HomeMy WebLinkAboutPacket_08052019CITY OF SEAL BEACH
PLANNING COMMISSION AGENDA
Monday,August 5,2019 —7:00 PM
City Council Chambers
211 Eighth Street
Seal Beach,CA 90740
District 1 —Steve Miller
District 2 —Robert Aguilar –Vice Chair
District 3 —Michael Thomas
District 4 —Patty Campbell –Chair
District 5 —Mariann Klinger
Department of Community Development
Steven Fowler,Interim Community Development Director
Marco Cuevas,Assistant Planner
Amy Greyson,Assistant City Attorney
•City Hall office hours are 8:00 a.m.to 5:00 p.m.Monday through Friday.Closed noon
to 1:00 p.m.
•The City of Seal Beach complies with the Americans with Disabilities Act.If you need
assistance to attend this meeting please telephone the City Clerk's Office at least 48 hours
in advance of the meeting at (562)431-2527.
•Planning Commission meetings are broadcast live on Seal Beach TV3 and on the City's
website (www.sealbeachca.gov).Check the SBTV3 schedule for rebroadcast of meeting —
meetings are available on-demand on the website.
•DVDs of Planning Commission meetings may be purchased from Seal Beach TV3 at a cost
of $15 per DVD.Telephone:(562)596 -1404.
•Copies of staff reports and/or written materials on each agenda item are available for public
inspection in City libraries or on the City website
at:http://sealbeachca.suiteonemedia.com/web/home.aspx
PLANNING COMMISSION AGENDA INFORMATION SHEET
The following is a brief explanation of the Planning Commission agenda structure:
AGENDA APPROVAL:The Planning Commission may wish to change the order of the
items on the agenda.
ORAL COMMUNICATIONS:Anyone wishing to address the Planning Commission on
tonight's agenda may do so during this time period.The Planning Commission may also
allow the public to address any other matters within the subject matter jurisdiction of the
Planning Commission.No action can be taken by the Planning Commission on these
communications on this date,unless agendized.
CONSENT CALENDAR:Consent Calendar items are considered routine items that
normally do not require separate consideration.The Planning Commission may make one
motion for approval of all the items listed on the Consent Calendar.
DIRECTOR'S REPORT:Updates and reports from the Director of Community
Development (Planning and Building Divisions)are presented for information to the
Planning Commission and the public.
COMMISSION CONCERNS:Items of concern are presented by the Planning
Commissioners and discussed with staff.
SCHEDULED MATTERS:These items are considered by the Planning Commission
separately and require separate motions.These transactions are considered
administrative and public testimony is not heard.
PUBLIC HEARING ITEMS:Public Hearings allow citizens the opportunity to speak in favor
of or against agendized items.More detailed information is found in the actual agenda
attached.If you have documents to distribute,you should have enough copies for all
Planning Commissioners,City staff,and the public.Please give one to the secretary for
the City files.The documents become part of the public record and will not be returned.
All proceedings are recorded.
CALL TO ORDER
PLEDGE OF ALLEGIANCE
ROLL CALL
APPROVAL OF AGENDA
By Motion of the Planning Commission this is the time to notify the public of any changes
to the agenda,re-arrange the order of the agenda,and provide an opportunity for any
member of the Planning Commission or staff to request an item be removed from the
Consent Calendar for separate action.
ORAL COMMUNICATIONS
At this time members of the public may address the Planning Commission regarding any
items within the subject matter jurisdiction of the Commission.Pursuant to the Brown Act,
the Commission cannot discuss or take action on any items not on the agenda unless
authorized by law.Those members of the public wishing to speak are asked to come
forward to the microphone and state their name for the record.All speakers will be limited
to a period of 5 minutes.
CONSENT CALENDAR
A.Approval of the July 1,2019 Minutes
B.Approval of the July 15,2019 Minutes
CONTINUED ITEMS
SCHEDULED MATTERS
NEW BUSINESS
C.Minor Use Permit (MUP 19-5)
228 13th Street
Applicant:Otis Architecture
Request:Request for a Minor Use Permit (MUP 19-5)to allow the interior remodel
and exterior remodel of an existing two-story single-family residence that is
nonconforming due to setbacks and interior garage size within the Residential High
Density (RHD-20)zoning area.
Recommendation:After reviewing the application,staff recommends that the
Planning Commission adopt Resolution 19-12,APPROVING Minor Use Permit 19-5
with conditions.
D.MINOR USE PERMIT (MUP 19-4)
43 B Surfside Avenue
Applicant:FARR Capital LLC/Kevin Chinnock
Request:Request for a MINOR USE PERMIT (MUP 19-4)to allow an interior and
exterior remodel to convert an existing first floor family room and kitchen to a master
bedroom,and convert the existing second floor master bedroom and bathroom area
into a kitchen,living and dining room at a nonconforming property that is
nonconforming due to setbacks in the Residential Low Density (RLD-9)Zone.
Recommendation:After conducting the Public Hearing,staff recommends that the
Planning Commission adopt Resolution No.19-11,APPROVING Minor Use Permit
19-4 with Conditions
PUBLIC HEARINGS
E.Conditional Use Permit (CUP 19-6)
218 13th Street
Applicant:Steve Sennikoff
Request:Request for a Conditional Use Permit (CUP 19-6)to allow the addition of
751 square feet and the interior remodel of an existing one-story single-family
residence that is nonconforming due to setbacks within the Residential High Density
(RHD-20)zoning area.
Recommendation:After reviewing the application,staff recommends that the
Planning Commission adopt Resolution 19-14,APPROVING Conditional Use Permit
19-6 with conditions.
F.Conditional Use Permit (CUP 19-5)
3901 Lampson Avenue
Applicant:Frank Herrera
Request:Request for a Conditional Use Permit (CUP 19-5)to allow an interior
remodel to and existing banquette facility to reduce the size of an existing bar and
create an additional bar within the facility at the Old Ranch Country Club in the
Recreation/Golf (RG)Zone
Recommendation:After reviewing the application,staff recommends that the
Planning Commission adopt Resolution 19-13,APPROVING Conditional Use Permit
19-5 with conditions.
DIRECTOR'S REPORT
COMMISSION CONCERNS
ADJOURNMENT
Adjourn the Planning Commission to Monday,August 19,2019 at 7:00 p.m.
5
4
8
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
THRU:Gloria Harper, City Clerk
FROM:Steve Fowler, Interim Community Development Director
SUBJECT:Approval of the July 1, 2019 Minutes
RECOMMENDATION:Approve the minutes for the Planning Commission meeting
held on July 1, 2019
Prepared by: Approved by:
Gloria Harper Steve Fowler
Gloria Harper Steve Fowler
City Clerk Interim Director of Community Development
Attachment:
1. Minutes
City of Seal Beach – Planning Commission
July 1, 2019
Chair Campbell called the regular meeting of the Planning Commission to order at 7:01
p.m. in the City Council Chambers. Vice Chair Aguilar led the Pledge of Allegiance.
ROLL CALL
Present: Commissioners: Campbell, Aguilar, Klinger, Miller, Thomas
Absent: None
Staff Present: Amy Greyson, Assistant City Attorney
Steven Fowler, Interim Community Development Director
Dana Engstrom, Deputy City Clerk
APPROVAL OF AGENDA
Motion by Aguilar, second by Miller, to approve Agenda.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
ORAL COMMUNICATIONS
Chair Campbell opened oral communications. Speakers: There were no speakers. Chair
Campbell closed oral communications.
CONSENT CALENDAR
There were no consent calendar items.
CONTINUED ITEMS
There were no continued items.
SCHEDULED MATTERS
There were no scheduled matter items.
NEW BUSINESS
A. MINOR USE PERMIT (MUP 19-3)
101 A Surfside Avenue
Applicant: Otis Architecture Request: Request for a Minor Use Permit (MUP 19-3) to
permit a covered roof access structure to exceed the maximum roof height by 4 feet 6
inches on a proposed single family residence in the Residential Low Density (RLD-9)
zoning area.
Recommendation: After conducting the public hearing and receiving testimony, staff
recommends that the Planning Commission adopt the attached Resolution No. 19-8
approving MUP 19-3 with conditions.
Interim Community Development Director Steven Fowler provided a comprehensive staff
report and indicated no correspondence was received regarding the project. Mr. Fowler
answered questions from the Commission.
Chair Campbell opened the public hearing. Speakers: Karen Otis spoke about the project
and indicated the height was well below the requirements. Chair Campbell closed public
comment.
Motion by Aguilar, second by Thomas to adopt the attached Resolution No. 19-8 approving
MUP 19-3 with conditions.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
Commissioner Aguilar recused himself from Item B.
PUBLIC HEARINGS
B. CONDITIONAL USE PERMIT (CUP19-4)
15 1st Street
Applicant: Beach House LLC Request: Request for a Conditional Use Permit (CUP
19-4) to allow an existing restaurant with an outdoor eating area and an existing
type 41 (On-Sale Beer and Wine) alcohol license to upgrade to a Type 47 (On-Sale
General) alcohol license, and increase the currently permitted operating hours from
9 a.m. to 10 p.m. to the proposed hours of 7 a.m. to 10 p.m. 7 days a week. The
restaurant is located within the Beach (BEA) zoning area.
Recommendation: After conducting the Public Hearing, staff recommends that the
Planning Commission adopt the attached Resolution No. 19-7, to approve
Conditional Use Permit 19-4 with Conditions.
Interim Community Development Director Steven Fowler provided a comprehensive staff
report and indicated no correspondence was received regarding the project.
There was general discussion before and after the public hearing regarding the
discrepancy in the plans submitted to the City with the application (referenced as Plan A at
the meeting) and the plans submitted to Coastal Commission (referenced as Plan B at the
meeting) as well as how it affects the lease. Assistant City Attorney Amy Greyson clarified
that if the Commission approves the CUP they would be approving Plan A. Plan B is not
before the Commission, if the applicant wants the Commission to consider Plan B they
would have to amend their application. Amplified music and lighting was also discussed
and will be addressed at the staff level.
Chair Campbell opened the public hearing. Speakers: The applicant, Rosie Ritchie, spoke
on behalf of the Beach House LLC who submitted revised plans for the Commission
(referenced as Plan B at the meeting) that she submitted to the Coastal Commission. She
addressed questions from the Commission.
Brian Kyle, co-applicant of the Beach House, spoke regarding his frustration with the City
Attorney’s office and indicated they stayed within the footprint of the plans.
Art Valente, the designer of the Beach House, assured the Commission that the floor plans
have not changed just the elevations.
Jim Frymuth spoke in support of the hours and liquor license but expressed his concerns
regarding amplified music and bright signage.
Kurt Damire spoke in support of the hours and liquor license however he is concerned with
the lighting and amplified music.
Ray Longoria spoke in favor of the hours and liquor license and indicated that he feels like
the applicant is being treated unfairly.
Alan Shorlets spoke in favor of the Beach House.
Lisa Wearing questioned why this process is taking so long and suggested that everyone
sit down and have a meeting.
The Beach House Attorney Montgomery Cole indicated that he did not receive notification
of the meeting and disagreed with the position of the City Attorney regarding what the
Commission is voting on at this particular meeting.
Tony Bares spoke in support of the Beach House and the applicants.
Matt Johnson spoke in favor of the hours and liquor license.
Chair Campbell closed public comment.
Motion by Klinger, second by Miller to adopt the attached Resolution No. 19-7, to approve
Conditional Use Permit 19-4 with Conditions.
AYES: Klinger, Miller, Thomas
NOES: Campbell
ABSENT: None
ABSTAIN: Aguilar
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
DIRECTOR’S REPORT
Interim Community Development Director Steve Fowler had no comments.
COMMISSION CONCERNS
There were no Commission concerns.
ADJOURNMENT
Chair Campbell adjourned the Planning Commission meeting at 8:29 p.m. to Monday,
July 15, 2019 at 7:00 p.m.
___________________________
Gloria D. Harper, City Clerk
Approved: _______________________
Patricia Campbell, Chair
Attest: _______________________
Gloria D. Harper, City Clerk
5
4
8
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
THRU:Gloria D. Harper, City Clerk
FROM:Steve Fowler, Interim Community Development Director
SUBJECT:Approval of the July 15, 2019 Minutes
RECOMMENDATION:Approve the minutes for the Planning Commission meeting
held on July 15, 2019
Prepared by: Approved by:
Gloria D. Harper Steve Fowler
Gloria Harper Steve Fowler
City Clerk Interim Director of Community Development
Attachment:
1. Minutes
City of Seal Beach – Planning Commission
July 15, 2019
Chair Campbell called the regular meeting of the Planning Commission to order at 7:00
p.m. in the City Council Chambers. Commissioner Klinger led the Pledge of Allegiance.
ROLL CALL
Present: Commissioners: Campbell, Aguilar, Klinger, Miller, Thomas
Absent: None
Staff Present: Amy Greyson, Assistant City Attorney
Steven Fowler, Interim Community Development Director
Marcos Cuevas, Assistant Planner
Gloria D. Harper, City Clerk
APPROVAL OF AGENDA
Motion by Thomas, second by Aguilar, to approve Agenda.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
ORAL COMMUNICATIONS
Chair Campbell opened oral communications. Speakers: Bruce Bennett. Chair Campbell
closed oral communications.
CONSENT CALENDAR
A. Approval of May 20, 2019 Minutes
Motion by Aguilar, second by Klinger to approve the May 20, 2019 Minutes.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
PUBLIC HEARINGS
B. Conditional Use Permit (CUP 19-3)
715 Coastline Drive
Applicant: Shane and Autumn Igo
Request: Request for a CONDITIONAL USE PERMIT (CUP 19-3) to allow a 715
square foot 2nd floor addition to an existing 2,279 square foot single-family
residence with a 2 car-garage at a parcel that is nonconforming due to setbacks
located within the Residential Low Density (RLD-9) zoning area.
Recommendation: After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 19-9, APPROVING Conditional Use
Permit 19-3 with Conditions.
Interim Community Development Director Steven Fowler provided a comprehensive staff
report and indicated no correspondence was received regarding the project.
Chair Campbell opened the public hearing. Speakers: Autumn Igo introduced herself,
thanked the Commissioners and answered questions.
Chair Campbell closed public comment.
Motion by Thomas, second by Aguilar to adopt Resolution No. 19-9, APPROVING the
Conditional Use Permit (CUP 19-3) 715 Coastline Drive.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
C. CONDITIONAL USE PERMIT (CUP18-10)
1198 Pacific Coast Highway #E
Applicant: Michael Tomac
Request: Request for a CONDITIONAL USE PERMIT (CUP 18-10) to allow the
operation of a math tutoring business within an existing commercial suite located at
1198 Pacific Coast Highway, Suite E, within the General Commercial (GC) zoning
area.
Recommendation:
After conducting the Public Hearing, staff recommends that the Planning
Commission adopt Resolution No. 19-10, APPROVING Conditional Use Permit 18-
10 with Conditions.
Interim Community Development Director Steven Fowler provided a comprehensive staff
report and indicated no correspondence was received regarding the project.
Chair Campbell opened the public hearing. Speakers: Michael Tomac introduced himself,
thanked the Commission and answered question. Bruce Bennett.
Chair Campbell closed public comment.
Motion by Aguilar, second by Klinger, to adopt Resolution No. 19-10, APPROVING
Conditional Use Permit 18-10 with Conditions.
AYES: Campbell, Aguilar, Klinger, Miller, Thomas
NOES: None
ABSENT: None
ABSTAIN: None
Motion Carried
Assistant City Attorney Greyson noted that the ten-day appeal period starts tomorrow.
DIRECTOR’S REPORT
Interim Community Development Director Steven Fowler had no comments.
COMMISSION CONCERNS
Commission had no comments
ADJOURNMENT
Chair Campbell adjourned the Planning Commission meeting at 7:39 p.m. to Monday,
August 5, 2019 at 7:00 p.m.
___________________________
Gloria D. Harper, City Clerk
Approved: _______________________
Patricia Campbell, Chair
Attest: _______________________
Gloria D. Harper, City Clerk
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
FROM:Steve Fowler, Interim Community Development Director
SUBJECT:Request for Minor Use Permit (MUP 19-5) to allow the interior
remodel and exterior remodel of an existing two-story single-
family residence that is nonconforming due to setbacks and
interior garage size in the Residential High Density (RHD-20)
zoning area.
LOCATION:228 13th Street
APPLICANT:OTIS ARCITECTURE
RECOMMENDATION:After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 19-12, APPROVING
Minor Use Permit 19-5 with Conditions
GENERAL PLAN
DESIGNATION:
RESIDENTIAL HIGH DENSITY
ZONE:RHD-20 (RESIDENTIAL HIGH DENSITY)
SITE DESCRIPTION:ASSESSOR’S PARCEL NUMBER: 043-134-23
LOT AREA: 3,750 sq. ft.
GROSS FLOOR AREA: 3,417 sq. ft.
SURROUNDING PROPERTIES:
NORTH: RESIDENTIAL HIGH DENSITY (RHD-20)
SOUTH: RESIDENTIAL HIGH DENSITY (RHD-20)
EAST: RESIDENTIAL HIGH DENSITY (RHD-20)
WEST: RESIDENTIAL HIGH DENSITY (RHD-20)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of the remodel at an existing nonconforming two-
story single-family residence that only requires minor modification to complete the work.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on July 25,
2019 and mailed to property owners and occupants within a 300’ radius of the subject property
on July 25, 2019, with affidavits of publishing and mailing on file.
VICINITY MAP: AERIAL MAP:
ANALYSIS
The applicant, Otis Architecture, on behalf of Stefan and Mihaela Schneider, (“the
owners”) filed an application with the Community Development Department for Minor
Use Permit 19-5. The subject site is a 3,750 square foot parcel located on the east side
of 13th Street between Electric Avenue and Landing Avenue in The Old Town area
within the RHD-20 (Residential High Density) zoning area. The lot is currently
developed with a two story residence. The subject site is in the Residential Low Density
(RHD-20) zoning area and is surrounded by residential uses on all sides.
The subject property is nonconforming due to setbacks, and parking. According to Table
11.2.05.015 of the Seal Beach Municipal Code, interior side yard setbacks on properties
in the RHD-20 zoning area are required to be 10 percent of the property width or a
minimum 3 feet. The width of the property is 37 feet 6 inches so the interior side yard
setback on both sides of the residence is required to be 3 feet 9 inches is currently only
3 feet.
According to Table 11.4.20.015 of the Seal Beach Municipal Code, residential uses in
the RHD-20 zone are required to provide 2 off-street parking spaces per dwelling unit,
with an interior dimension of 18 feet wide by 18 feet deep. The subject site contains one
dwelling unit with a garage that is 19 feet deep by 17 feet 4 inches wide. The garage is
deficient in size by 8 inches.
The applicant is proposing to remove and relocate interior walls in the residence to
provide a more usable floor plan and reorganize the closet and bathroom space. The
Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor improvements which
involve the removal or alteration to less than 25% of a structure’s interior walls, provided
the bedroom/bathroom ratio does not exceed one and one-half bathrooms for each
bedroom with approval of a Minor Use Permit. The applicant does not propose to add
any additional bedrooms or bathrooms to the existing residence and will keep the
residence in conformance with this provision. The alterations proposed on the subject
site are consistent with the provisions of this code.
CONCLUSION
After conducting the public hearing and receiving testimony, staff recommends that the Planning
Commission adopt the attached Resolution No. 19-12 approving MUP 19-5 to allow the interior
remodel and exterior remodel of an existing two-story single-family residence that is
nonconforming due to setbacks and interior garage size at 228 13th Street.
Prepared by:
Steve Fowler
Steve Fowler
Interim Director of Community Development
Attachments:
1. Resolution No. 19-12 – A Resolution of the Planning Commission of the City of Seal
Beach, Approving Minor Use Permit 19-5, to allow the interior remodel and exterior
remodel of an existing two-story single-family residence that is nonconforming due to
setbacks and interior garage size at 228 13th Street.
2. Project architectural plans.
Page 1 of 3
RESOLUTION NO. 19-12
A RESOLUTION OF THE PLANNING COMMISSION OF THE
CITY OF SEAL BEACH APPROVING MINOR USE PERMIT 19-5
TO ALLOW THE INTERIOR REMODEL AND EXTERIOR
REMODEL OF AN EXISTING TWO-STORY SINGLE-FAMILY
RESIDENCE THAT IS NONCONFORMING DUE TO SETBACKS
AND INTERIOR GARAGE SIZE IN THE RESIDENTIAL HIGH
DENSITY (RHD-20) ZONED AREA AT 228 13TH STREET.
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES HEREBY
RESOLVE:
Section 1. Otis Architecture (“the applicant”) on behalf of Stefan and Mihaela
Schneider (“the owners”,) submitted an application to the Community Development Department for
Minor Use Permit 19-5. The proposed project includes the interior remodel of the existing residence
to provide a more usable floor plan and to reorganize the closet and bathroom space at a property
that is nonconforming due to setbacks and garage size located in the Residential High Density (RHD-
20) zoning area.
Section 2. This project is determined to be a Class 1 (Existing Facility) Categorical
Exemption pursuant to Section 15301 of the Guidelines for the California Environmental Quality Act
(Public Resources Code Section 21000 et seq.) for the permitting of the remodel at an existing
nonconforming two-story single-family residence that only requires minor modification to complete the
work.
Section 3. A duly noticed public meeting was held before the Planning Commission
on August 5, 2019 to consider Minor Use Permit 19-5. At the public meeting, the Planning
Commission received into the record all evidence and testimony provided on this matter. The record
of the hearing indicates the following:
A.The applicant submitted an application to the Community Development
Department for Minor Use Permit 19-5 for a proposed project at 228 13th Street, Seal Beach,
California.
B.The subject property is rectangular in shape with a lot area of approximately
3,750 square feet. The subject property has a lot width of 37.5 feet with a lot depth of 100 feet. The
site is surrounded by residential uses on the all sides.
C.The subject property is currently developed with a two-story single family
residence with an attached two-car garage. Because the setback on the interior side yard setbacks
does not meet the minimum required setback and the garage does not meet the minimum interior
width of a two-car garage, the subject property is considered nonconforming. The proposed
improvements will not expand any existing nonconformity because the proposed remodel will not
expand the existing footprint.
D.The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor
improvements which involve the interior remodel of less than 25 percent of the walls through the
approval of a Minor Use Permit. The applicant is requesting to remodel the interior of the residence to
provide a more usable floor plan and to reorganize the closet and bathroom space.
Section 4. Based upon the facts contained in the record, including those stated in
the preceding Section of this resolution and pursuant to Chapter 11.5.20 of the Seal Beach Municipal
Code, the Planning Commission makes the following findings:
A.The proposed minor improvements are consistent with the General Plan which
encourages architectural diversity in the Old Town area (Planning Area 1) while ensuring compatibility
between residential and commercial uses. The General Plan also recognizes existing nonconforming
Resolution 19-12
228 13th Street
Page 2 of 3
land uses and permits minor alterations. The proposed remodel to provide a more usable floor plan
and reorganize the closet and bathroom space of the existing residence will not change the character
of the property, will not expand any nonconformity, and will be consistent with other surrounding
properties.
B.The proposed use is allowed within the applicable zoning district with Minor Use
Permit approval and will comply with all other applicable provisions of the Municipal Code. The
subject site is located within the Old Town RHD-20 zone, an area where the Seal Beach Municipal
Code (Section 11.4.40.015.B) allows minor improvement which involves a remodel to provide a more
usable floor plan and reorganize the closet and bathroom space with approval of a Minor Use Permit.
C.The proposed use, as conditioned below, will be located on a site that is
physically adequate for the type, density, and intensity of use being proposed, including provision of
services, and the absence of physical constraints. The subject site is currently developed with a two-
story single-family residence and is considered nonconforming due to setbacks and garage size. The
remodel to provide a more usable floor plan and reorganize the closet and bathroom space will not
add habitable space and will maintain development standards applicable to the RHD-20 zone. The
improvement will not increase density or change beyond existing use of the property.
D.The location, size, design, and operating characteristics of the proposed use,
as conditioned below, will be compatible with and will not adversely affect uses and properties in the
surrounding neighborhood. The subject site is located within the RHD-20 zone, which consists of
properties developed as single family and multi-family residences. The improvement will not add
habitable space, will not change existing operating characteristics of the single-family residence, and
will remain similar to surrounding uses throughout RHD-20.
E.The establishment, maintenance, and operation of the proposed use will not be
detrimental to the health, safety, or welfare of persons residing or working in the vicinity. The remodel
to provide a more usable floor plan and reorganize the closet and bathroom space will not increase
bedrooms, exceed the bedroom/bathroom ratio authorized under the development standards, or
intensify use on the property. The subject site will continue to operate as a residential property, which
is consistent with the uses in the surrounding neighborhood.
Section 5. Based on the foregoing, the Planning Commission hereby approves
Minor Use Permit 19-5 for the remodel to provide a more usable floor plan and reorganize the closet
and bathroom space within an existing single-family residence that is nonconforming due to setbacks
garage size is subject to the following conditions:
1. Minor Use Permit 19-5 is approved for the remodel to provide a more usable floor plan and
reorganize the closet and bathroom space of the existing single-family residence on the
nonconforming property located at 228 13th Street.
2. All plan check and future construction shall be in substantial compliance with the plans
approved through Minor Use Permit 19-5. All new construction shall comply with all applicable
state and local codes.
3. The applicant is required to obtain all Building and Safety permits prior to construction or
demolition.
4. All materials, color, and finishes of the wall finish will be consistent with existing roof pitches
and exterior finishes of the residential dwelling.
6. This Minor Use Permit shall not become effective for any purpose unless an “Acceptance of
Conditions” form has been signed, notarized, and returned to the Community Development
Department; and until the ten (10) day appeal period has elapsed.
Resolution 19-12
228 13th Street
Page 3 of 3
7. The applicant shall indemnify, defend and hold harmless the City, its officers, agents and
employees (collectively “the City” hereinafter) from any and all claims and losses whatsoever
occurring or resulting to any and all persons, firms, or corporations furnishing or supplying
work, services, materials, or supplies in connection with the performance of the use permitted
hereby or the exercise of the rights granted herein, and any and all claims, lawsuits or actions
arising from the granting of or the exercise of the rights permitted by this Minor Use Permit,
and from any and all claims and losses occurring or resulting to any person, firm, corporation
or property for damage, injury or death arising out of or connected with the performance of the
use permitted hereby. Applicant’s obligation to indemnify, defend and hold harmless the City
as stated herein shall include, but not be limited to, paying all fees and costs incurred by legal
counsel of the City’s choice in representing the City in connection with any such claims,
losses, lawsuits or actions, expert witness fees, and any award of damages, judgments,
verdicts, court costs or attorneys’ fees in any such lawsuit or action.
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning Commission at a
meeting thereof held on August 5, 2019, by the following vote:
AYES: Commissioners
NOES: Commissioners
ABSENT: Commissioners
ABSTAIN: Commissioners
Patricia Campbell
Chairperson
ATTEST:
__________________________
Steve Fowler
Planning Commission Secretary
Revisions:By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:09 AM0T-1Schneider Residence228 13th StreetSeal Beach, CA 90740Title SheetAPPLICABLE CODES:2016 CALIFORNIA RESIDENTIAL2016 CALIFORNIA PLUMBING CODE2016 CALIFORNIA MECHANICAL CODE2016 CALIFORNIA ELECTRICAL CODE2016 CENERGY CPDE AND 2010 TITLE 242016 CA RESIDENTIAL CODE2016 GREEN CODEREGULATIONS AND CITY ORDINANCESNOTE:EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.NOTE:SEPARATE PERMIT(S) IS/ARE REQUIRED FOR ACCESSORY BUILDING, PATIO COVERS, WALLS, SWIMMING POOLS, RETAINING WALL DEMOLITON, ETC.NOTE:ARCHITECT SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSED PRIOR TO ISSUANCE OF BUILDING PERMITS.NOTE:SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR EQUIPMENT IN THE PUBLIC WAY. NOTE:SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY ANY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY THE RAIN OR OTHER MEANS.NOTE:THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING THE CORRECTION OF ERROR ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY. RELEVANT LAWS, ORDINANCES, REULES, AND/OR REGS.NOTE:SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQM) SHALL BE NOTIFIED IN ACCORDANCE WITH CA STATE LAW PRIOR TO START OF ANY DEMOLITION, ADDITION AND/OR REMODEL WORK. THE SCAQM DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DR. DIAMOND BAR, CA. PHONE (909) 296-2000BE ADVISED: SCAQM MAY REQUIRE A 10-DAY WAIT PERIOD PRIOR TO START OF WORK.NOTE:ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA TITLE 24 REGARDLESS OF INFORMATION INDICATED ON THESE PLANS. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS PRIOR TO REQUESTING INSPECTION.NOTE:AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID WORKERS COMPENSATION INSURANCE CERTIFICATE.NOTE:STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALIS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY FORCES OF WIND AND WATER.NOTE: TRASH AND OTHER CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.NOTE:FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATER. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. DESCRIPTIONMIN. FRONT SETBACK12'-0" AVGNO CHANGE-SETBACK MAINTAINEDMIN. REAR SETBACK24'-0" MINUS ALLEYNO CHANGE-SETBACK MAINTAINEDSIDE SETBACK3'-7"3'-0" EXISTING, NON CONFORMINGMAX. HEIGHT25'-0"NO CHANGE-MAX HT. MAINTAINEDPROPERTY DEVELOPMENT STANDARDSREQUIREDPROVIDEDSCHNEIDER RESIDENCE228 13TH STREET, SEAL BEACH, CA 90740APN: 043-134-23PROJECT INFORMATION:BUILDING CODE DATA:USE: SFR OCCUPANCY TYPE: R-3/UCONSTRUCTION TYPE: REMODELFIRE SPRINKLERS: NOSTORIES: 2LOT INFORMATION:ZONING: RHD-20LOT AREA: 2,800 SFLOT COVERAGE: 75%SCOPE OF WORK:REMODEL OF EXISTING TWO STORY HOME, TO INCLUDEMASTER BATH, NEW POWDER ROOM, AND MISCELLANEOUS INTERIOR FINISHES. SOME NEW WINDOWS TO MATCH EXISTING AND FRONT FACADE REMODEL.SQUARE FOOTAGESFIRST FLOOR: 1,638 SF (NO CHANGE)SECOND FLOOR: 1,409 SF (NO CHANGE)BEDROOMS AND BATHROOMS:TOTAL BEDROOMS: 4TOTAL BATHROOMS: 3 FULL, 1 HALFTOTAL HABITABLE: 3,047 SF(NO CHANGE)PATIOS:72 SFGARAGE:370 SFVICINITY MAP:CONTACT INFORMATION:ARCHITECTOTIS ARCHITECTUREKAREN OTIS909 ELECTRIC AVE. STE 207SEAL BEACH, CA 90740714. 846. 0177CLIENTSTEFAN AND MIHAELA SCHNEIDER228 13TH STREETSEAL BEACH, CA 90740stefan@drschneiderid.comTITLE 24ENERGY CODE WORKS2600 MICHELSON DR. #1700800. 700. 0131REP: MARK MADISONSheet Index0T-1 TITLE SHEET0T-2 GENERAL NOTESA-1.0 SITE PLANA-1.1 DEMO PLANSA-1.2 PROPOSED PLANSA-2.1 EXTERIOR ELEVATIONSA-2.2 EXTERIOR ELEVATIONSA-3.1 INTERIOR ELEVATIONSA-4.1 DOOR AND WINDOW SCHEDULEA-5.1 DETAILS1
Revisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:09 AM0T-2DIVISION 1 - GENERAL REQUIREMENTS:1-A. ARCHITECT'S STATUS:The Architect does not guarantee the Contractor's performance, and no provisions of the contract documents shall relieve the Contractor from any liability due to negligence, incompetence or errors of omissions or commission of the Contractor.The drawings and specifications represent the finished structure. The design adequacy and safety of erection, bracing, shoring, temporary supports, etc. is the sole responsibility of the Contractor, and has not been considered by the Architect or the Structural Engineer. The contractor is responsible for the stability of the structure prior to the application of all shear wall, roof and floor diaphragms and finished materials. He shall provide the necessary bracing to provide stability prior to the application of the aforementioned materials.Observation visits to the job site by the Architect do not include inspection of construction procedures. The Contractor is solely responsible for all construction methods and for safety conditions at the worksite. These visits shall not be construed as continuous and detailed inspections.Design, materials, equipment and products other than these described below or indicated on the drawings may be considered for use, provided prior approval is obtained from the Architect and applicable governing code authority.On site verification of all dimensions and conditions shall be the responsibility of the Contractor. Written dimensions shall take precedence over scaled dimensions, existing dimensions take precedence over written dimensions.1-B. CODESAll codes having jurisdiction shall be observed strictly in the construction of the project including all applicable state, city, and county building, zoning, electrical, mechanical, plumbing and fire codes. The Contractor shall verify all code requirements before the commencement of construction and bring any discrepancies between code requirements and the construction documents to the attention of the Architect.1-C. ERRORS AND OMISSIONS:Errors, omissions, or conflicts which may occur in Construction Documents shall be brought to the attention of the Architect in writing and written instructions shall be obtained before proceeding with the work. The Contractor will be held responsible for the result of any errors, discrepancies, or omissions of which the Contractor failed to notify the Architect before construction and/or fabrication of the work.1-D JOB CONDITIONS:The Contractor and Subcontractor shall verify all dimensions and job conditions at the job site sufficiently in advance of work to be performed to assure the orderly progress of the work. The Architect shall be notified of any discrepancy.DIVISION 2 - SITE WORK2A. DEMOLITION:Contractor to complete all demolition work as shown on the drawings. Cap, terminate, and reconnect plumbing and electrical utilities impacted by demolition work. Execute all demolition work in an orderly manner with due consideration for any existing structures, including any parts of the surrounding area which are to remain. Barricade and cover as necessary to protect pedestrians, workmen, and adjacent properties. Protect any existing active service lines, indicated or not. Back fill any trenches caused by demolition work. Contractor to maintain cleanliness and security on site.2-B SOILS AND FOUNDATION:Perform all work in this section in conformance with the soils figures and/or reports approved by the Building Department. The location of and protection of all utilities is the Contractor's responsibility.DIVISION 3 - CONCRETEIt shall be the responsibility of the Contractor to locate all existing utilities whether shown hereon or not and to protect them from damage. The contractor shall bear all expense of repair or replacement in conjunction with the prosecution of this work.3-A. FOUNDATION:Location of construction or pour joints must be approved by the Structural Engineer. All pipes or ducts through concrete shall be sleeved. Pipes or ducts exceeding one third the slab or wall thickness shall not be placed in structural concrete unless specifically detailed by Structural Engineer. Foundation below ground shall be made watertight and damp proof. Refer to structural drawings for details and specifications.3-B WORKMANSHIP:All work shall comply with the requirements set forth in the "Manual of Standard Practice for Detailing Reinforced Concrete Structures," published by the American Concrete Institute except where more exacting requirements are specified in the Construction Documents.1. All bending of reinforced steel shall conform to the latest edition of the Uniform Building Code.2. Anchor Bolts shall be manufactured of ASTM A307 steel and placed per Engineer's specifications.DIVISION 4 - MASONRY:4-A. GENERAL:Provide labor, materials, equipment, and other services to complete masonry where indicated on drawings. Walls shall be straight, plumb, and true, with all courses true to line and level, to dimension shown. Cells shall be filled solid with grout as indicated. Blocks shall be laid up with waterproof Type M or S mortar. Clean units before replacing. Use masonry saw for cutting.DIVISION 5 - METALS5-A. WORKMANSHIP:All work shall comply with A.I.S.C. Manual of Steel Construction, latest edition. Welding to be done per American Welding Society Structural Weld Code. All field welding shall be performed by a county or city approved welder and inspected and approved by a deputy inspector.5-B. MISCELLANEOUS ITEMS:Miscellaneous metal items and their related components are not necessarily individually described. The most important and those requiring detailed description are specified. Miscellaneous items not described shall be furnished and installed in accordance with the intent of the drawings and specifications and as required to complete work. Shop drawings to be submitted for Architect's approval prior to fabrication.DIVISION 6 – WOOD6-A. ROUGH CARPENTRY:1. All structural lumber shall be grade marked and conform with the standard grading and dressing rules of the Western Wood Products Association.2. All wood resting on concrete or within 6 inches of finish grade shall be pressure treated Douglas Fir. 3. Fireblocking: Fire block stud walls and partitions (including furred spaces) at the floor, ceiling, soffit, and at mid-height of walls over 0'-0" in height.4. Roof Sheathing: 1/2"CDX Plywood Index 3224 PS 1-95. Nail with 10d nail at 6" OC at intermediate supports. Lay panels with face grain across supports. Stagger panel joints. Nailing shall be inspected prior to covering.5. Blocking: Provide 2X solid blocking between joist or rafters at all supports.6. Wood Trusses: It shall be the responsibility of the manufacturer to obtain Building Department approval of Calculations and shop drawings prior to fabrication. The manufacturer shall be an Approved Fabricator, as currently listed by ICBO. Trusses shall be designed in accordance with the latest Building Code for all loads imposed, including lateral loads and mechanical equipment loads. 7. New subfloor to be 1-1/8"plywood unless remodel condition does not permit.6-B. MILLWORK:Manufacture millwork and casework per Manual of Millwork Institute of California, custom grade unless noted otherwise. Install all shelving, casework, millwork, doors, hardware, railing, trim, counters, utility backboards and other finish carpentry. All maple cabinets and surfaces to be sealed prior to stain or color lacquer in order to prevent irregular color absorption into wood.6-C. CABINETS:1. 3/4 " Solid wood (see plans for wood specification)2. Melamine cabinet interior3. Concealed European hinges4. 5mm holes at sides of cabinets for adjustable shelves.5. 9-ply maple at drawers with lock joints and European side guides.6. Melamine and alder at pull-out trays with European side guides.7. Alder interior pull-out trash tray with drop-in 32 qt. trash can pull extension guides.Cabinet fabricator to submit shop drawings prior to fabrication. Verify all dimensions and finishes with owner.DIVISION 7 - THERMAL AND MOISTURE PROTECTION7-A. ROOFING:Shall be installed per CBC and in accordance with the manufacturer's listing. Refer plans for manufacturer.7-B. SHEET METAL:Verify all dimensions shown on drawings by taking field measurements; proper fit and attachment on all parts is required. All work included in this section shall be performed in accordance with the recommendation contained in the latest edition of the manual "Suggested Specifications for Architectural Sheet Metal Work," published by the Sheet Metal and Air Conditioning Contractor's National Association.7-C INSULATION:Shall be provided and installed per Title 24, California Administrative Code. Dwelling units shall receive a minimum of R19 blanket insulation at roofs and R11 at walls. Unless noted otherwise, provide thermal insulation in all exterior and interior stud walls and ceilings, extending full height of walls, fitted tightly between studs.DIVISION 8 - DOORS AND WINDOWS8-A. WOOD DOORS:All doors shall comply with the requirements of the woodwork Institute of California, standard grade (CBC) : Title 24, California Administrative Code.8-B. DOORS AND WINDOWS:All exterior windows and glass door shall comply with T-24 calculations: Refer to T-24 Report. Finish per owner's specifications. Caulk at exterior. Provide aluminum framed fiberglass screen at each open vent. Glazing shall be sized per U.B.C. Tempered glass shall be installed when required by CBC8-C. SECURITY:1. Exterior doors and their hardware shall conform to the security provisions of the applicable chapter of CBC and local city codes.2. All exterior doors and lower leaf of Dutch door shall have dead bolt and dead locking latch, both key operated from the outside. Deadbolts shall have a hardened insert with 1" min. throw and 5/8" min. embedment into jamb. Inactive leaf shall have flushbolts top and bottom with 1/2" embedment exterior door hinge pins shall be non-removable.3. Overhead and sliding doors shall be secured with a cylinder lock padlock with hardened steel shackle or slide bolt.DIVISION 9 - FINISHES9-A. GYPSUM DRYWALL CONSTRUCTION:1. Scope: Furnish and install all gypsum wallboard work complete.2. Standards: a.All work and materials shall comply with the applicable chapter of CBC. b.All work and materials shall comply with American Standard Association's "Specification for Gypsum Wallboard Finishes".3. Materials: a.5/8" gypsum wallboard typical throughout. b.5/8" gypsum wallboard "greenboard" typical at all plumbing walls. c.Tape and Compound: As recommended by gypsum board Manufacturer. d.Attachments: Screw attachments per code.4. Installation: Installation and finishing shall conform to American Standard A97.1- 65 and as specified herein: a.Wallboard: Apply wallboard first to ceilings and then to walls, horizontally. Use board of maximum practical lengths and stagger end joints. Apply metal edge trim to all exposed gypsum board edges and outside corners. b.Finishing: Tape and finish joints, corners and edges in accordance with Manufacture's recommendations. Leave surfaces smooth, free of visible joints, nail holes and sanding marks. c.Finish Textures: Smooth no texture- feather all joints with special care. d. All Slate and/or Stone: Clean and seal prior to grouting.9-B.STUCCO:1. Reference Specifications: Lathing materials and their application and plaster materials and their application shall be in strict accordance with the applicable sections for Lathing, Furring and Plastering of the National Gypsum Association.2. Building Paper: Install Type 15 felt or other approved. Under exterior trim and siding apply so as to form a watertight membrane. Overlap each course below 2 inches minimum horizontal joints and 6 inches minimum at vertical joints.3. Flashing at Wall Penetrations: Install sisalkraft paper as flashing in a weatherboard fashion. Slip window under horizontal head sisalkraft and secure metal window and door fin over sealant on interface of fins at side and bottom. Note: Provide a bead of Butyl sealant on interface of fins at side and bottom, also exterior face of top fin, before inserting metal frames. 9-C. PAINTING:1. Application of paint or other coating shall be in strict accordance with manufacture's directions. Ready-mixed paint shall not be thinned, except as permitted in the application instructions.2. Top and bottom of all doors to be sealed and painted.3. All surfaces to be finished shall be clean and free of foreign materials (dirt, grease, asphalt, rust, etc.)4. Application shall be in a workmanlike manner providing a smooth surface. Application rate shall be that recommended by the manufacturer. Application may be by brush or roller or by spray if paint is formulated for spray application.5. All stucco finish to be painted with elastomeric paint or equivalent.6.Exterior wood to be properly flashed and caulked, and all nail and staple holes filled.7. All exposed paint grade wood to have 2 coats of primer and 2 coats of acrylic paint finish unless otherwise specified. All stain grade wood to be filled, sanded, and sealed with specified stain and finish. All interior wood to be sprayed, all other rolled or brushed.8. All metal surfaces and joints to be sealed prior to paint. All exposed metal to be properly primed with red- oxide. Apply 2 coats of paint and 1 coat of clear sealer.DIVISION 11 - EQUIPMENT (APPLIANCES)11-A. MEASUREMENTS:Verify all dimensions shown on the Drawings by taking field measurements; proper fit and attachment of all parts is required. Notify Architect if any discrepancies appear.DIVISION 15 - MECHANICAL: 15-A. HEATING:1. Rules and Regulations: All work and materials shall be in full accordance with the latest federal, state, and local codes and regulations. Nothing in these plans or specifications shall be construed to permit work not conforming to these codes.2.Materials and Equipment: Ductwork shall comply with the minimum weight standards as set forth in the California Building Code and the return ducts shall be galvanized sheet metal. Ducts and fittings shall be insulated with fiberglass. Provide automatic fire dampers where required.3. Fabrication and Installation : Furnace closets shall be sized to provide per CBC clearances from furnace unit at sides, front, rear, and other requirements per CBC and local codes.15-B. VENTILATION:1. Rules and Regulations: All work and materials shall be in full accordance with the latest CBC and local codes.2. Materials and Equipment: Provide mechanical exhaust ventilation, five air changes per hour for bathrooms containing a bathtub or shower or combination thereof, laundry rooms and similar rooms. Two air changes per hour are required in all guest rooms, habitable rooms and public corridors. Bathrooms which contain only a watercloset or lavatory or combination thereof may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors.15-C. PLUMBING:1. Copper to Steel Connections: All copper pipe connections to ferrous piping shall be made with dielectric coupling or isolation flanges. All waste lines between floors to be cast iron.2. Waste and Vent Systems: All soil, waste, and vent piping shall be approved ABS or cast iron. All horizontal plumbing between floors to be cast iron. All piping shall be sized as r equired by CBC or local codes. Cleanout locations shall be located in least visible areas. Provide cleanouts as required by CBC. Waste lines adjacent to living areas shall be cast iron for noise abatement.3. Domestic Water Piping System: All water supply lines shall be copper. Type L below slab and Type M above slab. Not fitting shall occur below slab. All hot water lines to be properly insulated.4.Water Heating System: Furnish, install and connect piping and equipment required to complete the water heating system.5. Domestic Gas Service: Provide gas line to gas-fired equipment including water heater, pool equipment, furnaces. Plumbing to be recessed in wall.6. Plumbing Fixtures and Equipment:a.General: Furnish and install all fixtures and equipment shown on the drawings or specified herein. All exposed brass tubing supplies, cast brass traps, hose bibs, waste pieces and other brass trim shall be heavily polished chrome plated. Finish all piping through walls, floors or ceiling with chrome plated wall flanges or escutcheons.b. Compression stops, strainers, tall pieces, trim etc., are included to make a complete fixture, whether or not specified. Provide approved one-piece waste overflow and trap unit with glued fittings at tubs.c. Galvanized pipe shall not be used for waste or water supply.d. Water supply lines shall be installed with approved anti-sound devices where required.DIVISION 16 - ELECTRICAL:16A.-GENERAL:Electrical system layouts are generally diagrammatic, location of outlets and equipment is approximate. Exact routing of wiring, location of outlet to be governed by structural conditions and constructions. Wiring for equipment requiring maintenance and inspection to be readily accessible.1. Conduit piping located within planting areas shall be placed a minimum of 18 inches below finished grades.2. Labeling: All electrical equipment, main and sub-panel breakers and time clock controls shall be properly labeled.3. Materials: Materials and equipment shall be new and listed by Underwriter's Laboratories Inc., and bear their label wherever standards have been established and their service is regularly furnished. All electrcal equipment shall be listed, labeled, and installed as per a recognized electrical testing labs standards.4. Miscellaneous Electrical Notes:a. Verify and locate receptacles prior to installation of drywall.b. Install receptacles at 1'-0" to center line above finish floor unless otherwise noted.c. Install light swiches at 3'-8" to center lines above finish floor unless otherwise noted.d. All swiched outlets shall be one-half hot.e. Locate receptacles in accordance with California Building Code.f. All exterior outlets, outlets in garages, outlets in bathrooms and outlets within 6 feet of kitchen sink or utility sink shall be a ground fault interrupter (or GFI).g. All switches and outlets to be Decora unless otherwise specified.h. All recessed down lights to be HALO unless otherwise specified.16-B. SOUND SYSTEM:Confirm with Owner sound system location, wiring and components, include into bids as directed.16-C. SECURITY SYSTEM:Confirm with Owner security system location, wiring and components, include into bids as directed.ROOF DECK SURFACINGFLOOR DRAINS -Note to Specifier: Floor drains, clean-outs, etc. should be of the "floor-flange" type as manufactured for use with composition floors by most major drain manufacturers. Drain flange shall be finished flush with substrate.SHEET METAL FLASHING-Note to Specifier: Sheet metal flashing shall be minimum 26 gauge galvanized. All joint or seems shall be overlapped approx. 3" and caulked with Dex-O-Tex Elastex 500 flashing paste or approved equal.PLYWOOD SUBSTRATE INCLUDING FRAMING AND BLOCKING-Note to Specifier: Plywood shall be a minimum 5/8" (preferably 3/4 inch) exterior grade plugged and sanded or filled with Dex-O-Tex G-26 Underlayment. Plywood shall be supported 16" on center and properly blocked. Plywood shall be attached with either screws, screw type or ring shank nails.SLOPE FOR DRAINAGE-Note to Specifier: Slope of 1/4 inch per horizontal foot to drain is recommended. A slope to drain of less than 1/4 inch per horizontal foot may result in water ponding on the deck surface and must be designed to show that adequate slope exists to prevent ponding. This can be provided for in the substrate or by application of Dex-O-Tex G 26 Underlayment. Care must be taken to provide adequate elevation at thresholds to provide proper slope to drain.Schneider Residence228 13th StreetSeal Beach, CA 90740General Notes
228 13TH STREET12'- 0" PROVIDED SETBACK100' LOT LENGTH37'-6" LOT WIDTHALLEYTHIRTEENTH STREET6' - 0"9' - 10"8' - 2"13' - 1 1/2"18' - 0"12'- 0" REQU'D AVG SETBACK3'- 0" REQU'D SETBACK3'- 0" PROV'D SETBACK9'- 0" REQU'D SETBACK3'- 0" NON CONFORMING SETBACK15'- 0" ALLEY WIDTH24'- 0" REQU'D SETBACK (INCL. ALLEY WIDTH)10'- 7" PROV'D SETBACK25'- 7" PROV'D SETBACK (INCL. ALLEY WIDTH)PLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDSRevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:10 AMA-1.0Schneider Residence228 13th StreetSeal Beach, CA 90740Site Plan1/4" = 1'-0"1SITE PLAN
DNGARAGE19' X 17'-4"KITCHENDINING12'-10" X 10'-1"LIVING17'-1" X 25'-2"BEDROOM 111'-10" X 10'-3 1/2"BATH 1CLOSETCLOSETFURNACEA-3.17IE-04.1WALL TO BE DEMOLISHED AND REPLACED BY NEW CABLE RAILING, SEE D-1OPEN TO BELOWOPEN TO BELOWMASTER BEDROOMMASTER BATHOFFICELAUNDRYLANDINGCLOSETCLOSETBEDROOM 311'-8" X 10'-3"BEDROOM 212'-4" X 9'-10 1/2"BATH 2BALCONYMASTER CLOSETPLAY NOOK ABOVE TO BE ELIMINATED(e)BALCONY TO BE DEMOLISHED(e) DOOR TO BE REMOVED AND REPLACED BY THREE NEW WINDOWS, SEE A-2.1/E-01 PLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDS1/4" = 1'-0"1Demo FLOOR 11/4" = 1'-0"2Demo FLOOR 2Schneider Residence228 13th StreetSeal Beach, CA 90740Demo PlansRevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:10 AMA-1.111
DNA-2.1A-2.2A-2.203040218' - 4"20' - 2"17' - 8 1/2"7' - 6 1/2"25' - 1"6' - 7 3/4"GARAGE19' X 17'-4"KITCHENDINING12'-10" X 10'-1"6' - 6 3/4"10' - 3 1/2"LIVING17'-1" X 25'-2"BEDROOM 111'-10" X 10'-3 1/2"BATH 1CLOSET(e)FURNACE(e) 4'-2" x 2'-5" WINDOW OPENING TO BE FILLED, REPLACED WITH (n) WINDOW, SEE A-4.16' - 7"1' - 0 3/4"1' - 0 3/4"A-5.101A-5.102A-5.107020104207201201204101102203005001EXISTING DOOR TO BE REPLACED BY NEW DOOR WITH SIDELIGHTEXISTING COLUM TO REMAIN, TO BE FURRED & WRAPPED WITH WOOD LIKE TILE01NO WORKNO WORKNO WORKNO WORKNO WORK(e) STAIRCASEA-3.17IE-04.1(e) FIREPLACEA-5.109(n) POWDER2' - 9 1/4"208030517181920212' - 9 1/4"1' - 4 1/2"A-2.1A-2.2A-2.203A-2.10104024' - 11"OPEN TO BELOWOPEN TO BELOWMASTER BEDROOM12'-6" X 13'-3"MASTER BATH8'-8" X 11'-5"OFFICE10'-1" X 9'-4"LAUNDRYLANDINGCLOSETBEDROOM 311'-8" X 10'-3"BEDROOM 212'-4" X 9'-10 1/2"BATH 2BALCONY12' - 6"1'-6" x 3'-0"FURNACE CLOSETNEW CLERESTORY WINDOW TO MATCH EXISTING ABOVE DOORSEE ELEVATIONS FOR WINDOW TAG16' - 3 1/4"11' - 5 3/4"8' - 0 3/4"7' - 0 3/4"3' - 0 1/4"(e) 4' x 4' WINDOW OPENING, TO BE FILLEDMASTER CLOSET8'-0" X 7'-0"REMOVAL OF EXISTING PLAY NOOK ABOVE4' - 0 1/2"4' - 0 1/2"7' - 5 1/4"A-5.106A-5.107203205101204003201(e) OPENING TO BE FILLED WITH (n) WINDOW OF SAME SIZE, SEE A-4.1(e) WINDOW OPENING TO BE FILLED, REPLACED WITH (n) WINDOW OF SAME SIZE, SEE A-4.10060910020604A-3.1IE-02.1IE-02.1A-3.13IE-03.14IE-03.25IE-03.36IE-03.4A-3.11IE-01.117R: 6-1/8"17T:11"NO WORKNO WORKNO WORKNO WORKNO WORK050404A-3.17IE-04.1A-5.108208A-5.1062092' - 6"1108060713141512162223PLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDSRevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:11 AMA-1.21/4" = 1'-0"1Proposed Floor 11/4" = 1'-0"2Proposed Floor 2Schneider Residence228 13th StreetSeal Beach, CA 90740Proposed PlansKEYNOTES001 (n)METAL ENTRY DOOR WITH SIDELIGHT002 (n)PLANTER, WOOD-LIKE TILE003 (n)POCKET DOOR004 (n)BARN DOOR005 (n)CABLE RAIL HANDRAIL +36", SEE DETAIL/A-5.1006 (n)CABLE RAIL GUARDRAIL +42", SEE DETAIL/A-5.1007 (e)COLUMN TO BE WRAPPED IN WOOD-LIKE TILE008 (e)STUCCO009 (n)WINDOW101 +36", 2" COUNTERTOP, PENTAL OR SIM.- QUARTZ102 BASE CABINETS (4" TOE KICK PROVIDED AT ALLINSTANCES)201 LOW FLUSH TOILET (MAX 1.28 GPF)203 WALK IN SHOWER, TEMPERED GLASS ENCLOSURE204 BATHROOM SINK205 FREESTANDING TUB207 CORNER SINK208 TILE @ WALL UP TO 72" AFF209 4" CURB @ SHOWER; SLOPE SHOWER PAN TO DRAIN1111
Level 10' -0"Level 28' -2"Roof18' -0"EXISITNG WINDOW BLOCKS TO BE REPLACED BY SAME SIZE (n) WINDOW 0403030304040400900900924' - 5"26' - 5"12'- 0" PROVIDED SETBACKALLEY15'- 0" ALLEY WIDTH100'- 0" PROPERTY LENGTH10'- 7" PROVIDED SETBACKALL (e) WINDOWS TO BE REPLACED WITH SAME SIZE WINDOW 03(e) WINDOWS TO BE REPLACED BY SAME SIZE (n) WINDOW 04Level 10' -0"Level 28' -2"Roof18' -0"A-5.101A-5.102A-5.103A-5.104A-5.1050202020020010070090083' - 1 1/4"23' - 3 3/4"26' - 5"3' - 0"3' - 0"37'- 6" PROPERTY WIDTHPLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDSRevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:17 AMA-2.11/4" = 1'-0"02E-021/4" = 1'-0"01E-01Schneider Residence228 13th StreetSeal Beach, CA 90740Exterior ElevationsKEYNOTES001 (n)METAL ENTRY DOOR WITH SIDELIGHT002 (n)PLANTER, WOOD-LIKE TILE003 (n)POCKET DOOR004 (n)BARN DOOR005 (n)CABLE RAIL HANDRAIL +36", SEE DETAIL/A-5.1006 (n)CABLE RAIL GUARDRAIL +42", SEE DETAIL/A-5.1007 (e)COLUMN TO BE WRAPPED IN WOOD-LIKE TILE008 (e)STUCCO009 (n)WINDOW101 +36", 2" COUNTERTOP, PENTAL OR SIM.- QUARTZ102 BASE CABINETS (4" TOE KICK PROVIDED AT ALLINSTANCES)201 LOW FLUSH TOILET (MAX 1.28 GPF)203 WALK IN SHOWER, TEMPERED GLASS ENCLOSURE204 BATHROOM SINK205 FREESTANDING TUB207 CORNER SINK208 TILE @ WALL UP TO 72" AFF209 4" CURB @ SHOWER; SLOPE SHOWER PAN TO DRAIN(e) WINDOW & BALCONY TO BE DEMOLISHED, WALL TO BE FILLED AND REPLACED BY THREE VERTICAL WINDOWS (SHOWN)1111
Level 10' -0"Level 28' -2"Roof18' -0"A-5.105A-5.104010523' - 3 3/4"3' - 1 1/4"26' - 5"12' - 0"100'- 0" PROPERTY LENGTH10'- 7" PROVIDED SETBACK15'- 0" ALLEY WIDTHALLEY4' - 8"(e) WINDOW OPENING TO BE FILLED(e) OPENING TO BE FILLED, REPLACED WITH NEW WINDOW 01Level 10' -0"Level 28' -2"Roof18' -0"3' - 0"3' - 0"37'- 6" PROPERTY WIDTH06(e) WINDOW OPENING TO BE FILLED AND REPLACED WITH NEW WINDOW 06PLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDSRevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:19 AMA-2.21/4" = 1'-0"04E-041/4" = 1'-0"03E-03Schneider Residence228 13th StreetSeal Beach, CA 90740Exterior ElevationsKEYNOTES001 (n)METAL ENTRY DOOR WITH SIDELIGHT002 (n)PLANTER, WOOD-LIKE TILE003 (n)POCKET DOOR004 (n)BARN DOOR005 (n)CABLE RAIL HANDRAIL +36", SEE DETAIL/A-5.1006 (n)CABLE RAIL GUARDRAIL +42", SEE DETAIL/A-5.1007 (e)COLUMN TO BE WRAPPED IN WOOD-LIKE TILE008 (e)STUCCO009 (n)WINDOW101 +36", 2" COUNTERTOP, PENTAL OR SIM.- QUARTZ102 BASE CABINETS (4" TOE KICK PROVIDED AT ALLINSTANCES)201 LOW FLUSH TOILET (MAX 1.28 GPF)203 WALK IN SHOWER, TEMPERED GLASS ENCLOSURE204 BATHROOM SINK205 FREESTANDING TUB207 CORNER SINK208 TILE @ WALL UP TO 72" AFF209 4" CURB @ SHOWER; SLOPE SHOWER PAN TO DRAIN111
05TT004A-5.1068' - 9 1/2"066' - 0"2041010030' - 10"0' - 8"2' - 0"1' - 0"4' - 0"7' - 8"2032042' - 0"1' - 0"3' - 0"101205042052037' - 2 1/4"009TPLPROPERTY LINE EXTERIOR ELEVATIONSETBACK LINE ELEVATION TAGINTERIOR CENTERLINEELEVATION MARKERKEYNOTESECTION MARKERW/ CUTLINE WINDOW TAGDETAIL MARKER DOOR TAGNEW WALLS TEMPERED GLASSWALLS TO BE DEMOLISHEDOPENINGS OF (e) WINDOWS TO BE DEMO'D/FILLED?A1011t1011A1011A1011A101TLEGENDGENERAL NOTESUNLESS OTHERWISE NOTED, ALL WALLS TO BE 2X6 ALL PLANTS, GRASS, AND TREES PLANTED ON SITE SHALL BE DROUGHT TOLERANT AND NON INVASIVEALL PLUMBING FIXTURES TO BE WATER-CONSERVING FIXTURESONLY (n) WINDOWS TAGGEDSLevel 10' -0"Level 28' -2"(e) FIREPLACERevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:21 AMA-3.11/2" = 1'-0"1IE-01.11/2" = 1'-0"IE-02.1IE-02.11/2" = 1'-0"3IE-03.11/2" = 1'-0"4IE-03.21/2" = 1'-0"5IE-03.31/2" = 1'-0"6IE-03.4Schneider Residence228 13th StreetSeal Beach, CA 90740Interior Elevations1/2" = 1'-0"7IE-04.1KEYNOTES001 (n)METAL ENTRY DOOR WITH SIDELIGHT002 (n)PLANTER, WOOD-LIKE TILE003 (n)POCKET DOOR004 (n)BARN DOOR005 (n)CABLE RAIL HANDRAIL +36", SEE DETAIL/A-5.1006 (n)CABLE RAIL GUARDRAIL +42", SEE DETAIL/A-5.1007 (e)COLUMN TO BE WRAPPED IN WOOD-LIKE TILE008 (e)STUCCO009 (n)WINDOW101 +36", 2" COUNTERTOP, PENTAL OR SIM.- QUARTZ102 BASE CABINETS (4" TOE KICK PROVIDED AT ALLINSTANCES)201 LOW FLUSH TOILET (MAX 1.28 GPF)203 WALK IN SHOWER, TEMPERED GLASS ENCLOSURE204 BATHROOM SINK205 FREESTANDING TUB207 CORNER SINK208 TILE @ WALL UP TO 72" AFF209 4" CURB @ SHOWER; SLOPE SHOWER PAN TO DRAIN
Revisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:21 AMA-4.1Window ScheduleMark Width Height Decription01 5' - 0" 2' - 0" (n) CLERESTORY FG02 3' - 0" 3' - 0" (n) FG, TEMPERED03 3' - 4" 1' - 10" (n) FG04 3' - 11" 4' - 7 1/2" (n) SL05 6' - 0" 2' - 0" (n) CLERESTORY, SL06 3' - 9" 3' - 9 1/2" (n) SLDoor ScheduleMark Width Height DESCRIPTION01 3' - 3 3/4" 7' - 0" (n)METAL ENTRY DOOR WITH SIDELIGHT02 2' - 6" 7' - 0" (n) SOLID CORE, PAINT GRADE03 2' - 6" 7' - 0" (e) SOLID CORE, PAINT GRADE04 2' - 8" 7' - 0" (e) SOLID CORE, PAINT GRADE05 2' - 8" 7' - 0" (e) SOLID CORE, PAINT GRADE06 2' - 8" 7' - 0" (e) SOLID CORE, PAINT GRADE07 2' - 6" 7' - 0" (e) SOLID CORE, PAINT GRADE08 2' - 10" 7' - 0" (e) SOLID CORE, PAINT GRADE09 3' - 0" 8' - 0" (n) SLIDING BARN DOOR WITH VALENCE, SEE DETAILS10 3' - 0" 8' - 0" (n) SLIDING BARN DOOR WITH VALENCE, SEE DETAILS11 2' - 4" 7' - 0" (n) SLIDING POCKET DOOR12 1' - 6" 7' - 0" (n) FAU CLOSET DOOR, SOLD CORE, PAINT GRADE13 2' - 8" 7' - 0" (e) SOLID CORE, PAINT GRADE14 2' - 6" 7' - 0" (e) SOLID CORE, PAINT GRADE15 2' - 8" 7' - 0" (e) SOLID CORE, PAINT GRADE16 4' - 9" 8' - 0" (e) FRENCH DOUBLE DOORS17 4' - 9" 8' - 0" (e) FRENCH DOUBLE GLASS DOORS18 5' - 9" 7' - 0" (e) SLIDING GLASS DOOR19 2' - 6" 7' - 0" (e) EXTERIOR DOOR TO FURNACE20 4' - 9" 8' - 0" (e) FRENCH DOUBLE DOORS21 15' - 4" 8' - 1" (e) SECTIONAL GARAGE DOOR22 2' - 10" 7' - 0" (e) SINGLE GLASS PANEL DOOR23 4' - 9" 8' - 0" (e) FRENCH DOUBLE DOORSFG= FIXED GLASSSL= SLIDERNOTE: ONLY NEW WINDOWS INCLUDED IN WINDOW SCHEDULE
011" = 1'-0"PLANTERFIBERGLASS MEMBRANE O/ HOT MOPFRAMING (PER STRUCTURAL)CANT STRIPSTAINLESS STEEL POT INSERTMETAL CAP NO PENETRATION AT TOPDRAINGALVANIZED DIAMOND MESH LATHINSULATED SHEATHINGBUILDING PAPERNOTE:PROVIDE 2 LAYERS OF GRADE D BLDG. PAPER OVER ALL WOOD BASE SHEATHING.WOOD LIKE TILE023" = 1'-0"DOOR THRESHOLDDOOR PANEL PER SCHEDULE.VERIFY W/MANUFACTURERAPPV'D THRESHOLD PROVIDEBITUMINOUS COATING ON SILLFOR SEPERATION OF ALUM. &CONC. OR OTHER APPV'DMEASURE TO ISOLATE/PROTECTPER CBC.SEC.2804 (C)CONCRETE SLABAPPV'D WEATHER STRIPPINGSEALANT<1"FINISHED FLOOR033" = 1'-0"DOOR HEAD7/8" EXT. STUCCOo/ BLDG. PAPERCONTINUOUS SEALANTDOOR PANEL PER SCHEDULE .VERIFY W/MANUFACTURER5/8" TYPE X GYP. BD. @WALLS <5 FT. TO PROP. LINEHEADERMOIST STOPVERIFY DETAIL WITH DOOR MANUFACTURER043" = 1'-0"WINDOW SILL5/8" TYPE X GYP. BD. @WALLS <5 FT. TO PROP. LINE2X STUDS @ 16" O.C.7/8" EXT. STUCCOo/BLDG. PAPER o/LAYER OF BITUTHENECAULK @ JOINT &BEHIND FRAMEINSULATION PER TITLE 24WINDOW FRAME PER SCHEDULE.VERIFY W/MANUFACTURERBITUTHENE TO EXTEND O/ SILL2X PRESSURETREATED SILL PLATEVERIFY DETAIL WITH WINDOW MANUFACTURER053" = 1'-0"WINDOW HEAD5/8" TYPE X GYP. BD. @WALLS <5 FT. TO PROP. LINE2X STUDS @ 16" O.C.INSULATION PER TITLE 24WINDOW FRAME PER SCHEDULE.VERIFY W/MANUFACTURERCONTINUOUS SEALANT7/8" EXT. STUCCOo/BLDG. PAPER o/LAYER OF BITUTHENEHEADER12" LAPVERIFY DETAIL WITH WINDOW MANUFACTURERNOTE:ALL ATTACHMENTS ANDHARDARE PER MANUF.SPECS.063" = 1'-0"BARN DOORSTUD WALLWOOD VALANCEATTACH PER MANUF.METAL TRACK BRACKET,ATTACH TO EXISTINGSTUD WALLMETAL TRACKROLLERDOOR HANGER/BRACKETS1-1/2" THICK WOODBARN DOORSTUD WALLBARN DOORMETAL WRAP ATBOTTOM OF DOORMETAL TRACKATTACH TO FLOOR073" = 1'-0"NICHEMETAL LATH O/ BLDG. PAPER2x BLOCKINGMORTAR BEDTILE W/ SEALED GROUT JOINTS3" DEPTHBITUTHENE @ CORNERS AND EDGE081" = 1'-0"INTERIOR GUARDRAIL/HANDRAILSTEEL POSTHANDRAIL 1-1/2"ØSTEEL TUBING<4" 42" ABV. FIN. FLR. @GUARDRAILNOTE:NO OPENING TO ALLOW A 4" SPHERE TOPASS THROUGH TUBING.4"Ø091" = 1'-0"INTERIOR STAIRS5/8" TYPE X GYP. BD.ONENCLOSED SIDE (CLOSETWALLS & CEILINGS)1" NOSING TYP.3/4" PLYWOODO/ STRINGERS3/4" PLYWOODO/ STRINGERSFINISHED FLOORINGHARDWOODSTEEL STRINGERHANDRAIL 1-1/2""ØSTEEL TUBINGSTEEL POST4" MAX.10" MIN. RUN7-3/4"34"-38" RAIL HT. ABV. STAIR NOSINGNOTE:NO OPENING TO ALLOW A 4" SPHERE TOPASS THRU TUBING.6" SPHERE ALLOWABLE @ TRIANGULAROPENINGS BY TREAD & RISER6"Ø4"ØMAX. RISERevisions: By:909 Electric Ave. Studio 207Seal Beach, CA 90740(714) 846-0177www.otisarchitecture.comOtis Architecture Inc.Date:Project Architect:Drawn:Sheet Number:K. OtisC. Ivey15/8/19 PLAN CHECKCI5/9/2019 8:22:22 AMA-5.1Schneider Residence228 13th StreetSeal Beach, CA 90740Details
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
THRU:Steve Fowler, Interim Director of Community Development
FROM:Marco Cuevas Jr., Assistant Planner
SUBJECT:Request for MINOR USE PERMIT (MUP 19-4) to allow an interior and
exterior remodel to convert an existing first floor family room and
kitchen to a master bedroom, and convert the existing second floor
master bedroom and bathroom area into a kitchen, living and dining
room at a property that is nonconforming due to setbacks in Surfside
Colony in the Residential Low Density (RLD-9) zoning area.
LOCATION:43 B Surfside Avenue
APPLICANT:FARR Capital LLC/Kevin Chinnock
RECOMMENDATION:After conducting the Public Hearing, staff recommends that the
Planning Commission adopt Resolution No. 19-11, APPROVING
Minor Use Permit 19-4 with Conditions.
GENERAL PLAN
DESIGNATION:
RESIDENTIAL LOW DENSITY
ZONE:RLD-9 (RESIDENTIAL LOW DENSITY)
SITE DESCRIPTION:ASSESSOR’S PARCEL NUMBER: 178-481-18
LOT AREA: 1,767 SQ. FT.
GROSS FLOOR AREA: 2,394 SQ. FT.
SURROUNDING PROPERTIES:
NORTH: RESIDENTIAL HIGH DENSITY (RHD-20)
SOUTH: BEACH (BEA)
EAST: RESIDENTIAL LOW DENSITY (RLD-9)
WEST: RESIDENTIAL LOW DENSITY (RLD-9)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of alterations to the interior and exterior of an
existing residential property where only minor modifications are required for the renovation.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on July 25,
2019 and mailed to property owners and occupants within a 300’ radius of the subject property
on July 25, 2019, with affidavits of publishing and mailing on file.
VICINITY MAP: AERIAL MAP:
ANALYSIS
The applicant, Kevin Chinnock/Farr Capital LLC, filed an application with the Community
Development Department for Minor Use Permit 19-4 requesting approval of Minor Use Permit
(MUP) 19-4 to allow remodeling of the interior and exterior of the property. The subject site is a
1,767 square foot parcel located on the north side portion of Surfside Avenue within the Surfside
Colony, a gated private residential community. The lot is currently developed with a three-story
residence. The subject site is in the Residential Low Density (RLD-9) zoning area and is
surrounded by residential uses.
The subject property is nonconforming due to interior side yard setbacks. According to Table
11.2.05.015 A.1 of the Seal Beach Municipal Code, Surfside Yard Requirements, interior lot
properties are required to maintain a side yard setback that is 10% of the lot width, or a 3 foot
minimum. The subject property measures approximately 25 feet wide by 70.19 feet deep. Based
on these dimensions, the development standard requires a side yard setback of 3 feet.
The proposed improvements to the interior of the residence consist of the following
modifications: a first floor remodel of the existing family room and kitchen into a master bedroom
with bathroom; a second floor remodel to convert the existing master bedroom and bathroom
area into a kitchen, living and dining room area; and lastly, a third floor remodel which would
retain the existing two bedrooms, upgrade the existing bathroom, create a closet for bedroom
#2 and create a walk-in closet for bedroom #3. No additional habitable square footage is
proposed.
The proposed improvements to the exterior of the residence include removal of the existing
wood siding from the south side of the residence and frame window on the exterior part of the
wall and re-stucco the residence to provide a smooth stuccoed finish. Finally, the mansard style
roof surrounding the residence will be removed, but the existing parapet will be retained and
stuccoed to match the new smooth stucco finish. The proposed improvements will not result in
additional lot coverage as the areas of improvement are at present covered by the existing
structure.
The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor improvements which
involve the removal or alteration to less than 25% of a structure’s interior walls, provided the
bedroom/bathroom ratio does not exceed one and one-half bathrooms for each bedroom. The
subject building is proposed to have the same amount of bedrooms and add one and one-half
bathrooms for a total of 3 bedrooms and 3 ½ bathrooms, which conforms to the provisions of
SBMC § 11.4.40.015.B. The alterations proposed on the subject site are consistent with the
provisions of the code and similar to other improvements in the area. The proposal will not
intensify the nonconforming setback. The resolution conditions the approval to maintain
continuing compliance with those requirements.
CONCLUSION
After concluding the public hearing and receiving public testimony, staff recommends that the
Planning Commission adopt attached Resolution No. 19-11 approving MUP 19-4 to allow the
interior and exterior remodel at a nonconforming property.
Prepared by:
Marco Cuevas Steve Fowler
Marco Cuevas Jr. Steve Fowler
Assistant Planner Interim Director of Community Development
Attachments:
1. Resolution No. 19-11 – A Resolution of the Planning Commission of the City of Seal
Beach Approving Minor Use Permit 19-4 to allow the interior and exterior remodel of a
nonconforming property at 43 B Surfside Avenue in the Residential High Density (RLD-9)
zoning area.
2. Site Plan and Elevations
RESOLUTION NO. 19-11
A RESOLUTION OF THE PLANNING COMMISSION OF THE
CITY OF SEAL BEACH APPROVING MINOR USE PERMIT 19-4
TO ALLOW AN INTERIOR AND EXTERIOR REMODEL TO
CONVERT AN EXISTING FIRST FLOOR FAMILY ROOM AND
KITCHEN TO A MASTER BEDROOM, AND CONVERT THE
EXISTING SECOND FLOOR MASTER BEDROOM AND
BATHROOM AREA INTO A KITCHEN, LIVING AND DINING
ROOM AT A NONCONFORMING PROPERTY THAT IS
NONCONFORMING DUE TO SETBACKS IN THE RESIDENTIAL
LOW DENSITY (RLD-9) ZONING AREA.
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES HEREBY
RESOLVE:
Section 1. Kevin Chinnock/Farr Capital LLC, (“the applicant and owners”)
submitted an application to the Community Development Department for Minor Use Permit
19-4. The proposed project includes the alteration of less than 25% of interior walls to allow
the remodel of the interior of an existing single family home by (1) altering walls to remodel
the first floor by eliminating the family room and kitchen and adding a master bedroom with
bathroom; (2) remodeling the second floor by eliminating the existing master bedroom and
bathroom area and adding a kitchen, living and dining room area; (3) remodeling the third
floor by upgrading the existing bathroom, retaining the existing two bedrooms, adding a new
closet for bedroom #2 and a new walk-in closet for bedroom #3, and (4) by removing the
existing mansard style roof, and re-stuccoing the existing parapet wall to match the new
smooth stucco finish, on a property which is nonconforming due to setbacks, and located in
the Residential Low Density (RLD-9) zoning area.
Section 2. This project is determined to be a Class 1 (Existing Facilities)
Categorical Exemption pursuant to Section 15301 of the Guidelines for the California
Environmental Quality Act (Public Resources Code Section 21000 et seq.) for the permitting
of alterations to the interior and exterior of an existing residential property where only minor
modifications are required for the renovation.
Section 3. A duly noticed public meeting was held before the Planning
Commission on August 5, 2019 to consider Minor Use Permit 19-4. At the public meeting,
the Planning Commission received into the record all evidence and testimony provided on
this matter. The record of the hearing indicates the following:
A. The applicant submitted an application to the Community Development
Department for Minor Use Permit 19-4 for a proposed project at 43 B Surfside Avenue, Seal
Beach, California.
B. The subject property is rectangular in shape with a lot area of
approximately 2,394 square feet. The subject property has a lot width of 25 feet with a lot
depth of 70.19 feet. The site is surrounded by residential uses on all sides.
C. The subject property is currently developed with a single residential unit.
Based on the setback, the subject property is considered nonconforming. The proposed
Resolution 19-11
43 B Surfside Avenue
improvements will not expand any existing nonconformity because no new bedrooms or
additional habitable square footage is proposed.
D. The Seal Beach Municipal Code (SBMC § 11.4.40.015.B) allows minor
improvements which involve the removal or alteration to less than 25% of a structure’s
interior walls, provided the bedroom/bathroom ratio does not exceed one and one-half
bathrooms for each bedroom.
Section 4. Based upon the facts contained in the record, including those
stated in the preceding Section of this resolution and pursuant to Chapter 11.5.20 of the Seal
Beach Municipal Code, the Planning Commission makes the following findings:
A. The proposed minor improvements are consistent with the General Plan.
The General Plan specifies that redevelopment in the Surfside Colony is to be compatible
with the physical characteristics of its site, surrounding land uses, and available
infrastructure. The proposed minor improvements will not change the character of the
residence and will be consistent with other properties.
B. The proposed use is allowed within the applicable zoning district with
Minor Use Permit approval and will comply with all other applicable provisions of the
Municipal Code. The subject site is located within the Surfside RLD-9 zone, an area where
the Seal Beach Municipal Code (Section 11.4.40.015.B) allows minor improvements which
involve interior and exterior alterations.
C. The proposed use, as conditioned below, will be located on a site that is
physically adequate for the type, density, and intensity of use being proposed, including
provision of services, and the absence of physical constraints. The subject site is currently
developed with a single family residence with a detached garage and is considered
nonconforming due to setbacks. The alteration of less than 25% of interior walls and
modification of the roof will not add habitable space and will maintain development standards
applicable to the RLD-9 zone.
D. The location, size, design, and operating characteristics of the proposed
use, as conditioned below, will be compatible with and will not adversely affect uses and
properties in the surrounding neighborhood. The subject site is located within the Surfside
RLD-9 zone, which consists of properties developed as single family residences. Roof decks
and covered roof access structures are common non-habitable architectural features
associated in this zoning district. The property is proposed to be used as a single family
residence which is consistent with the surrounding area.
E. The establishment, maintenance, and operation of the proposed use will
not be detrimental to the health, safety, or welfare of persons residing or working in the
vicinity. The alteration of less than 25% of interior walls will not increase bedrooms, exceed
the bedroom/bathroom ratio authorized under the development standards, or intensify use on
the property. The subject site will continue to operate as a residential property, which is
consistent with the uses in the surrounding neighborhood.
Resolution 19-11
43 B Surfside Avenue
Section 5.Based on the foregoing, the Planning Commission hereby
approves Minor Use Permit 19-4 for alteration of less than 25% of interior walls in order to
remodel the first floor family room and kitchen into a master bedroom with bathroom; the
second floor master bedroom and bathroom into a kitchen, living and dining room area; and
to remodel the third floor by reconfiguring the existing bathroom, by creating a closet for
bedroom #2 and a walk-in closet for bedroom #3, and by removing the mansard style roof but
re-stuccoing the existing parapet to match the new smooth stucco finish, for the property
located in the Surfside Colony in the Residential Low Density RLD (9) zoning area, subject to
the following conditions:
1. Minor Use Permit 19-4 is approved for the alteration of less than 25% of interior walls
in order to remodel the first floor family room and kitchen into a master bedroom with
bathroom; the second floor master bedroom and bathroom into a kitchen, living and
dining room area; and by reconfiguring the existing bathroom on the third floor, by
creating a closet for bedroom #2 and a walk-in closet for bedroom #3; and by
removing the mansard style roof and re-stuccoing the existing parapet to match the
new smooth stucco finish, at a nonconforming property located at 43 B Surfside
Avenue.
2. All plan checks and construction shall be in substantial compliance with the plans
approved through Minor Use Permit 19-4. All new construction shall comply with all
applicable state and local codes.
3. The applicant is required to obtain all Building and Safety permits prior to construction
or demolition.
4. All materials, color, and finishes of the wall finish will be consistent with existing roof
pitches and exterior finishes of the residential dwelling.
5. Applicant shall obtain California Coastal Commission approval prior to building permit
issuance.
6.This Minor Use Permit shall not become effective for any purpose unless an
“Acceptance of Conditions” form has been signed, notarized, and returned to the
Community Development Department; and until the ten (10) day appeal period has
elapsed.
7. The applicant shall indemnify, defend and hold harmless the City, its officers, agents
and employees (collectively “the City” hereinafter) from any and all claims and losses
whatsoever occurring or resulting to any and all persons, firms, or corporations
furnishing or supplying work, services, materials, or supplies in connection with the
performance of the use permitted hereby or the exercise of the rights granted herein,
and any and all claims, lawsuits or actions arising from the granting of or the exercise
of the rights permitted by this Minor Use Permit, and from any and all claims and
losses occurring or resulting to any person, firm, corporation or property for damage,
injury or death arising out of or connected with the performance of the use permitted
hereby. Applicant’s obligation to indemnify, defend and hold harmless the City as
stated herein shall include, but not be limited to, paying all fees and costs incurred by
Resolution 19-11
43 B Surfside Avenue
legal counsel of the City’s choice in representing the City in connection with any such
claims, losses, lawsuits or actions, expert witness fees, and any award of damages,
judgments, verdicts, court costs or attorneys’ fees in any such lawsuit or action.
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning Commission at a
meeting thereof held on August 5, 2019, by the following vote:
AYES: Commissioners
NOES: Commissioners
ABSENT: Commissioners
ABSTAIN: Commissioners
Patricia Campbell
Chairperson
ATTEST:
__________________________
Steven Fowler
Planning Commission Secretary
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
FROM:Steve Fowler, Interim Director of Community Development
SUBJECT:Request for a CONDITIONAL USE PERMIT CUP 19-6 to allow the
addition of 751 square feet and the interior remodel of an existing one-
story single-family residence that is nonconforming due to garage
setbacks withn the Residential High Density (RHD-20) zoning area.
LOCATION:218 13th Street
APPLICANT:Steven Sennikoff
RECOMMENDATION:After reviewing the application, staff recommends that the Planning
Commission adopt Resolution No. 19-14, APPROVING Conditional
Use Permit 19-6 with conditions
GENERAL PLAN
DESIGNATION:
RESIDENTIAL HIGH DENSITY
ZONE:RHD-20 (RESIDENTIAL HIGH DENSITY
SITE DESCRIPTION:Assessor’s Parcel Map Number: 043-134-20
Lot Area: 3,750 square feet
Building Area: 1,866 square feet
Surrounding Properties:
North: Residential High Density (RHD-20)
South: Residential High Density (RHD-20)
East: Residential High Density (RHD-20)
West: Residential High Density (RHD-20)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of an addition that is not over 10,000 square feet
and remodel at an existing one-story single-family residence that is in an area where all public
services and facilities are available.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on July 25,
2019 and mailed to property owners and occupants within a 500’ radius of the subject property
on July 25, 2019, with affidavits of publishing and mailing on file.
VICINITY MAP: AERIAL MAP:
ANALYSIS
Steven Sennikoff (“the applicant”) on behalf of Elizabeth Smith (“the owner”), filed an
application for Conditional Use Permit 19-6 to allow a 751 square foot addition to an
existing 721 square foot single-family residence with a two-car-garage which is nonconforming
due to setbacks. The subject site is a rectangular shaped 3,750 sq. ft. parcel located on
the east side of 13th Street between Electric Avenue and Landing Avenue in The Old
Town area within the RHD-20 (Residential High Density) zoning area. The parcel is
currently developed with a one-story single family residence with two bedrooms and one
bath, and a detached two-car garage. The subject site is surrounded by residential uses
on all sides. The applicant is proposing an addition connecting the existing residence
and the garage along with two other additions and the addition of a front porch. The
addition that connects to the existing residence and the garage will not change the
square footage of the existing garage.
According the Seal Beach Municipal Code (SBMC §11.6.05.010) the front property line on a
corner lot is the line adjacent to the street with the shortest frontage. Therefore, the front
property line for the subject property is Coastline Drive.
The subject property is nonconforming due to the interior side yard setbacks of the garage.
According to Table 11.2.05.015 of the Seal Beach Municipal Code, interior side yard setbacks
on properties in the in the RHD-20 zoning area are required to be 10 percent of the property
width or a minimum 3 feet. The width of the property is 37 feet 6 inches so the interior side yard
setback on the south side of the garage is required to be 3 feet 9 inches, but is only 3 feet 4
inches.
The applicant is proposing to add approximately 751 square feet of total habitable space as a
one-story addition and a front porch to the existing single-story residence. With the addition, the
applicant will add a master bedroom and master bathroom to the existing 2-bedroom one-
bathroom residence. The proposed addition will result in additional lot coverage. The proposed
lot coverage will increase to approximately 50%, which is less than the maximum 75% lot
coverage that is permitted in the RHD-20 zone.
The Seal Beach Municipal Code (SBMC § 11.4.40.020.) allows improvements which involve the
alteration or addition to residences that are nonconforming due to setbacks. The addition is to
add habitable square footage to the first floor of a residential structure that itself conforms to all
the requirements of the Municipal Code. The Conditional Use Permit is required because the
south side of the garage does not meet the interior side yard setback requirement. The addition
will not intensify the nonconforming side yard setback of the garage, as the addition along the
south property line will maintain a minimum 4-foot setback. The proposed addition is consistent
with other residential properties in the houses in the zone.
CONCLUSION
After conducting the public hearing and receiving testimony, staff recommends that the Planning
Commission adopt the attached Resolution No. 19-14 approving Conditional Use Permit CUP 19-6 to
allow the addition of 751 square feet including the addition of a front porch and the interior remodel of an
existing one-story single-family residence on an existing nonconforming property at 218 13th Street.
Prepared by:
Steve Fowler
Steve Fowler
Interim Director of Community Development
Attachments:
1. Resolution No. 19-14 – A Resolution of the Planning Commission of the City of Seal
Beach, Approving Conditional Use Permit 19-6 allow the addition of 751 square feet and
the interior remodel of an existing one-story single-family residence on a nonconforming
site at 218 13th Street in the Residential High Density (RHD-20) Zoning Area.
2. Project architectural plans.
Page 1 of 4
RESOLUTION NO. 19-14
A RESOLUTION OF THE PLANNING COMMISSION OF
THE CITY OF SEAL BEACH APPROVING CONDITIONAL
USE PERMIT 19-6 TO ALLOW THE ADDITION OF
APPROXIMATELY 751 SQ. FT. AND THE INTERIOR
REMODEL OF AN EXISTING ONE-STORY RESIDENCE
ON A PROPERTY THAT IS NONCONFORMING DUE TO
SETBACKS LOCATED AT 218 13TH STREET IN THE
RESIDENTIAL HIGH DENSITY (RHD-20) ZONING AREA.
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES HEREBY
RESOLVE:
Section 1. Steven Sennikoff (“the applicant”), on behalf of property
owner Elizabeth Smith, (“the owner”) submitted an application to the Community
Development Department for Conditional Use Permit 19-6. The proposed project
includes the addition of approximately 751 square feet and the interior remodel of an
existing one-story single-family residence which is nonconforming due to setbacks in
the Residential High Density (RHD-20) zoning area.
Section 2. This project is determined to be a Class 1 (Existing
Facilities) Categorical Exemption pursuant to Section 15301(e)(2) of the Guidelines for
the California Environmental Quality Act (Public Resources Code Section 21000 et
seq.) for the permitting of an addition that is under 10,000 sq. ft. and all public services
and facilities are available to allow maximum development and the area is not
environmentally sensitive.
Section 3. A duly noticed public hearing was held before the Planning
Commission on August 5, 2019 to consider Conditional Use Permit 19-6. At the public
hearing, the Planning Commission received into the record all evidence and testimony
provided on this matter. The record of the hearing indicates the following:
A. The subject property is rectangular in shape with a lot area of
approximately 3,750 square feet. The property is approximately 37 feet 6 inches wide
by 100 feet deep. The site is surrounded by residential uses on all sides.
B. The subject property is proposing to add 751 square feet and
remodel the existing one-story single-family residence containing two bedrooms and
one bathroom, and with a detached two car garage at the rear. Based on the existing
setback conditions, the subject property is considered nonconforming because the
garage does not maintain the required south side yard setback. The proposed
improvements will not expand any existing nonconformity. The proposed addition will
comply with all required setbacks.
C. The Seal Beach Municipal Code (SBMC § 11.4.40.020) allows
improvements, which involve the alteration or addition to residences that are
nonconforming due to setbacks. The addition is to add approximately 751 square feet to
Resolution 19-14
218 13th Street
Page 2 of 4
the one-story residential structure that conforms to all the requirements of the Municipal
Code. The addition will not intensify the nonconforming setback as the addition is
proposed on the residential structure that meets all the requirements of the Municipal
Code. Part of the addition will attach the residence to the existing garage but will be
constructed to meet all required setbacks.
D. The applicant is proposing to add approximately 751 square feet to
the one-story residence. The proposed addition will add a master bedroom and
bathroom to the existing two-bedroom one-bathroom residence, and also add a front
porch. The proposed addition will increase lot coverage to approximately 50%, which is
less than the maximum 75% lot coverage that is permitted in the RHD-20 zone.
Section 4. Based upon the facts contained in the record, including
those stated in the preceding Section of this resolution and pursuant to Chapter 11.5.20
of the Seal Beach Municipal Code, the Planning Commission makes the following
findings:
A. The proposed addition and remodel are consistent with the General
Plan which encourages architectural diversity in the Old Town area (Planning Area 1)
while ensuring compatibility between residential and commercial uses. The General
Plan also recognizes existing nonconforming land uses and permits minor alterations.
The proposed addition to the residence will allow for addition of a master bedroom,
master bathroom and front porch, but will not expand any nonconformity and will be
consistent with other surrounding properties. The property is nonconforming because
the detached garage does not meet the required interior side yard setback along the
south property line.
B. The proposed use is allowed within the applicable zoning district
with Conditional Use Permit approval and will comply with all other applicable provisions
of the Municipal Code. The subject site is located within the Old Town RHD-20 zone, an
area where the Seal Beach Municipal Code (Section 11.4.40.020) allows additions and
improvements such as the alteration or addition of habitable square footage to
nonconforming properties with approval of a Conditional Use Permit.
C. The proposed use, as conditioned below, will be located on a site
that is physically adequate for the type, density, and intensity of use being proposed,
including provision of services, and the absence of physical constraints. The subject site
is currently occupied with a one-story single-family residence and is considered
nonconforming due to setbacks only. The addition to the residence will maintain
development standards applicable to the RHD-20 zone.
D. The location, size, design, and operating characteristics of the
proposed use, as conditioned below, will be compatible with and will not adversely
affect uses and properties in the surrounding neighborhood. The subject site is located
within the RHD-20 zone, which consists of properties developed as single family and
multi-family residences. The improvement will add approximately 751 square feet of
Resolution 19-14
218 13th Street
Page 3 of 4
habitable space, and will remain similar to surrounding residential uses throughout the
RHD-20 zoned area.
E. The establishment, maintenance, and operation of the proposed
use will not be detrimental to the health, safety, or welfare of persons residing or
working in the vicinity. The addition to the residence will increase the existing lot
coverage to approximately 50 percent. The lot coverage on the subject site will continue
to be under the maximum 75 percent lot coverage permitted in the RHD-20 zone. The
subject site will continue to operate as a residential property, which is consistent with
the uses in the surrounding neighborhood.
Section 5. Based on the foregoing, the Planning Commission hereby
approves Conditional Use Permit 19-6 for the addition of approximately 751 square feet
and the interior remodel of an existing one-story single-family residence which is a
nonconforming property subject to the following conditions:
1. Conditional Use Permit 19-6 is approved for the addition of approximately 751
square feet and the interior remodel of an existing one-story single-family
residence which is nonconforming due to setbacks, on a property located at 218
13th Street.
2. All plan check and future construction shall be in substantial compliance with the
plans approved through Conditional Use Permit 19-6. All new construction shall
comply with all applicable state and local codes.
3. The applicant is required to obtain all Building and Safety permits prior to
construction or demolition.
4. All materials, color, wall finishes and roof material must be consistent with
existing material and exterior finishes of the residential dwelling.
6. This Conditional Use Permit shall not become effective for any purpose unless
an “Acceptance of Conditions” form has been signed, notarized, and returned to
the Community Development Department; and until the ten (10) day appeal
period has elapsed.
7. The applicant shall indemnify, defend and hold harmless the City, its officers,
agents and employees (collectively “the City” hereinafter) from any and all claims
and losses whatsoever occurring or resulting to any and all persons, firms, or
corporations furnishing or supplying work, services, materials, or supplies in
connection with the performance of the use permitted hereby or the exercise of
the rights granted herein, and any and all claims, lawsuits or actions arising from
the granting of or the exercise of the rights permitted by this Conditional Use
Permit, and from any and all claims and losses occurring or resulting to any
person, firm, corporation or property for damage, injury or death arising out of or
connected with the performance of the use permitted hereby. Applicant’s
obligation to indemnify, defend and hold harmless the City as stated herein shall
include, but not be limited to, paying all fees and costs incurred by legal counsel
Resolution 19-14
218 13th Street
Page 4 of 4
of the City’s choice in representing the City in connection with any such claims,
losses, lawsuits or actions, expert witness fees, and any award of damages,
judgments, verdicts, court costs or attorneys’ fees in any such lawsuit or action.
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning
Commission at a meeting thereof held on August 5, 2019, by the following vote:
AYES: Commissioners
NOES: Commissioners
ABSENT: Commissioners
ABSTAIN: Commissioners
Patricia Campbell
Chairperson
ATTEST:
__________________________
Steve Fowler
Planning Commission Secretary
PLANNING COMMISSION
STAFF REPORT
DATE:August 5, 2019
TO:Planning Commission
FROM:Steve Fowler, Interim Director of Community Development
SUBJECT:Request for a CONDITIONAL USE PERMIT CUP 19-5 to allow an
interior remodel to an existing banquet facility to reduce the size of an
existing bar and create an additional bar within the facility at the Old
Ranch Country Club in the Recreation/Golf (RG) Zone.
LOCATION:3901 Lampson Avenue
APPLICANT:Frank Herrera
RECOMMENDATION:After reviewing the application, staff recommends that the Planning
Commission adopt Resolution No. 19-13, APPROVING Conditional
Use Permit 19-5 with conditions
GENERAL PLAN
DESIGNATION:
OPEN SPACE - GOLF
ZONE:RG ( RECREATION/ GOLF)
SITE DESCRIPTION:Assessor’s Parcel Map Numbers: 130-012-54, 55, 56, 58
Lot Area: 154.19 acres
Building Area: 55,520 square feet
Surrounding Properties:
North: General Commercial (GC), and Los Alamitos Joint Forces
Training Base
South: Military (MIL) and San Diego Freeway I-405
East: Residential Low Density (RLD-9), Residential Medium Density
(RMD-18) and General Commercial (GC)
West: General Commercial (GC)
ENVIRONMENTAL ASSESSMENT
This project is determined to be a Class 1 (Existing Facility) Categorical Exemption pursuant to
Section 15301 of the Guidelines for the California Environmental Quality Act (Public Resources
Code Section 21000 et seq.) for the permitting of an interior remodel at an existing banquet
facility where only minor modifications are required for the renovation.
LEGAL NOTIFICATION
The legal notice of this hearing was published in the Seal Beach Sun Newspaper on July 25,
2019 and mailed to property owners and occupants within a 500’ radius of the subject property
on July 25, 2019, with affidavits of publishing and mailing on file.
VICINITY MAP: AERIAL MAP:
BACKGROUND
The subject site has operated as a golf course and driving range since 1967. The City has
granted the following discretionary approvals at this location: Plan review 70-22 for the addition
to the clubhouse building on August 4 1971; Conditional Use Permit CUP 92-14 for the approval
of an on-sale general license for the Old Ranch Country Club on October 21, 1992; Minor Plan
Review MPR 01-5 for the use of a temporary tent structure for temporary golf cart battery
charging and storage during a remodel and expansion of the existing structure on April 18, 2001;
and Conditional Use Permit CUP 07-16 for the addition of a 3,400 square foot banquet room,
200 square foot bridal suite, 3,500 square foot owner’s suite and an outdoor courtyard including
a swimming pool and spa on January 9, 2008.
ANALYSIS
Frank Herrera (“the applicant”) on behalf of Old Ranch Country Club (“the owner”), filed an
application for Conditional Use Permit 19-5 to allow an interior remodel to an existing banquet
facility to reduce the size of an existing bar and create an additional bar within the facility. The
subject site includes four irregularly shaped parcels totaling 154.19 acres located on the north
side of Lampson Avenue east of Seal Beach Boulevard within the RG (Recreation/ Golf) zoning
area. The parcel is currently developed with a golf course, driving range, pro-retail shop and
country club with banquette facility. The subject site is surrounded by residential uses on the
east and west sides, commercial on the north, east and west, the Los Alamitos Joint Forces
Training Base to the north and the I-405 freeway to the south.
According the Seal Beach Municipal Code (SBMC §11.5.20.025) Conditions of Approval, the
applicant is proposing a substantial change to the areas where alcohol is served by reducing the
size of one bar and creating a larger bar than the existing bar in another room in the facility. The
Planning Department is required to ensure that the proposal conforms in all significant respects
with the general Plan and any other applicable plans or policies adopted by the City Council.
The site currently has a Type 57 (On-Sale service of general alcohol to members of a private
club) Alcohol Beverage Control license. The hours of operation of the country club and golf
course are 6 AM to 2 AM 7 days a week; and the hours that alcohol can be served will continue
to be from 10 AM to 2 AM 7 days a week as originally approved in CUP 92-14.
The applicant is proposing to remodel the interior of the facility to provide a variety of options for
the customers to enjoy. The new floor plans include creation of fine dining, family dining and
private dining areas along with a children’s play room. These areas are adjacent to each other
but delineated. The plans also include a reduced bar located in the fine dining area and a new
bar area is in the largest dining room. Due to these changes, the applicant is required to obtain
approval from the Planning Commission for a Conditional Use Permit. No new floor area has
been added so the existing 332 parking spaces do not need to be increased, but the applicant is
redesigning a portion of the parking area to add 11 additional parking spaces.
The applicant is also modifying the front entry to add a code-compliant ramp. The rest of the
improvements within the facility are to change the decor.
CONCLUSION
After conducting the public hearing and receiving testimony, staff recommends that the Planning
Commission adopt the attached Resolution No. 19-13 approving Conditional Use Permit CUP 19-5 to
allow an interior remodel to an existing banquet facility to modify the dining areas, to reduce the size of an
existing bar and to create an additional bar within the facility at 3901 Lampson Avenue.
Prepared by:
Steve Fowler
Steve Fowler
Interim Director of Community Development
Attachments:
1. Resolution No. 19-13 – A Resolution of the Planning Commission of the City of Seal
Beach, Approving Conditional Use Permit 19-5 allow an interior remodel to an existing
banquet facility to reduce the size of an existing bar and create an additional bar within
the facility at 3901 Lampson Avenue in the Recreation/ Golf (RG) Zoning Area.
2. Project architectural plans.
Page 1 of 6
RESOLUTION NO. 19-13
A RESOLUTION OF THE SEAL BEACH PLANNING
COMMISSION APPROVING CONDITIONAL USE
PERMIT 19-5 TO ALLOW AN INTERIOR REMODEL
TO AN EXISTING BANQUETTE FACILITY TO
MODIFY THE DINING AREAS, REDUCE THE SIZE
OF AN EXISTING BAR AND CREATE AN
ADDITIONAL BAR WITHIN THE FACILITY AT THE
OLD RANCH COUNTRY CLUB AT 3901 LAMPSON
AVENUE
THE PLANNING COMMISSION OF THE CITY OF SEAL BEACH DOES
HEREBY FIND AND RESOLVE AS FOLLOWS:
Section 1.Frank Herrera (“the applicant”) on behalf of Old Ranch Country Club (“the
owner”) submitted an application to the City of Seal Beach Department of Community
Development for Conditional Use Permit (CUP) 19-5 to allow an interior remodel to an existing
banquet facility to reduce the size of an existing bar and create an additional bar within the
facility at an existing country club/ golf course at 3901 Lampson Avenue (the “subject property”),
which is located in the Recreation/ Golf (RG) zoning area.
Section 2.This project is determined to be a Class 1 (Existing Facility) Categorical
Exemption pursuant to Section 15301 of the Guidelines for the California Environmental Quality
Act (Public Resources Code Section 21000 et seq.) for the permitting of an interior remodel at
an existing banquet facility where only minor modifications are required for the renovation.
Section 3.A duly noticed public hearing was held before the Planning Commission
on August 5, 2019 to consider the application for CUP 19-5. At the public hearing, the Planning
Commission received and considered all evidence presented, both written and oral, regarding
the subject application. The record of the public hearing indicates the following:
A. The subject site is four irregularly shaped parcels totaling 154.19 acres
located on the north side of Lampson Avenue east of Seal Beach Boulevard within the RG
(Recreation/ Golf) zoning area. The parcel is currently developed with a golf course, driving
range, pro-retail shop and country club with banquette facility. The subject site is surrounded by
residential uses on the east and west sides, commercial on the north, east and west and the
Los Alamitos Joint Forces Training Base to the north and the I-405 freeway to the south.
B. The proposed interior remodel to an existing banquet facility to modify the
dining areas, reduce the size of an existing bar and create an additional bar does not require
any modifications to the exterior of existing building, but the applicant is redesigning a portion of
the parking area to create 11 new parking spaces and modifying the front entry by addition of a
code-compliant ramp to comply with code requirements. The applicant is maintaining the
footprint of the existing structure with no additional square footage proposed.
Section 4.Based upon the facts contained in the record, including those stated in
the preceding Sections of this Resolution, and pursuant to Chapter 11.5.20 of the Code of the
City of Seal Beach, the Planning Commission makes the following findings:
A. The proposed interior remodel to an existing banquet facility to modify the
dining areas, reduce the size of an existing bar and create an additional bar is consistent with
Resolution No. 19-13
3901 Lampson Avenue
Page 2 of 6
the General Plan. The General Plan specifies that the Recreation/ Golf use designation
indicates that although the Old Ranch Golf Course is private with public driving ranges it is
recognized that it provides valuable open space and a recreation resource for the community.
The redesign of the interior space should provide a broad range of service needs for the
community. The golf course and country club with an alcohol license and dining amenities has
been found to be consistent with the General Plan and operated on the site for several years.
With the continued use of the existing structure as a country club with additional dining options
can offer its customers a wider range of dining experiences.
B. The proposed use complies with applicable provisions of the Municipal
Code. The Municipal Code allows for the interior remodel to an existing banquet facility to
modify dining areas, reduce the size of an existing bar and create an additional bar with
approval of a Conditional Use Permit. The existing country club will continue to operate in
compliance with all other applicable provisions of the Municipal Code.
C. The subject site is physically adequate for the proposed use. The country
club with the interior remodel to an existing banquet facility to modify the dining areas, reduce
the size of an existing bar and create an additional bar does not require alterations to the
exterior of the building and no additional parking is required, but the applicant is redesigning a
portion of the parking area to create 11 new parking spaces and modifying the front entry to
comply with code requirements. The applicant is maintaining the footprint of the existing
structure with no additional square footage proposed. The subject site is considered in
compliance with all parking requirements because the site is not expanding and the current
footprint will not expand.
D. The location, size, design, and operating characteristics of the existing
golf course and country club will not change and would be compatible with the surrounding uses
and will not adversely affect those uses or properties in the surrounding areas. The existing
building complies with the height, setback and parking requirements of the Seal Beach
Municipal Code and Public Uses land Use designation. Conditions have been imposed to
ensure the proper service of alcohol to patrons in compliance with City Council Policy 600-1
(Standard Conditions for Alcohol Related Land Uses). The hours of operation of the country
club and golf course is 6 AM to 2 AM 7 days a week and the hours that alcohol can be served
will continue to be from 10 AM to 2 AM 7 days a week as originally approved in CUP 92-14.
E. The establishment, maintenance, and operation of the existing Type 57
(On-Sale service of general alcohol to members of a private club) alcohol license would not be
detrimental to the health, safety, or welfare of persons residing or working in the vicinity. The
proposed upgrades and renovations of the facility will not require major modifications to the site
and sufficient conditions have been imposed to ensure that the use will comply with the
Performance Standards set forth in Section 11.4.10.020 of the Zoning Code and will not create
adverse impacts upon adjacent uses.
F. The subject site is a small part of the entire located which is a golf course
and the country club is where the renovations will take place. The subject site is over 500 feet
from the nearest residential property, the parking area for the country club is over 250 feet from
residential property. The subject site has operated with an alcohol license since 1966. The
applicant will be required to comply with all conditions placed on the prior business.
G. The noise levels generated by the operation of the site would not exceed
the level of background noise normally found in the area as there will be normal conversations
while dining. In the event that complaints are received in the future, the Planning Commission
reserves the right to reconsider the operation of the business and the conditions of approval.
Resolution No. 19-13
3901 Lampson Avenue
Page 3 of 6
Section 5.Based upon the foregoing, the Planning Commission hereby approves
CUP 19-5 to permit an interior remodel to an existing banquet facility to modify the dining areas,
reduce the size of an existing bar and create an additional bar within an existing country club, at
3901 Lampson Avenue, subject to the following conditions.
1. Conditional Use Permit 19-5 is approved to permit an interior remodel to an existing
banquet facility to modify the dining areas, reduce the size of an existing bar and create
an additional bar at an existing country club at 3901 Lampson Avenue.
2. The applicant shall comply with all restrictions placed upon the license by the State of
California Department of Alcoholic Beverage Control. In connection with the City
consideration of an application, the applicant must demonstrate compliance with all
restrictions placed upon the issuance of such license by the Alcoholic Beverage Control
Act, Business and Professions Code §2300 to §2600, including but not limited to Rule
61.3(a) and 61.4.
3. The applicant shall furnish the City a copy of his ABC license and a copy of the
conditions placed on the license by the Department of Alcoholic Beverage Control. This
shall be done as soon as the license is received by the applicant from the State of
California Department of Alcoholic Beverage Control.
4. The premises of the restaurant must remain in, and be operated in substantial
compliance with the plan submitted with the application and maintained on file with the
Community Development Department.
5. The hours of operation shall be limited to 6:00 AM to 2:00 AM seven days a week and
the hours for the service of alcoholic beverages is limited to 10:00 AM to 2:00 AM seven
days a week.
6. No video games or similar amusements shall be permitted on the premises.
7. There shall be no exterior advertising of any kind or type, including advertising directed
to the exterior from within, promoting or indicating the availability of alcoholic beverages.
8. It shall be the responsibility of the applicant/licensee to provide all employees that sell or
serve alcoholic beverages with the knowledge and skills that will enable them to comply
with their responsibilities under State law.
9. The knowledge and skills deemed necessary for responsible alcoholic beverage service
shall include, but not limited to the following topics and skills development:
o State Law relating to alcoholic beverages, particularly ABC and penal provisions
concerning sales to minors and intoxicated persons, driving under the influence,
hours of legal operation and penalties for violation of these laws.
o The potential legal liabilities of owners and employees of businesses dispensing
alcoholic beverages to patrons who may subsequently injure, kill, harm
themselves or innocent victims as a result of the excessive consumption of
alcoholic beverages.
Resolution No. 19-13
3901 Lampson Avenue
Page 4 of 6
o Alcohol as a drug and its effects on the body and behavior, including the
operation of motor vehicles.
o Methods of dealing with intoxicated customers and recognizing under age
customers.
10. The following organizations provide training programs, which comply with the above
criteria:
o Department of Alcoholic Beverage Control
License Education on Alcohol & Drugs (LEAD) Training
(714) 558-4101 or Leadinfo@abc.ca.gov
o Orange County Health Care Agency
Alcohol & drug Education Prevention Team (ADEPT)
Serving Alcohol Responsibly (BARCODE)
(714) 834-2860
11. Deliveries to the premises are prohibited between 10:00 PM and 7:00 AM.
12. There shall be no dumping of trash outside and/or glass bottles outside the
establishment between the hours of 10:00 PM. and 7:00 AM.
13. The establishment must comply with Chapter 7.15 “Noise” of the City of Seal Beach
Municipal Code. Should complaints be received regarding noise generated by the
establishment, the Planning Commission reserves the right to schedule this permit for
reconsideration and may require the applicant/business operator to mitigate the noise
level to comply with the provisions of Chapter 7.15.
14. Any proposed alterations or upgrades to the restaurant including, without limitation,
construction of interior tenant improvements, will require review and approval from the
City of Seal Beach Planning Division. Other City approvals may be required depending
on the extent of the proposed alterations and upgrades.
15. A modification of this CUP must be applied for when:
a. The establishment proposes to change its type of liquor license.
b. The establishment proposes to change its permitted hours of operation.
c. The establishment proposes to modify any of its current Conditions of Approval.
d. There is a substantial change in the mode or character of operations of the
establishment.
16. In the event staff determines that security problems exist on the site, the conditions of
this permit may be amended, under the procedures of the Seal Beach Municipal Code to
require the provision of additional security measures.
Resolution No. 19-13
3901 Lampson Avenue
Page 5 of 6
17. The Planning Commission reserves the right to revoke or modify this CUP if any
violation of the approved conditions occurs, harm or operational problems such as
criminal or anti-social behavior occur. Examples of harmful or operation behaviors
include, but not limited to, violence, public drunkenness, vandalism, solicitation and/or
litter.
18. The establishment shall have a public telephone listing.
19. Litter and trash receptacles shall be located at convenient locations inside the
establishment and operators of such establishments shall remove trash and debris on an
appropriate basis so as not to cause a health problem.
20. All alcoholic beverages sold in conjunction with the on-premises licensed establishment
must be consumed entirely on the premises prior to closing time. No alcoholic beverage
shall be consumed on the beach. In no circumstance shall any alcohol be passed from
patrons on the patio area to people on the beach. There shall be appropriate posting of
signs both inside and outside the licensed premises indicating that drinking outside the
licensed premises is prohibited by law.
21. An attendant will be located in the outdoor dining and seating area during business
hours when customers are occupying the area.
22. The restaurant must be maintained as a “bona fide public eating place” as defined by the
California Department of Alcoholic Beverage Control.
23. The establishment must serve a complete menu of food until thirty minutes prior to
closing time.
24. The applicant will prominently display these Conditions of Approval in a location within
the businesses’ customer area that is acceptable to the Community Development
Director.
25. Failure to comply with any of these conditions or a substantial change in the mode or
character of the residence shall be grounds for revoking or modifying this CUP approval.
26. This CUP shall not become effective for any purpose unless/until a City “Acceptance of
Conditions” form has been signed and notarized by the applicant before being returned
to the Planning Department; and until the ten (10) calendar day appeal period has
elapsed.
27. The applicant is required to obtain all required Building and Safety permits prior to tenant
improvements, construction or demolition.
28. Approval of this request shall not waive compliance with all sections of the Municipal
Code, or all other applicable City Ordinances in effect at the time of building permit
issuance.
29. This CUP shall become null and void unless exercised within one year of the date of
final approval, or such extension of time as may be granted by the Planning Commission
pursuant to a written request for extension submitted to the Community Development
Department at least ninety days prior to such expiration date.
Resolution No. 19-13
3901 Lampson Avenue
Page 6 of 6
30. The applicant must indemnify, defend, and hold harmless City, its officers, agents, and
employees (collectively “the City” hereinafter in this paragraph) from any and all claims
and losses whatsoever occurring or resulting to any and all persons, firms, or
corporations furnishing or supplying work, services, materials, or supplies in connection
with the performance of the use permitted hereby or the exercise of the rights granted
herein, and any and all claims, lawsuits or actions arising from the granting of or the
exercise of the rights permitted by this Conditional Use Permit, and from any and all
claims and losses occurring or resulting to any person, firm, corporation or property for
damage, injury or death arising out of or connected with the performance of the use
permitted hereby. Applicant’s obligation to indemnify, defend, and hold harmless the
City as stated herein shall include, but not be limited to, paying all fees and costs
incurred by legal counsel of the City’s choice in representing the City in connection with
any such claims, losses, lawsuits or actions, expert witness fees, and any award of
damages, judgments, verdicts, court costs or attorneys’ fees in any such lawsuit or
action.
PASSED, APPROVED, AND ADOPTED by the Seal Beach Planning
Commission at a meeting thereof held on August 5, 2019, by the following vote:
AYES: Commissioners _________________________________________
NOES: Commissioners _________________________________________
ABSENT: Commissioners _________________________________________
ABSTAIN: Commissioners _________________________________________
______________________________
Patricia Campbell
ATTEST: Chairperson
_________________________
Steve Fowler
Planning Commission Secretary
PROJECT DIRECTORY
TEL:
EMAIL:
CONTACT:
ARCHITECT
DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
619.299.6690
ANATIONS@DELAWIE.COM
ALAN NATIONS, ARCHITECT
TEL:
EMAIL:
CONTACT:
OWNER/ CLIENT
CLUBCORP
3030 LBJ FREEWAY, SUITE 600
DALLAS, TX 75234
214.538.7220
TOM.DEVLIN@CLUBCORP.COM
TOM DEVLIN
SENIOR VICE PRESIDENT
TEL:
EMAIL:
CONTACT:
APPLICANT
DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
619.299.6690
ANATIONS@DELAWIE.COM
ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
PROJECT SITE
NORTH
DESCRIPTION of PROPOSED PROJECT
Old Ranch Country Club Interior T.I.
The existing Clubhouse building is primarily a single-story structure, 42,000 SF in area plus a
partial basement of 11,195 SF and second story level of 3,239 SF. The area of this project’s
scope of work is limited to the single-story interior portion of the structure in the form of 10,594 SF
of tenant improvements (T.I.) plus replacement of an existing non-compliant exterior ramp and
surrounding floor finish materials associated with the building’s front entry area. No new building
additions are proposed. No work in the lower partial basement level or second level portions of
the structure is proposed. No change to the building’s exterior façade is proposed. No change to
existing on-site parking or site access is proposed.
Interior T.I. consists of selective demolition of non-bearing walls and partitions, doors and built-in
components including bar and seating elements, floor and wall finishes, plumbing and lighting
fixtures of public “assembly” spaces consisting of reception, dining, banquette and connecting
corridor spaces.
Interior T.I. new work within the spaces noted above include construction of new walls, ceilings
and soffits, doors and storefront systems, electrical upgrades, mechanical & plumbing system
modifications, built-in dining seating and bars. Cosmetic improvements includes new flooring,
wall coverings, millwork & general painting throughout the scope of work area.
Limited exterior work involving the building’s front entry includes new compliant pedestrian entry
ramp system, hardscape finish upgrades in the form of new stone paving and associated
landscape modifications in the immediate area.
PROJECT AREA SUMMARY
IN SCOPE SPACES:
RECEPTION - #101 127 SF
DINING FOYER - #102 722 SF
CHILDREN’S PLAY ROOM - #103 530 SF
SERVICE - #104 222 SF
MAIN DINING & BAR- #105/106 2,898 SF
FAMILY DINING - #107 1,242 SF
TERRACE FOYER - #108 215 SF
FINE DINING & BAR - #109/110 951 SF
PRIVATE DINING - #111 593 SF
CORRIDOR – A 603 SF
CORRIDOR – B 562 SF
CORRIDOR – C 360 SF
TOTAL 10,594 SF
ADDRESS: 3901 LAMPSON AVENUE
SEAL BEACH, CA 90740
APN:130-012-54, 130-012-55, 130-012-56, 130-012-58
LEGAL DESCRIPTION:
IN THE CITY OF SEAL BEACH COUNTY OF ORANGE, STATE OF CALIFORNIA BEING
PARCEL 1 OF PARCEL MAP FILED IN BOOK 79, PAGE 49, OF PARCEL MAPS, IN THE
OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, A PORTION OF PARCEL 1
OR PARCEL MAP FILED IN BOOK 16, PAGE 14 OF PARCEL MAPS, IN THE OFFICE OF
THE COUNTY RECORDER OF SAID COUNTY, AND AN UNDIVIDED PORTION OF THE
NE 1/4 OF SECTION 31, TOWNSHIP 4 SOUTH, RANGE 11 WEST, SAN BERNARDINO
MERIDIAN, IN THE RANCHO LOS ALAMITOS, AS PER THE MAP FILED IN BOOK 14,
PAGE 31 OF DEEDS, IN THE OFFICE OF SAID COUNTY RECORDER.
CODE ENFORCEMENT
JURISDICTION: CITY OF SEAL BEACH
EXISTING USE: COUNTRY CLUB MEMBERS HOUSE
PROPOSED USE: NO CHANGE IN USE
YEAR CONSTRUCTED: 1967
ZONING INFO: RG, RECREATIONAL GOLF
SITE AREA: 154.19 ACRES
F.A.R.: -
POTENTIAL HISTORIC RESOURCE: NO
DESIGNATED HISTORIC SITE NO
SPECIAL APPROVALS: CONDITIONAL USE PERMIT
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:44 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 COVER SHEET
G-01
05/09/2019
OLD RANCH COUNTRY CLUB
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740
CONDITIONAL USE PERMIT -05/09/2019
PROJECT SUMMARYPROJECT DATA
VICINITY MAP
PROJECT SHEET INDEX - CUP
GENERAL
G-01 COVER SHEET
ARCHITECTURAL
AS-11 EXISTING SITE PLAN
AS-12 PROPOSED SITE PLAN
A-11 LOWER LEVEL - EXISTING FLOOR PLAN
A-12 MAIN LEVEL - OVERALL EXISTING FLOOR PLAN
A-13 MAIN LEVEL - ENLARGED EXISTING FLOOR PLAN
A-14 MAIN LEVEL - ENLARGED EXISTING FLOOR PLAN
A-15 SECOND FLOOR - EXISTING FLOOR PLAN
A-21 MAIN LEVEL - OVERALL PROPOSED FLOOR PLAN
A-22 MAIN LEVEL - ENLARGED PROPOSED FLOOR PLAN
A-23 MAIN LEVEL - ENLARGED PROPOSED FLOOR PLAN
A-31 EXTERIOR ELEVATIONS
A-32 EXTERIOR ELEVATIONS
A-33 EXTERIOR ELEVATIONS
A-34 EXTERIOR ELEVATIONS
REV
NO.
DATE
ISSUED REASON
L A M P S O N A V E N U E LAM PSO N AVENUEA11
A10
A9
A8
A8
A12
A12
A13
A5
19
14
16
16
15
12
12
11
9
10
9
7
3
7
8
8
4
6
8
8
7
7
5
10
6
90
4
4
A9
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORK
A8
A9
A8A8A8A8A8 A8
A9
A9
A1
A19
A18
A7
A7
A7
TYP
A15
A2
A3
A4
A6
A8A8
A8
A8A8
A23
TYP
A17
TYP
A17
TYP
A16
TYP
A16
TYP
A15
TYP
A15 A14
TYP
A15
SCOPE OF WORK
AREA = 10,594 SF MAIN LEVEL AREA = 42,000 SF (NO CHANGE)
TOTAL AREA = 55,520 SF (NO CHANGE)
SITE AREA = 154.19 ACRES (NO CHANGE)
LEGEND
ACCESSIBLE ROUTE
LIMIT OF WORK
[E] SITE LIGHTING BOLLARDS
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:39 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 EXISTING SITE
PLAN
AS-11
05/09/2019
1" = 30'-0"A1 A-3.01
A1 EXISTING SITE PLAN
0'30'15'60'
SCALE: 1" = 30'
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
A1 AREA OF PROPOSED WORK (10,594 SF)
A2 MAIN MEMBER ENTRY
A3 BANQUET HALL ENTRY
A4 ENTRY TO CART STORAGE
A5 CLUB-SITE ENTRANCE
A6 SNACK BAR WALK-UP WINDOW
A7 PASSANGER DROP-OFF
A8 [E] ACCESSIBLE PARKING SPACES
A9 [E] ACCESSIBLE PATH OF TRAVEL
A10 [E] TRASH ENCLOSURE
A11 [E] SECURITY STATION
A12 [E] LAKE
A13 [E] GOLF COURSE
A14 [E] FIRE WATER CONTROL VALVES
A15 [E] CURBED LANDSCAPE ISLAND
A16 [E] SITE LIGHTING
A17 [E] CONCRETE WHEELSTOPS
A18 [E] POOL
A19 [E] WEDDING GAZEEBO
A23 [E] ACCESSIBLE RAMP TO MAIN MEMBER ENTRY
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
EXISTING PARKING DATA
TOTAL EXISTING PARKING SPACES 332
ACCESSIBLE PARKING SPACES
REQUIRED 8
PROVIDED 15
L A M P S O N A V E N U E LAM PSO N AVENUEA11
A10
A22
A21
A12
A12
A13
A5
A24
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORKLIMIT OF WORK19
14
17
16
15
12
12
11
9
10
9
7
3
7
8
8
7
7
8
8
7
7
5
10
6
90
4
4LIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORK
A22
A21
A22
A21A21 A21A21
A21
A21
A22
A2
A6
A1
A4
A19
A18
A7
A7
A7
A3
TYP
A20
TYP
A20
TYP
A16
TYP
A16
TYP
A15
TYP
A15
TYP
A15
TYP
A15
A14
SCOPE OF WORK
AREA = 10,594 SF MAIN LEVEL AREA = 42,000 SF (NO CHANGE)
TOTAL AREA = 55,520 SF (NO CHANGE)
SITE AREA = 154.19 ACRES (NO CHANGE)
LEGEND
ACCESSIBLE ROUTE
LIMIT OF WORK
[E] SITE LIGHTING BOLLARDS
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:44 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 PROPOSED
SITE PLAN
AS-12
05/09/2019
1" = 30'-0"A1 A-3.01
A1 PROPOSED SITE PLAN
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
A1 AREA OF PROPOSED WORK (10,594 SF)
A2 MAIN MEMBER ENTRY
A3 BANQUET HALL ENTRY
A4 ENTRY TO CART STORAGE
A5 CLUB-SITE ENTRANCE
A6 SNACK BAR WALK-UP WINDOW
A7 PASSANGER DROP-OFF
A10 [E] TRASH ENCLOSURE
A11 [E] SECURITY STATION
A12 [E] LAKE
A13 [E] GOLF COURSE
A14 [E] FIRE WATER CONTROL VALVES
A15 [E] CURBED LANDSCAPE ISLAND
A16 [E] SITE LIGHTING
A18 [E] POOL
A19 [E] WEDDING GAZEEBO
A20 [E] CONCRETE WHEELSTOPS TO BE REINSTALLED
A21 RESTRIPED ACCESSIBLE PARKING SPACE
A22 RESTRIPED ACCESSIBLE PATH OF TRAVEL
A24 [N] ACCESSIBLE RAMP TO MAIN MEMBER ENTRY
0'30'15'60'
SCALE: 1" = 30'
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
GENERAL NOTES
1. EXISTING PARKING LOT TO BE FULLY RESTRIPED.
PROPOSED PARKING DATA
TOTAL PROPOSED PARKING SPACES 343
ACCESSIBLE PARKING SPACES
REQUIRED 8
PROVIDED 8
1
1 2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
DD
CC
BB
AA
CART BARN
112
STORAGE
113
BAG STORAGE
116
UTILITY
117
COOLER
118
SNACK BAR
119
WOMEN'S
RESTROOM
120
MEN'S
RESTROOM
121
STORAGE
122
OFFICE
114
CLUB REPAIR
115
UP
UP
A4
A6
LOWER LEVEL AREA = 11,195 SF (NO CHANGE)
LEGEND:
(E) WALL PER PLAN
AREA NOT INCLUDED IN SCOPE OF WORK
[NO WORK PROPOSED]
LIMIT OF WORK
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:44:57 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 LOWER LEVEL
- EXISTING
FLOOR PLAN
A-11
05/09/2019
1/8" = 1'-0"A1 A-3.01
B1 LOWER LEVEL - EXISTING FLOOR PLAN (NO WORK PROPOSED. FOR REFERENCE ONLY)
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
A4 ENTRY TO CART STORAGE
A6 SNACK BAR WALK-UP WINDOW
SCALE: 1/8" = 1'-0"
0 4'-0"8'-0"16'-0"
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
KEY PLAN
GENERAL NOTES
1. ONLY WORK ON THIS LEVEL INVLOVES PLUMBING CONNECTIONS BETWEEN
EXISTING AND NEW WORK AOBVE.
DN
DN
UP
UP
UP
UP
UP
UP
UP
UP
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
FF
EE
DD
CC
BB
AA
10.1
10.1 11.1
11.1
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORK(E) DINING
(E) BOARDROOM
(E) SERVICE
(E) DINING
(E) DINING(E) MEN'S
CARDROOM
(E) BAR
(E) WEST TERRACE
(E) NORTH
TERRACE
(E) CORRIDOR
(E) ENTRY
(E) RECEPTION
(E) BANQUET HALL
(E) PRE-FUNCTION AREA
(E) PRO SHOP
(E) OFFICES
(E) KITCHEN
(E) EXERCISE ROOM
(E) WOMEN'S
LOCKER ROOM
(E) WOMEN'S RESTROOM
(E) OFFICE
(E) MEN'S LOCKER ROOM
(E) MEN'S RESTROOM
(E) WOMEN'S
RESTROOM
(E) MEN'S
RESTROOM
(E) STORAGE AREA
(E) ELECTRICAL
ROOM
(E) CORRIDOR
(E) WOMEN'S
RESTROOM
(E) MEN'S
RESTROOM
(E) OFFICE
(E) BRIDAL
SUITE
(E) ELEVATOR
(E) STORAGE
(E) STORAGE (E) BAR
(E) STORAGE
(E) RESTROOMS
(E) SERVICE
RAMP
DN
(E) TELCOMM
MAIN LEVEL AREA = 42,000 SF (NO CHANGE)
LEGEND:
(E) WALL PER PLAN
AREA NOT INCLUDED IN SCOPE OF WORK
[NO WORK PROPOSED]
LIMIT OF WORK
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:01 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 MAIN LEVEL -
OVERALL
EXISTING
FLOOR PLAN
A-12
05/09/2019
1/16" = 1'-0"A1 A-3.01
B1 MAIN LEVEL - OVERALL EXISTING FLOOR PLAN
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
SCALE: 1/16" = 1'-0"
0 8'-0"16'-0"32'-0"
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
DN
DN
UP
UP
4
4
5
5
6
6
7
7
8
8
9
9
10
10
FF
EE
DD
CC
10.1
10.1
LIMIT OF WORK LIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORK
LIMIT OF WORKLIMIT OF WORK
(E) BOARDROOM
(E) SERVICE
(E) CORRIDOR
(E) ENTRY
(E) RECEPTION
(E) OFFICES
(E) KITCHEN
(E) MEN'S RESTROOM
(E) WOMEN'S
RESTROOM
(E) MEN'S
RESTROOM
(E) CORRIDOR
A25
RAMP
DN
LEGEND:
(E) WALL PER PLAN
AREA NOT INCLUDED IN SCOPE OF WORK
[NO WORK PROPOSED]
LIMIT OF WORK
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:04 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 MAIN LEVEL -
ENLARGED
EXISTING
FLOOR PLAN
A-13
05/09/2019
1/8" = 1'-0"A1 A-3.01
A1 MAIN LEVEL - ENLARGED EXISTING FLOOR PLAN
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
A25 [E] WOOD ENTRY DOORS
SCALE: 1/8" = 1'-0"
0 4'-0"8'-0"16'-0"
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
KEY PLAN
UP
UP
UP
DN
UP
UP
3
3
4
4
5
5
6
6
7
7
8
8
9
9
DD
CC
BB
AA
LIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORKLIMIT OF WORK
LIMIT OF WORK
(E) DINING
(E) SERVICE
(E) DINING
(E) DINING(E) MEN'S
CARDROOM
(E) BAR
(E) WEST TERRACE
(E) NORTH TERRACE
(E) CORRIDOR
(E) WOMEN'S RESTROOM
(E) PRO SHOP
A27
A28
A26
(E) TELCOMM
LEGEND:
(E) WALL PER PLAN
AREA NOT INCLUDED IN SCOPE OF WORK
[NO WORK PROPOSED]
LIMIT OF WORK
PROJ. NO.
Sheet Title
Sheet No.ALL IDEAS, DESIGNS AND ARRANGEMENTS INDICATED ON THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND ARE TO BE USED IN CONNECTION WITH THIS SPECIFIC PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT. THERE SHALL BE NOCHANGES OR DEVIATION FROM THE DRAWINGS OR ACCOMPANYING SPECIFICATION WITHOUT THE EXPRESSED CONSENT OF THE ARCHITECT.A
1 2 3 4
B
C
D
APPLICANT: DELAWIE
1515 MORENA BLVD.
SAN DIEGO, CA 92110
TEL: 619.299.6690
EMAIL: ANATIONS@DELAWIE.COM
CONTACT: ALAN NATIONS, ARCHITECT
AGENT FOR OWNER/CLIENT
1515 Morena Blvd.
San Diego, CA 92110
(619) 299-6690
delawie.com
C
D
B
5
1 2 3 4 5
5/3/2019 10:45:07 AM18195OLD RANCH COUNTRY CLUB
CONDITIONAL USE PERMIT
3901 LAMPSON AVENUE,
SEAL BEACH, CA 90740 MAIN LEVEL -
ENLARGED
EXISTING
FLOOR PLAN
A-14
05/09/2019
1/8" = 1'-0"A1 A-3.01
A1 MAIN LEVEL - ENLARGED EXISTING FLOOR PLAN
SHEET KEYNOTES
NUMBER SHEET NOTE TEXT
A26 [E] FIRE TABLE
A27 [E] LIFT
A28 [E] FIREPLACE
SCALE: 1/8" = 1'-0"
0 4'-0"8'-0"16'-0"
TRUE
NORTH
PLAN
NORTH
REV
NO.
DATE
ISSUED REASON
KEY PLAN