIEWED PUBLIC G) NO, REVISIONS DESCRIPTIONS SUPERCEDES REFERENCES I DEPUTY cny ENGlNEER-ReE .,527 API'ROYEIl DIRECTOR OF PUBUC WORKS-Ref" 57202 DRAWN BY: RC HECKED BY: BZ WORKS SHEET lor, ~",""'1-17 1 I I 10" GRADE RINGS ",. . ,- " ": 6" 0 8" 36" .. . "' ,- " . . ~ " .- ":- : .. . i;', r .,. " .- "'," :. .~ .'.; :.... . .' .. '. .. ..... . "':" .. VAR 60" Resolution Number~11 136"1 , ' ,= .~ ::.~ .~ :: ; .~:: . . . . . : ,...~ '.;" : .. '.~ ';":" . .. .~ :.',; ....;. ',' TYPICAL SECTION FLAT TOP MANHOLE NOTES 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH SBSD STD. DWG. S-l. 2. REINFORCED CONCRETE lAANHOLE, QUIKSET OR APPROVED EQUAL 3. FOR MANOLE FRAME AND COVER, SEE SBSD STD. DWG, S-4, FLA T TOP COVER DEPUTY CITY ENQlNEER-RCE 61527 API'RD\IED ... -.... h ',\ 036" DIA. DIRE~)PN OF qw I I( I " / .... ,- .... ... .fLAM NO. REVISIONS DESCRIPTIONS STANDARD PLAN 925 $-17 SUPERCEDES REfERENCES DIRECTOR OF PUHUC WDRKS-RCE 57202 DRAWN BY: RC CHECKED BY: BZ REVIEWED SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-FLAT TOP MANHOLE PUBLIC Q WORKS SHEET lor, ~_,""I"" Resolution Number ~JI r---~---------------- ----------1------------------------ I , , , , A : I , , , , ! 1 : , , I : INLET. ;:-:/---: :;::;:;b:i~ W ' , , , , , , , ! , , , f-------------------------------L---------------------- I~ L 24-INCH MIN r MANHOLE fRAME AND COVER REMOVED A 1 .1 e..LAM STATIC WATER LINE 1 % L y" L L SECTION A-A CD II'!LET PIPE 4-INCH MINIMUM @ INFLOW TEE AND STANDPIPE G) CROSSOVER TEE AND STANDPIPE o 9AFFLE WALL @ OUTFLOW TEE AND STANDPIPE NOTE: GREASE INTERCEPTOR SHALL BE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE UNIFORM PLUMBING CODE. APPENDIX H_ SEAL BEACH SEWER DEPARTMENT STANDARD DRAWING-TYPICAL GREASE INTERCEPTOR STANDARD PLAN 925 5-18 REVIEWED NO. REVISIONS DESCRIPTIONS SUPERCEOES REFERENCES PUBLIC G) 1 DEPUTY CITY ENGINEER-RCE 61527 APPROVED DIRECTOR OF PUBLIC WORKS-RCE 57202 DRAWN BY: RC CH~CKED BY: BZ WORKS SHEET 1 OF 1 C<\OT1SnI\SlDS-5,DWGllE.YlII-01-17