HomeMy WebLinkAboutCC AG PKT 2010-02-22 #IAGENDA STAFF REPORT
DATE: February 22, 2010
TO: Honorable Mayor and City Council
THRU: David N. Carmany, City Manager
FROM: Jill R. Ingram, Assistant to the City Manager
SUBJECT: McGAUGH POOL STATUS UPDATE
SUMMARY OF REQUEST:
It is recommended that the City Council:
1. Receive and file the report; and
2. Provide direction to staff as appropriate regarding the continued
operation of the McGaugh School community pool, with specific
direction regarding funding the recommended installation of a
"French drain."
BACKGROUND:
On February 11, 2010 staff met with Los Alamitos School District officials to
discuss ongoing issues with the McGaugh pool. As the school district is in the
process of demobilizing from their current modernization process on the campus,
they have expressed immediate concerns in the ongoing leak from the pool and
saturation of nearing soil.
As the District nears the end of their project, they have a desire to convert the
existing tennis courts into 63 additional parking spots to address the lack of
adequate parking. In the process of planning this conversion, the District
contracted a geotechnical distress evaluation from a geotechnical /environmental
firm regarding the tennis court slab adjacent to the swimming pool to evaluate the
condition of the subsurface soils. Attached is a copy of the limited geotechnical
distress evaluation by TGR Geotechnical, Inc.
In an effort to keep the McGaugh pool operating at its current level, and to
address the concern of a future sink hole issue related to ongoing soil saturation
within the tennis court slab adjacent to the swimming pool, the geotechnical
project engineer is recommending the placement of a "French drain" adjacent to
the northwest end of the pool deck. The "French drain" would outlet water runoff
to a drainage area near the sports field.
Agenda Item
Page 2
On Tuesday, February 16th, our City Engineer and staff met onsite with the
District's modernization contractor. Our City Engineer is looking at other options
to re- direct the outlet water runoff to a drainage area that will not affect the sport
fields, and will provide an update at the Council meeting.
The District is gathering a more accurate cost estimate, however, the rough
estimate for this temporary solution to keep the pool open is approximately
$125,000. The District is requesting the City's assistance to fund the requested
"French drain" installation.
FINANCIAL IMPACT:
While the District is gathering a more accurate cost estimate, the rough estimate
for this temporary solution to keep the pool open is approximately $125,000.
RECOMMENDATION:
It is recommended that the City Council:
1. Receive and file the report; and
2. Provide direction to staff as appropriate regarding the continued
operation of the McGaugh School community pool, with specific
direction regarding funding the recommended installation of a
"French drain."
SUBMITTED BY:
Q�LL'�R - C61 erwn
Jill . Ingram,
Assistant to the City anager
NOTED AND APPROVED:
David N. Car any, City Manager
Prepared by: Tim Kelsey, Community Services Supervisor
Attachments:
A. Limited Geotechnical Distress Investigation of Tennis Courts Northwest Side of Swimming Pool
A
A_J ilk
TGR GEOTECHNICAI_, INC.
GEOTECHNICAL•
January 5, 2010
Los Alamitos Unified School District
10652 Reagan Street
Los Alamitos, CA 90720
Fax: (562) 799 -4599
Attention: Mr. Larry Atherton
MATERIALS • ENVIRONMENTAL
Project No. 09 -2598
Subject: limited Geotechnical Distress Investigation, Tennis Courts Northwest Side of Swimming Pool,
McGaugh Elementary School, 1698 Bolsa Avenue, Seal Beach, California.
Dear Mr. Atherton,
In accordance with your request, TGR Geotechnical, Inc. (TGR) has completed the limited geotechnical
distress evaluation of the Tennis Court Slab at the subject site. The work was performed in accordance with
our proposal dated December 16, 2009 and your subsequent authorization to proceed. It is our
understanding that cracks had developed within the tennis court slab adjacent to the swimming pools. The
purpose of the current investigation is to evaluate the condition of the subsurface soils supporting the subject
slab and provide mitigation recommendation.
SCOPE OF SERVICES
The following were performed at the subject site.
1. Site reconnaissance.
2. Concrete coring at five (5) locations within the tennis court.
3. Sampling and Iogging five (5) hand auger borings to a depth of approximately 5 feet below
existing slab.
4. Laboratory testing of selected samples to include: in -situ moisture density and optimum moisture
content.
5. Preparation of this limited geotechnical distress investigation report, summarizing current sub-
surface soil conditions, findings, and presenting mitigation measures.
SITE EXPLORATION
On December 22, 2009 field exploration was performed by coring the concrete slab at five (5) different
locations, and drilling to a depth ranging from approximately 5 feet to 6 feet below bottom of existing slab,
and obtaining representative soil samples. The borings were backfilled with cuttings. Patching the borings
was not within the scope of services, and was performed by others. The approximate locations of the borings
are shown on the Boring Location Map, Plate 1.
Relatively undisturbed /grab samples of soils were extracted using modified California Ring Sampler (CRS),
3 -inch outside diameter, and 2.42 -inch inside diameter. All samples were secured in moisture- resistant bags
as soon as taken to minimize the loss of field moisture while being transported to the laboratory and waiting
to be tested. The borings were backfilled with excess excavated soils.
3037 S. Harbor Boulevard - Santa Ana - CA 92704 - Ph.: 714.641.7189 - Fax: 714.641.7190
09 -2598
SUBGRADE SOIL
The sub -grade soil generally consists of dark brown to reddish brown silty sand. The descriptions of the earth
materials encountered, along with the densities and moisture contents, are presented in the table below. Soil
collapse and erosion was observed in boring B -1 from the subgrade level to approximately 2 feet below the
bottom of the tennis court slab.
LABORATORY TESTING
Moisture and Density Determination Tests: Moisture content and dry density determinations were
performed on relatively undisturbed samples obtained from the test borings. The results of these tests are
presented below. Where applicable, only moisture content was determined from "undisturbed" or
If "& 1 4 4 enmr%lce
uaw uvu v
Sample
Location
Soil Description
p
Moisture ( %}
Dry
Density
(pc*
Relative
Compaction
N
B -1 @ SG
No Recovery. Voids and Free Standing
Water to 2 ft below Grade.
-
-
-
B -1 @ 4'
Dark brown silty SAND
17.5
-
-
B -2 @ SG
Reddish brown silty SAND
12.7
111.9
88
B -2 @ 4'
Reddish brown silty SAND
10.9
120.2
94
B -3 @ SG
Dark brown silty SAND
10.0
112.5
88
B -3 @ 4'
Reddish brown silty SAND
9.8
120.0
94
BA @ SG
Dark brown silty SAND
18.1
109.8
86
B-4 @ 4'
Reddish brown silty SAND
12.5
119.4
94
B -5 @ SG
Reddish brown silty SAND
9.3
110.1
86
B -5 @ 3'
Dark brown silty SAND
9.6
113.0
89
B -5 @ 5'
Brown Silty SAND
11.8
120.8
95
Maximum Density Tests: The maximum dry density and optimum moisture content of typical materials were
determined in accordance with ASTM Test Method D1557. The-results of these tests are presented in the
a_..a 4 4-- .,.,A Gn 4,6 4_61n hclmm
acat
Maximum Dry Optimum
Sample
Sample Description
Density moisture content
Location
(pcf) N
B-4 (0 to 4')
Silty Sand 127.5 9.5
EVALUATION AND RECOMMENDATION
Based on our field observation, encountered voids and water, in -situ moisture content, and change in
moisture content with lateral and vertical distance it is TGR's professional opinion that the encountered water
is a result of leakage from the adjacent swimming pools.
Evidence of water and soil erosion /collapse was present in boring B- ladvanced at the southwest comer of
the tennis court in the most distress area located adjacent to the swimming pools. The erosion /collapse and
free standing water extended to approximately 2 feet below slab bottom. The subsurface molture content is
M EL
AM
, *4
TGR GEOTECHNICAL, INC.
09 -2598
significantly above optimum moisture content in the upper 4 feet where adjacent to the swimming pools and
at the southwest corner of the subject tennis court. The subsurface relative compaction varies from 86
percent to 88 percent in the upper 2 feet of the subgrade, with the exception of boring B -1.
In order to protect the upper 2 to 3 feet of subgrade from additional seepage water we recommend placing a
"French - Drain" at approximately 2 feet below existing grade adjacent to the existing swimming pools. The
drain pipe shall be perforated and wrapped in' /, -inch crushed aggregate. The recommended location of the
drain is presented on Plate 1, attached. The drain should outlet to an approved drainage area.
The slab may be leveled using void filling /compaction grouting. The grout points shall be in a grid like pattern
and shall be spaced at 4 feet on center in two- directions. The recommended limit of the grout points is
presented on Plate 1, attached. The maximum depth of compaction grouting should be 10 feet below existing
grade, and the grout shall be pumped at 2 feet vertical intervals. The grouting operation shall be performed
under the full time observation of TGR to ensure that the intent of this report and the recommendations
presented in this report are implemented during construction.
CLOSURE
This report has been prepared for the exclusive use- of Los Alamitos Unified School District and their
design consultants relative to the subject project. No portion of this report may be used by other parties or
for other purposes.
The findings contained in this report are based upon the information obtained from the limited number of
test borings and the results of laboratory testing and engineering analysis. As part of the engineering
analysis, it has been assumed, and is expected, that the geotechnical conditions, which exist across the
site, are similar to those encountered in the exploratory borings drilled. However, no warranty is expressed
or implied as to the conditions at locations or depths other than those excavated.
Our findings were obtained in accordance with generally accepted current professional principles and local
practice in geotechnical engineering. We make no other warranty, either express or implied.
This report is subject to review by the controlling authorities for the project. We thank you for this
opportunity to be of service to you on this project. If you have any questions regarding this report, please
do not hesitate to call this office.
Respectfully submitted,
TGR GEOTECHNICAL, INC.
J.
No C070367
It EXP. 9.30.10
aher J. Yazeji, PE, 70387 ;
Senior Project Engineer <' % ?`` �'�vl� - r•�';.
Attachment: Plate 1— Coring Location Map
Distribution: (4) Addressee
A IL
An EL
-3- e. J ®t
TGR GEOTECHNICAL, INC.