HomeMy WebLinkAboutPC Packet_04152019CITY OF SEAL BEACH
PLANNING COMMISSION AGENDA
Monday,April 15,2019 —7:00 PM
City Council Chambers
211 Eighth Street
Seal Beach,CA 90740
District 1 —Steve Miller
District 2 —Robert Aguilar –Vice Chair
District 3 —Michael Thomas
District 4 —Patty Campbell –Chair
District 5 —Mariann Klinger
Department of Community Development
Steven Fowler,Assistant Planner
Amy Greyson,Assistant City Attorney
•City Hall office hours are 8:00 a.m.to 5:00 p.m.Monday through Friday.Closed noon
to 1:00 p.m.
•The City of Seal Beach complies with the Americans with Disabilities Act.If you need
assistance to attend this meeting please telephone the City Clerk's Office at least 48 hours
in advance of the meeting at (562)431-2527.
•Planning Commission meetings are broadcast live on Seal Beach TV3 and on the City's
website (www.sealbeachca.gov).Check the SBTV3 schedule for rebroadcast of meeting —
meetings are available on-demand on the website.
•DVDs of Planning Commission meetings may be purchased from Seal Beach TV3 at a cost
of $15 per DVD.Telephone:(562)596 -1404.
•Copies of staff reports and/or written materials on each agenda item are available for public
inspection in City libraries or on the City website
at:http://sealbeachca.suiteonemedia.com/web/home.aspx
PLANNING COMMISSION AGENDA INFORMATION SHEET
The following is a brief explanation of the Planning Commission agenda structure:
AGENDA APPROVAL:The Planning Commission may wish to change the order of the
items on the agenda.
ORAL COMMUNICATIONS:Anyone wishing to address the Planning Commission on
tonight's agenda may do so during this time period.The Planning Commission may also
allow the public to address any other matters within the subject matter jurisdiction of the
Planning Commission.No action can be taken by the Planning Commission on these
communications on this date,unless agendized.
CONSENT CALENDAR:Consent Calendar items are considered routine items that
normally do not require separate consideration.The Planning Commission may make one
motion for approval of all the items listed on the Consent Calendar.
DIRECTOR'S REPORT:Updates and reports from the Director of Community
Development (Planning and Building Divisions)are presented for information to the
Planning Commission and the public.
COMMISSION CONCERNS:Items of concern are presented by the Planning
Commissioners and discussed with staff.
SCHEDULED MATTERS:These items are considered by the Planning Commission
separately and require separate motions.These transactions are considered
administrative and public testimony is not heard.
PUBLIC HEARING ITEMS:Public Hearings allow citizens the opportunity to speak in favor
of or against agendized items.More detailed information is found in the actual agenda
attached.If you have documents to distribute,you should have enough copies for all
Planning Commissioners,City staff,and the public.Please give one to the secretary for
the City files.The documents become part of the public record and will not be returned.
All proceedings are recorded.
CALL TO ORDER
PLEDGE OF ALLEGIANCE
ROLL CALL
APPROVAL OF AGENDA
By Motion of the Planning Commission this is the time to notify the public of any
changes to the agenda,re-arrange the order of the agenda,and provide an
opportunity for any member of the Planning Commission or staff to request an item
be removed from the Consent Calendar for separate action.
ORAL COMMUNICATIONS
At this time members of the public may address the Planning Commission regarding
any items within the subject matter jurisdiction of the Commission.Pursuant to the
Brown Act,the Commission cannot discuss or take action on any items not on the
agenda unless authorized by law.Those members of the public wishing to speak
are asked to come forward to the microphone and state their name for the record.
All speakers will be limited to a period of 5 minutes.
CONSENT CALENDAR
A.Approval of December 17,2018 Minutes
B.Approval of January 22,2019 Minutes
CONTINUED ITEMS
SCHEDULED MATTERS
NEW BUSINESS
C.MINOR USE PERMIT (MUP)19-2
320 Central Avenue
Applicant:Golden Edge Construction on behalf of Linda Tachjian
Request:Request for a Minor Use Permit (MUP 19-2)to allow the installation
of a roof mounted air conditioning unit with screening at a nonconforming
property that is nonconforming due to setbacks and height in the Residential
High Density (RHD-20)zoning area.
Recommendation:After conducting the Public Hearing,staff recommends that
the Planning Commission adopt Resolution No.19-3,APPROVING Minor Use
Permit 19-2 with Conditions.
D.MINOR USE PERMIT (MUP)19-1
339 10th Street
Applicant:Michael Gibbsons
Request:Request for Minor Use Permit (MUP 19-1)to allow an interior
remodel to convert an existing closet into a bathroom at a nonconforming
property that is nonconforming due to setbacks in the Residential High Density
(RHD-20)zoning area.
Recommendation:After conducting the Public Hearing,staff recommends that
the Planning Commission adopt Resolution No.19-2,APPROVING Minor Use
Permit 19-1 with Conditions.
PUBLIC HEARINGS
DIRECTOR'S REPORT
COMMISSION CONCERNS
ADJOURNMENT
Adjourn the Planning Commission to Monday,May 6,2019 at 7:00 p.m.
4
6
3
PLANNING COMMISSION
STAFF REPORT
DATE:April 15, 2019
TO:Planning Commission
THRU:Gloria Harper, City Clerk
FROM:Steve Fowler, Assistant Planner
SUBJECT:Approval of December 17, 2018 Minutes
RECOMMENDATION:Approve the minutes for the Planning Commission meeting
held on December 17, 2018
Prepared by: Approved by:
Gloria Harper Steve Fowler
Gloria Harper Steve Fowler
City Clerk Assistant Planner
Attachment:
1. Minutes
City of Seal Beach – Planning Commission
December 17, 2018
Chair Thomas called the regular meeting of the Planning Commission to order at 7:0 0 p.m.
in the City Council Chambers. Commissioner Klinger led the Pledge of Allegiance.
ROLL CALL
Present: Commissioners: Campbell, Klinger, Thomas, Aguilar
Absent: Grgas
Staff Present: Amy Greyson, Assistant City Attorney
Crystal Landavazo, Interim Community Development Director
Steven Fowler, Assistant Planner
Robin L. Roberts, City Clerk
APPROVAL OF AGENDA
Motion by Campbell, second by Aguilar to approve Agenda.
AYES: Aguilar, Campbell, Klinger, Thomas
NOES: None
ABSENT: Grgas
ABSTAIN: None
Motion Carried
ORAL COMMUNICATIONS
Chair Thomas opened oral communications. Speakers: None. Chair Thomas closed oral
communications.
CONSENT CALENDAR
1. Approval of August 20, 2018 Minutes
2. Approval of November 5, 2018 Minutes
Motion by Campbell, second by Klinger, to approve items on Consent Calendar.
AYES: Aguilar, Campbell, Klinger, Thomas
NOES: None
ABSENT: Grgas
ABSTAIN: None
Motion Carried
SCHEDULED MATTERS
There were no scheduled matters.
CONTINUED ITEMS
There were no continued items.
NEW BUSINESS
3. Minor Use Permit (MUP 18-11)
408 Marina Drive
Applicant: Julie Beck
Request: Request for MINOR USE PERMIT (MUP 18-11) to allow a small
scale commercial recreational use (fitness studio) in a multi-unit commercial
building in the Specialty Commercial (SC) zoning area.
Recommendation: After conducting the Public Hearing, staff recomme nds that the
Planning Commission adopt Resolution No. 18-22, APPROVING Minor Use Permit
18-11 with Conditions.
Assistant Planner Steve Fowler provided a comprehensive staff report on this item.
Commissioner Aguilar inquired about the liquor hours.
Chair Thomas opened the public hearing. Speakers: The applicant Julie Beck spoke
regarding her proposed business. Mike Beckage spoke in support of this item. Chair
Thomas closed public comment.
Campbell moved, second by Aguilar, to adopt Resolution No. 18-22, APPROVING Minor
Use Permit 18-11 with Conditions.
AYES: Aguilar, Campbell, Klinger, Thomas
NOES: None
ABSENT: Grgas
ABSTAIN: None
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
4. Minor Use Permit (MUP 18-12)
122 14th Street
Applicant: Kay MacDonald
Request: Request for a Minor Use Permit (MUP 18-12) to allow the interior
remodel of a nonconforming duplex that is nonconforming due to density,
parking and setbacks in the Residential High Density (RHD-20) zoning area.
Recommendation: After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 18-23, APPROVING Minor Use Permit
18-12 with Conditions.
Assistant Planner Steve Fowler provided a comprehensive staff report and indicated no
correspondence was received regarding the project.
Chair Thomas opened the public hearing. Speakers: None. Chair Thomas closed public
comment.
Aguilar moved, second by Klinger, to adopt Resolution No. 18-23, APPROVING Minor Use
Permit 18-12 with Conditions.
AYES: Aguilar, Campbell, Klinger, Thomas
NOES: None
ABSENT: Grgas
ABSTAIN: None
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
PUBLIC HEARINGS
There were no public hearing items.
DIRECTOR’S REPORT
Interim Director Landavazo provided an ADU Ordinance update and answered
Commissioners questions pertaining to ADU’s.
COMMISSION CONCERNS
Commissioner Campbell encouraged the community to tour the holida y lights in College
Park East and announced that CPENA designated 7 homes as this year’s winners.
Chair Thomas wished everyone a happy holiday and thanked City Clerk Robin Roberts as
this is her last meeting as City Clerk.
ADJOURNMENT
Chair Thomas adjourned the Planning Commission meeting at 7:23 p.m. to Monday,
January 7, 2019 at 7:00 p.m.
___________________________
Dana Engstrom, Deputy City Clerk
Approved: _______________________
Patricia Campbell, Chair
Attest: _______________________
Dana Engstrom, Deputy City Clerk
4
6
4
PLANNING COMMISSION
STAFF REPORT
DATE:April 15, 2019
TO:Planning Commission
THRU:Gloria Harper, City Clerk
FROM:Steve Fowler, Assistant Planner
SUBJECT:Approval of January 22, 2019 Minutes
RECOMMENDATION:Approve the minutes for the Planning Commission meeting
held on January 22, 2019
Prepared by: Approved by:
Gloria Harper Steve Fowler
Gloria Harper Steve Fowler
City Clerk Assistant Planner
Attachment:
1. Minutes
City of Seal Beach – Planning Commission
January 22, 2019
Chair Thomas called the regular meeting of the Planning Commission to order at 7:0 1 p.m.
in the City Council Chambers. Commissioner Campbell led the Pledge of Allegiance.
ROLL CALL
Present: Commissioners: Campbell, Grgas, Thomas, Aguilar
Absent: Klinger
Staff Present: Carol Lynch, Assistant City Attorney
Crystal Landavazo, Interim Community Development Director
Steven Fowler, Assistant Planner
Dana Engstrom, Deputy City Clerk
Motion by Thomas, second by Aguilar to excuse Commissioner Klinger’s absence.
AYES: Aguilar, Campbell, Grgas, Thomas
NOES: None
ABSENT: Klinger
ABSTAIN: None
Motion Carried
APPROVAL OF AGENDA
Motion by Campbell, second by Aguilar, to approve Agenda.
AYES: Aguilar, Campbell, Grgas, Thomas
NOES: None
ABSENT: Klinger
ABSTAIN: None
Motion Carried
ORAL COMMUNICATIONS
Chair Thomas opened oral communications. Speakers: Lynn Larson spoke regarding item
B. Chair Thomas closed oral communications.
CONSENT CALENDAR
There were no consent calendar items.
SCHEDULED MATTERS
A. Reorganization of the Planning Commission – Election of new
Chairperson and Vice-Chairperson for 2019
Motion by Aguilar to nominate Commissioner Campbell for Chair, second by Grgas.
AYES: Aguilar, Campbell, Grgas, Thomas
NOES: None
ABSENT: Klinger
ABSTAIN: None
Motion Carried
Motion by Campbell to nominate Commissioner Aguilar for Vice Chair, second by Grgas.
AYES: Aguilar, Campbell, Grgas, Thomas
NOES: None
ABSENT: Klinger
ABSTAIN: None
Motion Carried
CONTINUED ITEMS
There were no continued items.
NEW BUSINESS
B. Minor Use Permit (MUP) 18-13
48 Riversea Road
Applicant: Baxter & June Arnold
Request: Request for a Minor Use Permit (MUP 18-13) to allow a two-story
manufactured home within Seal Beach Shores located in the Residential High
Density (RHD-33) zoning area.
Recommendation:
After conducting the Public Hearing, staff recommends that the Planning
Commission adopt Resolution No. 19-1, APPROVING Minor Use Permit 18-13
with Conditions.
Assistant Planner Steve Fowler provided a comprehensive staff report and indicated no
correspondence was received regarding the project.
There was general discussion regarding the history of the trailer park, classifications, and
requirements.
Chair Campbell opened the public hearing. Speakers: The applicant’s realtor, Serena
Goss spoke regarding requirements of the trailer park. Chair Campbell closed public
comment.
Aguilar moved, second by Thomas, to adopt Resolution No. 19-1, APPROVING Minor Use
Permit 18-13 with Conditions.
AYES: Aguilar, Campbell, Grgas, Thomas
NOES: None
ABSENT: Klinger
ABSTAIN: None
Motion Carried
Assistant City Carol Lynch noted that the ten-day appeal period starts tomorrow.
DIRECTOR’S REPORT
Interim Director Landavazo had no comments.
COMMISSION CONCERNS
Commissioner Grgas inquired about applications for garage conversions. Interim Director
Landavazo provided an update on the ADU Ordinance at the request of Commissioner
Grgas.
Commissioner Aguilar expressed his excitement regarding the Pier and Bay Theater
completion in 2019.
ADJOURNMENT
Chair Campbell adjourned the Planning Commission meeting at 7:32 p.m. to Monday,
February 4, 2019 at 7:00 p.m.
___________________________
Dana Engstrom, Deputy City Clerk
Approved: _______________________
Patricia Campbell, Chair
Attest: _______________________
Dana Engstrom, Deputy City Clerk
PLANNING COMMISSION
STAFF REPORT
DATE:April 15, 2019
TO:Planning Commission
FROM:Steve Fowler, Assistant Planner
SUBJECT:Request for MINOR USE PERMIT (MUP 19-2) to allow the installation
of a roof mounted air conditioning unit with screening at a
nonconforming property that is nonconforming due to setbacks and
height in the Residential High Density (RHD-20) zoning area.
LOCATION:320 Central Avenue
APPLICANT:Golden Edge Construction on behalf of Linda Tachjian
RECOMMENDATION:After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 19-3, APPROVING Minor
Use Permit 19-2 with Conditions.
GENERAL PLAN
DESIGNATION:
RESIDENTIAL HIGH DENSITY
ZONE:RHD-20 (RESIDENTIAL HIGH DENSITY)
SITE DESCRIPTION:ASSESSOR’S PARCEL NUMBER: 043-113-31
LOT AREA: 2,565.5 sf.ft.
GROSS FLOOR AREA: 2,417 sq. ft.
SURROUNDING PROPERTIES:
NORTH: RESIDENTIAL HIGH DENSITY (RHD-20)
SOUTH: RESIDENTIAL HIGH DENSITY (RHD-20)
EAST: RESIDENTIAL HIGH DENSITY (RHD-20)
WEST: RESIDENTIAL HIGH DENSITY (RHD-20)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of a roof mounted air conditioning unit at an
existing nonconforming residence where only minor modifications are required for the
renovation.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on April 4,
2019 and mailed to property owners and occupants within a 300’ radius of the subject property
on April 4, 2019, with affidavits of publishing and mailing on file.
.
VICINITY MAP: AERIAL MAP:
ANALYSIS
The subject site is located on the southwest corner of Central Avenue and 4th Street, in the
Residential High Density (RHD-20) zone. The property is developed with a two-story single-
family residence with attached garage totaling approximately 2,417 square feet in size. The
application is to allow the installation of a roof mounted air conditioning unit with screening. The
site is surrounded by single-family residences on all sizes.
The subject property is nonconforming due to interior side yard setback and height. According to
Table 11.2.05.015 of the Seal Beach Municipal Code, interior lot properties in the RHD-20 zone
are required to maintain a side yard setback that is 10% of the lot width, or a 3 ft. minimum. The
subject property measures approximately 25.65 feet wide by 100 feet deep. Based on these
dimensions, the development standard requires a side yard setback of 3 feet. The residence
has a one-foot 6 inch side yard setback at the attached garage in the rear of the property.
According to Table 11.2.05.015 of the Seal Beach Municipal Code, properties in the RHD-20
zone are required to not exceed a maximum height of 25 feet. The existing residence is 26 feet
in height.
The owner is requesting approval of Minor Use Permit (MUP) 19-2 to allow the installation of a
roof mounted air conditioning unit with screening on a nonconforming property that is
nonconforming due to setbacks and height. This will add a roof mounted air conditioning unit
with screening to an existing two-story residence. The proposed installation will not result in
additional lot coverage as the areas of construction are already covered by existing structures.
The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor improvements which
involve the removal or alteration of a structure’s exterior or other similar improvements, as
determined by the director. The subject building is proposed to have no additional bedrooms or
bathrooms. The alterations proposed on the subject site are consistent with the provisions of
this code and similar to other improvements in the area. The proposal will not intensify the
nonconforming setback or height requirement as the screening is under the 25 feet height limit
and will maintain a minimum 3 feet interior setback. The resolution conditions the approval to
maintain continuing compliance with those requirements.
CONCLUSION
After concluding the public hearing and receiving public testimony, staff recommends that the
Planning Commission adopt attached Resolution No. 19-3 approving MUP 19-2 to allow the
installation of a roof mounted air conditioning unit with screening at a nonconforming property.
Prepared by:
Steve Fowler
Steve Fowler
Community Development Department
Attachments:
1. Resolution No. 19-3 – A Resolution of the Planning Commission of the City of Seal
Beach Approving Minor Use Permit 19-2 to allow the installation of a roof mounted air
conditioning unit with screening at a nonconforming property at 320 Central Avenue in
the Residential High Density (RHD-20) zoning area.
2. Site Plan and Elevations
Page 1 of 3
RESOLUTION NO. 19-3
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
SEAL BEACH APPROVING MINOR USE PERMIT 19-2 TO ALLOW
THE INSTALLATION OF A ROOF MOUNTED AIR CONDITIONING
UNIT WITH SCREENING AT A NONCONFORMING PROPERTY THAT
IS NONCONFORMING DUE TO SETBACKS AND HEIGHT IN THE
RESIDENTIAL HIGH DENSITY (RHD-20) ZONED AREA AT 320
CENTRAL AVENUE.
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES HEREBY RESOLVE:
Section 1. Golden Edge Construction (“the applicant”) on behalf of Linda Tachjian
(“the owner”) submitted an application to the Community Development Department for Minor Use
Permit 19-2. The proposed project includes the proposed installation of a roof mounted air
conditioning unit with screening at a nonconforming property that is nonco nforming due to setbacks
and height located in the Residential High Density (RHD-20) zoning area.
Section 2. This project is determined to be a Class 1 (Existing Facility) Categorical
Exemption pursuant to Section 15301 of the Guidelines for the California Environmental Quality Act
(Public Resources Code Section 21000 et seq.) for the permitting of a roof mounted air conditioning
unit at an existing nonconforming residence where only minor modifications are required for the
renovation.
Section 3. A duly noticed public meeting was held before the Planning Commission
on April 15, 2019 to consider Minor Use Permit 19-2. At the public meeting, the Planning Commission
received into the record all evidence and testimony provided on this matter. The record of the hearing
indicates the following:
A. The applicant submitted an application to the Community Development
Department for Minor Use Permit 19-2 for a proposed project at 320 Central Avenue, Seal Beach,
California.
B. The subject property is rectangular in shape with a lot area of approximately
2.565.5 square feet. The subject property has a lot width of 25.65 feet with a lot depth of 100 feet.
The site is surrounded by residential uses on all sides.
C. The subject property is currently developed with a two-story single family
residence with an attached two-car garage. Based on the setback on the west side and the height of
the existing residence, the subject property is considered nonconforming. The proposed
improvements will not expand any existing nonconf ormity because the proposed roof mounted air
conditioning unit with screening will not exceed 25 feet in height and will maintain the required 3 feet
setback which meets all setback and height requirements.
D. The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor
improvements which involve the removal or alteration of a structure’s exterior or other similar
improvements, as determined by the director through the approval of a Minor Use Permit. The
applicant is requesting to install a roof mounted air conditioning unit with screening.
Section 4. Based upon the facts contained in the record, including those stated in
the preceding Section of this resolution and pursuant to Chapter 11.5.20 of the Seal Beach Municipal
Code, the Planning Commission makes the following findings:
A. The proposed minor improvements are consistent with the General Plan which
encourages architectural diversity in the Old Town area (Planning Area 1) while ensuring compatibility
between residential and commercial uses. The General Plan also recognizes existing nonconforming
land uses and permits minor alterations. The proposed installation of a roof mounted air conditioning
unit with screening of the existing residence will not change the character of the property, will not
expand any nonconformity, and will be consistent with other surrounding properties.
Resolution 19-3
320 Central avenue
Page 2 of 3
B. The proposed use is allowed within the applicable zoning district with Minor Use
Permit approval and will comply with all other applicable provisions of the Municipal Code. The
subject site is located within the Old Town RHD-20 zone, an area where the Seal Beach Municipal
Code (Section 11.4.40.015.B) allows minor improvement which involves the removal or alteration of a
structure’s exterior or other similar improvements, as determined by the director m with approval of a
Minor Use Permit.
C. The proposed use, as conditioned below, will be located on a site that is
physically adequate for the type, density, and intensity of use being proposed, including provision of
services, and the absence of physical constraints. The subject site is currently developed with a two-
story single-family residence and is considered nonconforming due to setbacks and height. The
installation of a roof mounted air conditioning unit with screening will not add habitable space and will
maintain development standards applicable to the RHD-20 zone. The improvement will not increase
density or change beyond existing use of the property.
D. The location, size, design, and operating characteristics of the proposed use,
as conditioned below, will be compatible with and will not adversely affect uses and properties in the
surrounding neighborhood. The subject site is located within the RHD-20 zone, which consists of
properties developed as single family and multi-family residences. The improvement will not add
habitable space, will not change existing operating characteristics of the single -family residence, and
will remain similar to surrounding uses throughout RHD-20.
E. The establishment, maintenance, and operation of the proposed use will not be
detrimental to the health, safety, or welfare of persons residing or working in the vicinity. The
installation of a roof mounted air conditioning unit with screening will not increase bedrooms, exceed
the bedroom/bathroom ratio authorized under the development standards, or intensify use on the
property. The subject site will continue to operate as a residential property, which is consistent with
the uses in the surrounding neighborhood.
Section 5. Based on the foregoing, the Planning Commission hereby approves
Minor Use Permit 19-2 for the installation of a roof mounted air conditioning unit with screening on an
existing single-family residence that is nonconforming due to setbacks and height is subject to the
following conditions:
1. Minor Use Permit 19-2 is approved for the installation of a roof mounted air conditioning unit
with screening of the existing single-family residence on the nonconforming property located at
320 Central Avenue.
2. All plan check and future construction shall be in substantial compliance with the plans
approved through Minor Use Permit 19-2. All new construction shall comply with all applicable
state and local codes.
3. The applicant is required to obtain all Building and Safety permits prior to construction or
demolition.
4. The applicant is required to obtain California Coastal Commission approval prior to submission
of plans for plan check.
5. All materials, color, and finishes of the wall finish will be consistent with existing roof pitches
and exterior finishes of the residential dwelling.
6. The height of the roof mounted air conditioning unit with screening shall not exceed the 25-foot
height limit applicable to the property, and the property including the air conditioning unit shall
maintain the minimum three-foot interior side yard setback at all times.
7. This Minor Use Permit shall not become effective for any purpose unless an “Acceptance of
Conditions” form has been signed, notarized, and returned to the Community Development
Department; and until the ten (10) day appeal period has elapsed.
Resolution 19-3
320 Central avenue
Page 3 of 3
8. The applicant shall indemnify, defend and hold harmless the City, its officers, agents and
employees (collectively “the City” hereinafter) from any and all claims and losses whatsoever
occurring or resulting to any and all persons, firms, or corporations furnishing or supplying
work, services, materials, or supplies in connection with the performance of the use permitted
hereby or the exercise of the rights granted herein, and any and all claims, lawsuits or actions
arising from the granting of or the exercise of the rights permitted by this Minor Use Permit,
and from any and all claims and losses occurring or resulting to any person, firm, corporation
or property for damage, injury or death arising out of or connected with the performance of the
use permitted hereby. Applicant’s obligation to indemnify, defend and hold harmless the City
as stated herein shall include, but not be limited to, paying all fees and costs incurred by legal
counsel of the City’s choice in representing the City in connection with any such claims,
losses, lawsuits or actions, expert witness fees, and any award of damages, judgments,
verdicts, court costs or attorneys’ fees in any such lawsuit or action.
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning Commission at a
meeting thereof held on April 15, 2019, by the following vote:
AYES: Commissioners
NOES: Commissioners
ABSENT: Commissioners
ABSTAIN: Commissioners
Patty Campbell
Chairperson
ATTEST:
__________________________
Steve Fowler
Planning Commission Secretary
PLANNING COMMISSION
STAFF REPORT
DATE:April 15, 2019
TO:Planning Commission
FROM:Steve Fowler, Assistant Planner
SUBJECT:Request for MINOR USE PERMIT (MUP 19-1) to allow an interior
remodel to convert an existing closet into a bathroom at a
nonconforming property that is nonconforming due to setbacks in the
Residential High Density (RHD-20) zoning area.
LOCATION:339 10th Street
APPLICANT:Michael Gibbsons
RECOMMENDATION:After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 19-2, APPROVING Minor
Use Permit 19-1 with Conditions.
GENERAL PLAN
DESIGNATION:
RESIDENTIAL HIGH DENSITY
ZONE:RHD-20 (RESIDENTIAL HIGH DENSITY)
SITE DESCRIPTION:ASSESSOR’S PARCEL NUMBER: 043-113-31
LOT AREA: 2,937.5 sf.ft.
GROSS FLOOR AREA: 1,301.71 sq. ft.
SURROUNDING PROPERTIES:
NORTH: RESIDENTIAL HIGH DENSITY (RHD-20)
SOUTH: RESIDENTIAL HIGH DENSITY (RHD-20)
EAST: RESIDENTIAL HIGH DENSITY (RHD-20)
WEST: MAIN STREET SPECIFIC PLAN (MSSP)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of an interior remodel at an existing
nonconforming residence where only minor modifications are required for the renovation.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on April 4,
2019 and mailed to property owners and occupants within a 300’ radius of the subject property
on April 4, 2019, with affidavits of publishing and mailing on file.
.
VICINITY MAP: AERIAL MAP:
ANALYSIS
The subject site is located on the west side of 10th Street between Pacific Coast Highway and
Electric Avenue at 339 10th Street, in the Residential High Density (RHD-20) zone. The property
is developed with a one-story single-family residence with a garage totaling approximately 1,301
square feet in size. The application is for the remodel of the interior of the interior of the
residence to add a bathroom the site is surrounded by single-family residences to the north and
south, to the east is a church, and to the west are commercial uses.
The subject property is nonconforming due to the south interior side yard setback of the
detached garage. According to Table 11.2.05.015 of the Seal Beach Municipal Code, interior lot
properties in the RHD-20 zone are required to maintain a side yard setback that is 10% of the
lot width, or a 3 ft. minimum. The subject property measures approximately 25 feet wide by
117.5 feet deep. Based on these dimensions, the development standard requires a side yard
setback of 3 feet. The residence has 3 ft. side yard setback but the detached garage is
constructed on the south property line.
The owner is requesting approval of Minor Use Permit (MUP) 19-1 to allow an interior remodel
to convert an existing closet into a bathroom at a nonconforming property that is nonconforming
due to setbacks. This will add a bathroom to the existing two bedrooms, one bathroom
residence. The proposed remodel will not result in additional lot coverage as the areas of
construction are already covered by existing structures.
The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor improvements which
involve the removal or alteration to less than 25% of a structure’s interior walls, provided the
bedroom/bathroom ratio does not exceed one and one half bathrooms for each bedroom. The
subject building is proposed to have no additional bedrooms and add a bathroom which will
have a bedroom to bathroom ratio of a bathroom for each bedroom which will conform to this
provision. The alterations proposed on the subject site are consistent with the provisions of this
code.
CONCLUSION
After concluding the public hearing and receiving public testimony, staff recommends that the
Planning Commission adopt attached Resolution No. 19-2 approving MUP 19-1 to allow an
interior remodel to convert an existing closet into a bathroom at a nonconforming property.
Prepared by:
Steve Fowler
Steve Fowler
Community Development Department
Attachments:
1. Resolution No. 19-2 – A Resolution of the Planning Commission of the City of Seal
Beach Approving Minor Use Permit 19-1 to allow an interior remodel to convert an
existing closet into a bathroom at a nonconforming property at 339 10th Street in the
Residential High Density (RHD-20) zoning area.
2. Site Plan and Floor Plan
Page 1 of 3
RESOLUTION NO. 19-2
A RESOLUTION OF THE PLANNING COMMISSION OF THE
CITY OF SEAL BEACH APPROVING MINOR USE PERMIT 19-1
TO ALLOW AN INTERIOR REMODEL TO CONVERT AN
EXISTING CLOSET INTO A BATHROOM AT A
NONCONFORMING PROPERTY THAT IS NONCONFORMING
DUE TO SETBACKS IN THE RESIDENTIAL HIGH DENSITY
(RHD-20) ZONED AREA AT 339 10TH STREET.
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES HEREBY
RESOLVE:
Section 1. Michael Gibbsons (“the applicant”) submitted an application to the
Community Development Department for Minor Use Permit 19-1. The proposed project
includes the interior remodel to convert an existing closet into a bathroom at a nonconforming
property that is nonconforming due to setbacks located in the Residential High Density (RHD-
20) zoning area.
Section 2. This project is determined to be a Class 1 (Existing Facility)
Categorical Exemption pursuant to Section 15301 of the Guidelines for the California
Environmental Quality Act (Public Resources Code Section 21000 et seq.) for the permitting
of an interior remodel at an existing nonconforming residence where only minor modifications
are required for the renovation.
Section 3. A duly noticed public meeting was held before the Planning
Commission on April 15, 2019 to consider Minor Use Permit 19-1. At the public meeting, the
Planning Commission received into the record all evidence and testimony provided on this
matter. The record of the hearing indicates the following:
A. The applicant submitted an application to the Community Development
Department for Minor Use Permit 19-1 for a proposed project at 339 10th Street, Seal Beach,
California.
B. The subject property is rectangular in shape with a lot area of
approximately 2,937 square feet. The subject property has a lot width of 25 feet with a lot
depth of 117.5 feet. The site is surrounded by residential uses on the north and south,
commercial uses to the west and a church to the east.
C. The subject property is currently developed with a one -story single
family residence with a detached two -car garage. Based on the setback on the south side
the subject property is considered nonconforming. The proposed improvements will not
expand any existing nonconformity because the proposed remodel will take place in the
residence which meets all setback requirements.
D. The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor
improvements which involve the interior remodel of less than 25 percent of the walls through
the approval of a Minor Use Permit. The applicant is requesting to remodel the interior of the
residence to convert an existing closet into a bathroom.
Section 4. Based upon the facts contained in the record, including those
stated in the preceding Section of this resolution and pursuant to Chapter 11.5.20 of the Seal
Beach Municipal Code, the Planning Commission makes the following findings:
Resolution 19-2
339 10th Street
Page 2 of 3
A. The proposed minor improvements are consistent with the General Plan
which encourages architectural diversity in the Old Town area (Planning Area 1) while
ensuring compatibility between residential and commercial uses. The General Plan also
recognizes existing nonconforming land uses and permits minor alterations. The proposed
remodel to convert an existing closet into a bathroom of the existing residence will not
change the character of the property, will not expand any nonconformity, and will be
consistent with other surrounding properties.
B. The proposed use is allowed within the applicable zoning district with
Minor Use Permit approval and will comply with all other applicable provisions of the
Municipal Code. The subject site is located within the Old Town RHD-20 zone, an area where
the Seal Beach Municipal Code (Section 11.4.40.015.B) allows minor improvement which
involves a remodel to convert an existing closet into a bathroom with approval of a Minor Use
Permit.
C. The proposed use, as conditioned below, will be located on a site that is
physically adequate for the type, density, and intensity of use being proposed, including
provision of services, and the absence of physical constraints. The subject site is currently
developed with a one-story single-family residence and is considered nonconforming due to
setbacks. The remodel to convert an existing closet into a bathroom will not add habitable
space and will maintain development standards applicable to the RHD-20 zone. The
improvement will not increase density or change beyond existing use of the property.
D. The location, size, design, and operating characteristics of the proposed
use, as conditioned below, will be compatible with and will not adversely affect uses and
properties in the surrounding neighborhood. The subject site is located within the RHD-20
zone, which consists of properties developed as single family and multi -family residences.
The improvement will not add habitable space, will not change existing operating
characteristics of the single-family residence, and will remain similar to surrounding uses
throughout RHD-20.
E. The establishment, maintenance, and operation of the proposed use will
not be detrimental to the health, safety, or welfare of persons residing or working in the
vicinity. The remodel to convert an existing closet into a bathroom will not increase
bedrooms, exceed the bedroom/bathroom ratio authorized under the development standards,
or intensify use on the property. The subject site will continue to operate as a residential
property, which is consistent with the uses in the surrounding neighborhood.
Section 5. Based on the foregoing, the Planning Commission hereby
approves Minor Use Permit 19-1for the remodel to convert an existing closet into a bathroom
within an existing single-family residence that is nonconforming due to setbacks is subject to
the following conditions:
1. Minor Use Permit 19-1 is approved for the remodel to convert an existing closet into a
bathroom of the existing single-family residence on the nonconforming property
located at 339 10th Street.
2. All plan check and future construction shall be in substantial compliance with the plans
approved through Minor Use Permit 19-1. All new construction shall comply with all
applicable state and local codes.
Resolution 19-2
339 10th Street
Page 3 of 3
3. The applicant is required to obtain all Building and Safety permits prior to construction
or demolition.
4. All materials, color, and finishes of the wall finish will be consistent with existing roof
pitches and exterior finishes of the residential dwelling.
6. This Minor Use Permit shall not become effective for any purpose unless an
“Acceptance of Conditions” form has been signed, notarized, and returned to the
Community Development Department; and until the ten (10) day appeal period has
elapsed.
7. The applicant shall indemnify, defend and hold harmless the City, its officers, agents
and employees (collectively “the City” hereinafter) from any and all claims and losses
whatsoever occurring or resulting to any and all persons, firms, or corporations
furnishing or supplying work, services, materials, or supplies in connection with the
performance of the use permitted hereby or the exercise of the rights granted herein,
and any and all claims, lawsuits or actions arising from the granting of or the exercise
of the rights permitted by this Minor Use Permit, and from any and all claims and
losses occurring or resulting to any person, firm, corporation or property for damage,
injury or death arising out of or connected with the performance of the use permitted
hereby. Applicant’s obligation to indemnify, defend and hold harmless the City as
stated herein shall include, but not be limited to, paying all fees and costs incurred by
legal counsel of the City’s choice in representing the City in connection with any such
claims, losses, lawsuits or actions, expert witness fees, and any award of damages,
judgments, verdicts, court costs or attorneys’ fees in any such lawsuit or action .
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning Commission at
a meeting thereof held on April 15, 2019, by the following vote:
AYES: Commissioners
NOES: Commissioners
ABSENT: Commissioners
ABSTAIN: Commissioners
Patty Campbell
Chairperson
ATTEST:
__________________________
Steve Fowler
Planning Commission Secretary
NEW WALL
WALL LEGEND
EXISTING WALL
DEMO WALL
3' - 1"R 1' - 3"(E) BEDROOM 1
(E) BEDROOM 2 (E) BATHROOM
(E) CLOSET
(E) LIVING ROOM
(N) RESTROOM
(E) KITCHEN
(E) DINING ROOM
(E) HALLWAY
(E) GARAGE (N) WATER
HEATER LOCATION
(N) ELEC. PANEL
LOCATION
(E) DECK
3' - 6" 3' - 10"
3' - 0" 2' - 3"
3' - 6" 3' - 7"
7' - 1"5' - 4"(N) ELEC.
BREAKER
LOCATION
PROPERTY LINE
PROPERTY LINEPROPERTY LINEPROPERTY LINENORTH
117' - 6"25' - 0"1. THIS PROJECT CONFORM TO 2017 CBC, 2013 CPC, 2013 CMC, 2013 CEC, 2013 ENERGY CODE.
2. ALL CONCENTRATED DRAINAGE, INCLUDING ROOF WATER, SHALL BE CONDUCTED VIA GRAVITY, TO
THE STREET OR AN APPOVED LOACTION AT A 2% MINIMUM
3. MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN COMPLIANCE WITH
THE APPROPRIATE INFILTRATION STANDARDS. CAULK PLUMBING AND ELECTRICAL
PENETRATIONS,ALL WINDOW AND DOOR FRAMES, BETWEEN WALL SOLEPLATES AND FLOORS AND
ALL OTHER OPENING IN THE ENVELOPE. ALL EXTERIOR OPENINGS SHALL BE PROPERLY
WEATEHRSTRIPPED, CERTIFIED AND LABELED
4. THE BUILDING DESIGN MEETS THE REQUIREMENTS OF TITLE 24, PART 2, CHAPTER 2-53. INSULATION
INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY
THE INSTALLER AND BUILDER STATING THAT THE INSTALLATION CONFORMS WITH THE
REQUIREMENTS OF TITLE 24, CHAPTER. 2-53 AND THAT THE MATERIALS INSTALLED CONFORM WITH
THE REQUIREMENTS OF TITLE 20, CHAPTER2, SUBCHAPTER4, ARTICLE 3
5. MINIMUM DUAL GLAZING REQUIRED IN ALL NEW WINDOWS
6. CONCEALED SPACES OF WALLS, PARTITIONS AND FU- RRING SHALL BE FIRE STOPPED WITH 2 IN.
MATERIAL. THE FULL WIDTH OF THE STUDS AT THE FLOOR AND CEILING LEVELS, AND AT
INTERVALS NOT TO EXCEED 10 FEET HORIZONTALLY.
7. ALL INFORMATION SHOWN IN THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE
BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY, WHERE ACTUAL CONDITIONS
CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE DESIGNER SO THAT THE PROPER
REVISIONS MAY BE MADE, MODIFICATIONS OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE
WITHOUT WRITTEN APPROVAL OF THE DESIGNER OR ENGINEER.
SCOPE OF WORK:
RELOCATION OF ELECTRIC METER, WATER
HEATER AND CONSTRUCTION OF NEW RESTROOM
WHITTIN EXISTING CONSTRUCTION, NO SQUARE
FOOTAGE ADDED.
ZONING RHD-PD
SITE AREA 2,937.5 SF
EXISTING RESIDENCE 899 SF
EXISTING GARAGE 402.71 SF
TOTAL LIVABLE AREA 899 SF
LOT COVERAGE 44.31 %
CODE 2017 CRC
LEGAL DESCRIPTION:
PARCEL # 043-113-31
SHEET NUMBERSHEET TITLEDESIGNER PROJECT NO.:
DRAWN BY:
CHECKED BY:
SCALE:
ISSUE
54321□□□□□
54321□□□□□
□
D
□
C
□
B
□
A PROJECT NAMEOF 339 10th STREETSEAL BEACH, CA 90740DESIGNER:Juan Guzman 626.388.7389Author
Checker
T-01FLOOR PLANRESIDENTIAL REMODELSCALE:1/4" = 1'-0"
GROUND LEVEL 1
SCALE:1/4" = 1'-0"
PROJECT INFORMATION 2 SCALE:1/4" = 1'-0"
VICINITY MAP